Echocardiographic Parameters of Patent Ductus Arteriosus in Preterm Infants

被引:14
|
作者
Khositesth, A. [1 ]
Nuntnarumit, P. [1 ]
Chongkongkiat, P. [1 ]
机构
[1] Mahidol Univ, Dept Pediat, Fac Med, Ramathibodi Hosp, Bangkok 10400, Thailand
关键词
Diastolic function; Echocardiography; Left ventricular dimension; Patent ductus arteriosus; Preterm; Systolic function; LEFT-VENTRICULAR OUTPUT; VOLUME; DOPPLER;
D O I
10.1007/s13312-011-0127-5
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To analyze cardiovascular parameters by echocardiography in preterm infants with patent ductus arteriosus (PDA). Setting: Tertiary-care pediatric university hospital. Design: Cross-sectional, hospital-based study. Participants: 58 preterm infants, gestational age less than 33 weeks. Measurements: A complete 2-dimension, M-mode, color doppler echocardiography was performed in each preterm infant at approximately 48 hours of life. Results: Each preterm was categorized into hemodynamically significant PDA (hsPDA) (n=17, 29.3%), non-hemodynamically significant PDA (non-hsPDA) (n=12, 20.7%), and no PDA (non-PDA) (n=29, 50%). Gestational age (29.4 +/- 1.2 wk) and birth weight (1237 +/- 358 g) of infants in hsPDA were significantly lower than those in non-PDA group (30.8 +/- 1.3 wk, 1543 +/- 361 g, P = 0.001), as compared to those in the non-hsPDA group (29.5 +/- 2.3 wk, 1296 +/- 462 g). Cardiovascular parameters including left atrium/aorta ratio, left atrium volume index, left ventricular dimensions and volumes, stroke volume, and cardiac output in hs-PDA were significantly greater than those in non-hsPDA and non-PDA. LV systolic and diastolic functions were not significantly different in each group. LV global function in hsPDA (0.34 +/- 0.13) was significantly lower than that in non-PDA (0.45 +/- 0.13, P = 0.01). Conclusions: In preterm infants with hsPDA, there was a volume load of the left heart causing increased stroke volume and cardiac output. The hsPDA could be detected by echocardiography even in the first 48 hours. The left atrial volume index may be a better indicator of the volume load of the heart.
引用
收藏
页码:773 / 778
页数:6
相关论文
共 50 条
  • [11] Patent ductus arteriosus in preterm infants
    Arun Sasi
    Ashok Deorari
    [J]. Indian Pediatrics, 2011, 48 : 301 - 308
  • [12] Interparametric Correlation Between Echocardiographic Markers in Preterm Infants With Patent Ductus Arteriosus
    Arvind Sehgal
    Samuel Menahem
    [J]. Pediatric Cardiology, 2013, 34 : 1212 - 1217
  • [13] Interparametric Correlation Between Echocardiographic Markers in Preterm Infants With Patent Ductus Arteriosus
    Sehgal, Arvind
    Menahem, Samuel
    [J]. PEDIATRIC CARDIOLOGY, 2013, 34 (05) : 1212 - 1217
  • [14] Echocardiographic parameters predicting spontaneous closure of ductus arteriosus in preterm infants
    He, Minyu
    Yang, Zhengchun
    Gan, Tian
    Tang, Jing
    Ran, Suzhen
    Zhang, Kun
    [J]. FRONTIERS IN PEDIATRICS, 2023, 11
  • [15] PATENT DUCTUS-ARTERIOSUS IN PRETERM INFANTS
    BURNARD, ED
    THOMAS, DB
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 1980, 2 (08) : 461 - 462
  • [16] Management of the patent ductus arteriosus in preterm infants
    Mitra, Souvik
    Weisz, Dany
    Jain, Amish
    't Jong, Geert
    [J]. PAEDIATRICS & CHILD HEALTH, 2022, 27 (01) : 63 - 63
  • [17] PATENT DUCTUS-ARTERIOSUS IN PRETERM INFANTS
    YU, VYH
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 1980, 2 (04) : 175 - 176
  • [18] Repeatability of echocardiographic parameters to evaluate the hemodynamic relevance of patent ductus arteriosus in preterm infants: a prospective observational study
    Christoph E. Schwarz
    Antonio Preusche
    Winfried Baden
    Christian F. Poets
    Axel R. Franz
    [J]. BMC Pediatrics, 16
  • [19] Repeatability of echocardiographic parameters to evaluate the hemodynamic relevance of patent ductus arteriosus in preterm infants: a prospective observational study
    Schwarz, Christoph E.
    Preusche, Antonio
    Baden, Winfried
    Poets, Christian F.
    Franz, Axel R.
    [J]. BMC PEDIATRICS, 2016, 16
  • [20] PRECORDIAL CONTRAST ECHOCARDIOGRAPHIC DETECTION OF PATENT DUCTUS-ARTERIOSUS IN SMALL PRETERM INFANTS
    ZEDNIKOVA, M
    BAYLEN, BG
    YOSHIDA, Y
    EMMANOUILIDES, GC
    [J]. PEDIATRIC CARDIOLOGY, 1982, 2 (04) : 271 - 275