Echocardiographic Parameters of Patent Ductus Arteriosus in Preterm Infants

被引:14
|
作者
Khositesth, A. [1 ]
Nuntnarumit, P. [1 ]
Chongkongkiat, P. [1 ]
机构
[1] Mahidol Univ, Dept Pediat, Fac Med, Ramathibodi Hosp, Bangkok 10400, Thailand
关键词
Diastolic function; Echocardiography; Left ventricular dimension; Patent ductus arteriosus; Preterm; Systolic function; LEFT-VENTRICULAR OUTPUT; VOLUME; DOPPLER;
D O I
10.1007/s13312-011-0127-5
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To analyze cardiovascular parameters by echocardiography in preterm infants with patent ductus arteriosus (PDA). Setting: Tertiary-care pediatric university hospital. Design: Cross-sectional, hospital-based study. Participants: 58 preterm infants, gestational age less than 33 weeks. Measurements: A complete 2-dimension, M-mode, color doppler echocardiography was performed in each preterm infant at approximately 48 hours of life. Results: Each preterm was categorized into hemodynamically significant PDA (hsPDA) (n=17, 29.3%), non-hemodynamically significant PDA (non-hsPDA) (n=12, 20.7%), and no PDA (non-PDA) (n=29, 50%). Gestational age (29.4 +/- 1.2 wk) and birth weight (1237 +/- 358 g) of infants in hsPDA were significantly lower than those in non-PDA group (30.8 +/- 1.3 wk, 1543 +/- 361 g, P = 0.001), as compared to those in the non-hsPDA group (29.5 +/- 2.3 wk, 1296 +/- 462 g). Cardiovascular parameters including left atrium/aorta ratio, left atrium volume index, left ventricular dimensions and volumes, stroke volume, and cardiac output in hs-PDA were significantly greater than those in non-hsPDA and non-PDA. LV systolic and diastolic functions were not significantly different in each group. LV global function in hsPDA (0.34 +/- 0.13) was significantly lower than that in non-PDA (0.45 +/- 0.13, P = 0.01). Conclusions: In preterm infants with hsPDA, there was a volume load of the left heart causing increased stroke volume and cardiac output. The hsPDA could be detected by echocardiography even in the first 48 hours. The left atrial volume index may be a better indicator of the volume load of the heart.
引用
收藏
页码:773 / 778
页数:6
相关论文
共 50 条
  • [1] Echocardiographic parameters of patent ductus arteriosus in preterm infants
    A. Khositseth
    P. Nuntnarumit
    P. Chongkongkiat
    [J]. Indian Pediatrics, 2011, 48 : 773 - 778
  • [2] Patent ductus arteriosus in preterm infants: Early echocardiographic parameters
    Mannarino, S
    Fufi, EM
    De Sanctis, M
    Schena, F
    Polito, E
    Savoia, M
    Mosca, F
    [J]. PEDIATRIC RESEARCH, 2004, 55 (04) : 52A - 52A
  • [3] Echocardiographic Evaluation of Patent Ductus Arteriosus in Preterm Infants`
    Arlettaz, Romaine
    [J]. FRONTIERS IN PEDIATRICS, 2017, 5
  • [4] ECHOCARDIOGRAPHIC ASSESSMENT OF PATENT DUCTUS-ARTERIOSUS SHUNTING IN PRETERM INFANTS
    LAIRD, WP
    FIXLER, DE
    [J]. CLINICAL RESEARCH, 1975, 23 (01): : A58 - A58
  • [5] Narrative Review on Echocardiographic Evaluation of Patent Ductus Arteriosus in Preterm Infants
    Singh, Yogen
    Chan, Belinda
    Noori, Shahab
    Ramanathan, Rangasamy
    [J]. JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2024, 11 (07)
  • [6] ECHOCARDIOGRAPHIC DIAGNOSIS OF PATENT DUCTUS-ARTERIOSUS (PDA) IN PRETERM INFANTS
    PFEFFERKORN, JR
    [J]. KLINISCHE PADIATRIE, 1988, 200 (02): : 145 - 145
  • [7] Comparison of Perfusion Index and Echocardiographic Parameters in Preterm Infants with Hemodynamically Significant Patent Ductus Arteriosus
    Buyukeren, Melek
    Yigit, Sule
    Aykan, Hayrettin Hakan
    Karagoz, Tevfik
    Celik, Hasan Tolga
    Yurdakok, Murat
    [J]. JOURNAL OF CLINICAL NEONATOLOGY, 2021, 10 (01) : 11 - 18
  • [8] Patent Ductus Arteriosus in Preterm Infants
    Chen, Jia-Yuh
    [J]. PEDIATRICS AND NEONATOLOGY, 2012, 53 (05): : 275 - 275
  • [9] Patent Ductus Arteriosus in Preterm Infants
    Sasi, Arun
    Deorari, Ashok
    [J]. INDIAN PEDIATRICS, 2011, 48 (04) : 301 - 308
  • [10] Patent Ductus Arteriosus in Preterm Infants
    Benitz, William E.
    [J]. PEDIATRICS, 2016, 137 (01)