Percutaneous CT-Guided Biopsy of the Craniovertebral Junction: Safety, Diagnostic Yield, and Technical Notes

被引:5
|
作者
Spinnato, Paolo [1 ]
Rimondi, Eugenio [1 ]
Facchini, Giancarlo [1 ]
机构
[1] IRCCS Ist Ortoped Rizzoli, Diagnost & Intervent Radiol, I-40136 Bologna, Italy
关键词
bone neoplasms; image-guided biopsy; atlanto-axial joint; atlanto-occipital joint; SPINE; MANAGEMENT; ACCURACY; TUMOR;
D O I
10.3390/diagnostics12010168
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The craniovertebral junction defined as the occiput, the atlas, and the axis is a complex bony region that contains vital neural and vascular structures. We report the experience of a single academic institution regarding CT-guided biopsy of this skeletal region. We reviewed all of the CT-guided biopsies performed in our department, completed in the craniovertebral junction. We collected data in regard to biopsy procedures, patients' vital statistics, and histopathological diagnosis. In total, 16 patients (8M and 8F; mean age 52; range 16-86 years old) were included in this series. In eight patients, the lesions were located in the atlas vertebra (8/16-50%), in six patients in the axis (37.5%), and in two patients in the occiput (12.5%). No complications were observed during or after the procedures. All of the procedures were technically successful. The biopsy was diagnostic in 13/16 patients (81.3%): four metastatic lesions (25%-three breast and one prostate cancers), four multiple myeloma bone lesions (25%), three aneurismal bone cysts (18.8%), one aggressive hemangioma (6.3%), and one pseudogout (6.3%). Moreover, in two-thirds (66.6%) of non-diagnostic histological reports, malignancies were excluded. CT-guided percutaneous biopsy is a safe tool and allows obtaining a histological diagnosis, in most cases, even in the most delicate site of the human skeleton-the craniovertebral junction.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Diagnostic yield and complication rates of percutaneous transthoracic CT-guided coaxial needle biopsy in persistent pulmonary consolidation
    Wang, Juan
    Zhang, Tongyin
    Li, Haoyu
    Hu, Yuwan
    Xu, Yanyan
    Huang, Zhenguo
    Xie, Sheng
    Yang, Meng
    Sun, Hongliang
    JAPANESE JOURNAL OF RADIOLOGY, 2024, 42 (11) : 1305 - 1314
  • [32] Diagnostic accuracy of CT-guided percutaneous cutting needle biopsy for thymic tumours
    Yonemori, K.
    Tsuta, K.
    Tateishi, U.
    Uno, H.
    Asamura, H.
    Matsuno, Y.
    Kusumoto, M.
    CLINICAL RADIOLOGY, 2006, 61 (09) : 771 - 775
  • [33] Technical note:: CT-guided biopsy:: A new diagnostic method for paleopathological research
    Rühli, FJ
    Hodler, J
    Böni, T
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2002, 117 (03) : 272 - 275
  • [34] Safety and accuracy of aortic and periaortic CT-guided percutaneous core needle biopsy
    Pitot, Marika A.
    Gu, Chris N.
    Adamo, Daniel A.
    Kurup, Anil Nicholas
    Schmitz, John J.
    Packard, Annie T.
    ABDOMINAL RADIOLOGY, 2023, 48 (06) : 2148 - 2156
  • [35] Safety and accuracy of aortic and periaortic CT-guided percutaneous core needle biopsy
    Marika A. Pitot
    Chris N. Gu
    Daniel A. Adamo
    Anil Nicholas Kurup
    John J. Schmitz
    Annie T. Packard
    Abdominal Radiology, 2023, 48 : 2148 - 2156
  • [36] CT-guided lung biopsy: Factors influencing diagnostic yield and complication rate
    Anderson, JM
    Murchison, J
    Patel, D
    CLINICAL RADIOLOGY, 2003, 58 (10) : 791 - 797
  • [37] Best Practices: CT-Guided Percutaneous Sampling of Vertebral Discitis-Osteomyelitis and Technical Factors Maximizing Biopsy Yield
    Husseini, Jad S.
    Habibollahi, Sina
    Nelson, Sandra B.
    Rosenthal, Daniel, I
    Chang, Connie Y.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (05) : 1057 - 1068
  • [38] Safety profile and technical success of narrow window CT-guided percutaneous biopsy with blunt needle approach in the abdomen and pelvis
    Francesca Rigiroli
    Andrés Camacho
    Andrew Chung
    Syed Yasir Andrabi
    Alexander Brook
    Bettina Siewert
    Muneeb Ahmed
    Olga R. Brook
    European Radiology, 2024, 34 : 2364 - 2373
  • [39] Safety profile and technical success of narrow window CT-guided percutaneous biopsy with blunt needle approach in the abdomen and pelvis
    Rigiroli, Francesca
    Camacho, Andres
    Chung, Andrew
    Andrabi, Syed Yasir
    Brook, Alexander
    Siewert, Bettina
    Ahmed, Muneeb
    Brook, Olga R.
    EUROPEAN RADIOLOGY, 2024, 34 (04) : 2364 - 2373
  • [40] CT-guided percutaneous transthoracic needle biopsy for paramediastinal and nonparamediastinal lung lesions Diagnostic yield and complications in 1484 patients
    Wang, Ye
    Jiang, Faming
    Tan, Xiaobo
    Tian, Panwen
    MEDICINE, 2016, 95 (31)