Mapping of explosive contamination using GC/chemiluminescence and ion mobility spectrometry techniques

被引:5
|
作者
Miller, CJ [1 ]
Glenn, DF [1 ]
Hartenstein, SD [1 ]
Hallowell, SF [1 ]
机构
[1] Lockheed Martin Idaho Technol, Idaho Natl Engn & Environm Lab, Idaho Falls, ID USA
来源
ENFORCEMENT AND SECURITY TECHNOLOGIES | 1998年 / 3575卷
关键词
explosive; manufacturer; courier; IED; IMS;
D O I
10.1117/12.335005
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Recent efforts at the Idaho National Engineering and Environmental Laboratory (INEEL) have included mapping explosive contamination resulting from manufacturing and carrying improvised explosive devices (IEDs). Two types of trace detection equipment were used to determine levels of contamination from designated sampling areas. A total of twenty IEDs were constructed: ten using TNT and ten using C-4. Two test scenarios were used. The first scenario tracked the activities of a manufacturer who straps the device onto an independent courier. The courier then performed a series of activities to simulate waiting in an airport. The second scenario tracked the activities of a manufacturer who also served as the courier. A sample set for each test consisted of thirty samples from various locations on each IED manufacturer, thirty from each IED courier, twenty-five from the manufacturing area, and twenty-five from the courier area. pre-samples and post-samples were collected for analysis with each detection technique. Samples analyzed by gc/chemiluminescence were taken by swiping a teflon coated sampling swipe across the surface of the sampling area to pick up any explosive particles. Samples analyzed by ion mobility spectrometry (IMS) were taken from the clothing of the manufacturer and courier by vacuuming the surface and collecting particulates on a fiberglass filter. Samples for IMS analysis from the manufacturing and courier rooms were taken by wiping a cotton sampling swipe across the surface of area. Currently, building IEDs and monitoring the explosive contamination is being directed towards detection with portal monitors.
引用
收藏
页码:335 / 341
页数:7
相关论文
共 50 条
  • [21] Data interpretation in GC-ion mobility spectrometry: Pecunia non Olet?
    Vautz, Wolfgang
    Liedtke, Sascha
    Martin, Bernd
    Drees, Carolin
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2018, 21 (03) : 97 - 103
  • [22] Characterizing the gas phase ion chemistry of an ion trap mobility spectrometry based explosive trace detector using a tandem mass spectrometer
    Kozole, Joseph
    Tomlinson-Phillips, Jill
    Stairs, Jason R.
    Harper, Jason D.
    Lukow, Stefan R.
    Lareau, Richard T.
    Boudries, Hacene
    Lai, Hanh
    Brauer, Carolyn S.
    TALANTA, 2012, 99 : 799 - 810
  • [23] Detection of explosive vapors by field asymmetric ion mobility spectrometry method with laser ionization
    Akmalov, Artem E.
    Chistyakov, Alexander A.
    Kotkovskii, Gennadii E.
    Kostarev, Vitalii A.
    COUNTERTERRORISM, CRIME FIGHTING, FORENSICS, AND SURVEILLANCE TECHNOLOGIES III, 2019, 11166
  • [24] ANYL 376-Separation and characterization of explosive compounds using high-field asymmetric waveform ion mobility spectrometry/mass spectrometry
    Wu, Ching-Hong Alex
    Yost, Richard A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2008, 236
  • [25] Wood preservatives on waste wood: Fast detection with GC/MS, GC/ECD and ion mobility spectrometry (IMS)
    Schroder, W
    Matz, G
    FIELD SCREENING EUROPE, 1997, : 347 - 350
  • [26] A new ppb-gas analyzer by means of GC-ion mobility spectrometry (GC-IMS)
    J. W. Leonhardt
    Journal of Radioanalytical and Nuclear Chemistry, 2003, 257 : 133 - 139
  • [27] A new ppb-gas analyzer by means of GC-ion mobility spectrometry (GC-IMS)
    Leonhardt, JW
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 257 (01) : 133 - 139
  • [28] Hydrocarbon detection using laser ion mobility spectrometry
    Oberhuettinger, C.
    Langmeier, A.
    Oberpriller, H.
    Kessler, M.
    Goebel, J.
    Mueller, G.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2009, 12 (01) : 23 - 32
  • [29] Using ion mobility spectrometry for screening the autoxidation of peanuts
    Tzschoppe, Manon
    Haase, Helen
    Hoehnisch, Michaela
    Jaros, Doris
    Rohm, Harald
    FOOD CONTROL, 2016, 64 : 17 - 21
  • [30] On-site analysis using ion mobility spectrometry
    Stach, J
    Flachowsky, J
    Schelhorn, H
    Brodacki, M
    FIELD SCREENING EUROPE, 1997, : 359 - 362