Ablation of nonsustained or hemodynamically unstable ventricular arrhythmia originating from the right ventricular outflow tract guided by noncontact mapping

被引:19
|
作者
Fung, JWH [1 ]
Chan, HCK [1 ]
Chan, JYS [1 ]
Chan, WWL [1 ]
Kum, LCC [1 ]
Sanderson, JE [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Med & Therapeut, Div Cardiol, Hong Kong, Hong Kong, Peoples R China
来源
关键词
noncontact mapping; right ventricular outflow tract;
D O I
10.1046/j.1460-9592.2003.t01-1-00255.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Conventional activation or pacemapping is effective in guiding ablation of ventricular tachyarrhythmia originating from right ventricular outflow tract (RVOT). However, in selected patients with hemodynamically unstable or nonsustained tachycardia, noncontact mapping may be an effective alternative method to guide ablation in RVOT Five patients with symptomatic hypotension during ventricular tachycardia (VT) or nonsustained tachyarrhythmia originating from the RVOT had radiofrequency ablation guided by noncontact mapping. All patients had a history of syncope and the tachyarrhythmias were refractory to antiarrhythmic therapy. Four patients had spontaneous sustained VT of a cycle length from 250 to 300 ms and one had symptomatic ventricular ectopic beats. Two patients were diagnosed to have arrhythmogenic right ventricular cardiomyopathy (ARVC). Sustained VT with hypotension was induced in two patients and nonsustained VT in three patients. Isopotential color maps were used to locate the earliest activation site of the tachyarrhythmia in RVOT Three patients had tachyarrhythmia exit sites at the septal region and two at lateral region of RVOT Low voltage area and diastolic activity were detected in the two patients with ARVC. Radiofrequency ablation guided by noncontact mapping was performed during sinus rhythm in all patients. The number of ablation attempts ranged from 1 to 14. After follow-up for 12 +/- 5.8 months, there was no recurrence of tachyarrhythmia and syncope in all five patients. Noncontact mapping is a safe and effective alternative method to guide ablation of hemodynamically unstable or nonsustained ventricular arrhythmia originating from RVOT.
引用
收藏
页码:1699 / 1705
页数:7
相关论文
共 50 条
  • [41] INFLAMMATORY PSEUDOTUMOR ORIGINATING FROM THE RIGHT VENTRICULAR OUTFLOW TRACT
    Singh, Mohita
    Tabbaa, Rashed
    Khalid, Mirza Umair
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1196 - 1196
  • [42] Inflammatory Pseudotumor Originating from the Right Ventricular Outflow Tract
    Singh, Mohita
    Khalid, Umair
    Lakkis, Nasser
    Tabbaa, Rashed
    CASE REPORTS IN CARDIOLOGY, 2016, 2016
  • [43] NONSUSTAINED RIGHT VENTRICULAR OUTFLOW TRACT TACHYCARDIA - IMPLICATIONS AND MECHANISM
    KERR, CR
    RITCHIE, AH
    QI, A
    YEUNG, J
    CLINICAL RESEARCH, 1987, 35 (03): : A291 - A291
  • [44] This was ... outflow tract ventricular arrhythmia non-contact balloon guided ablation
    Primo, Joao
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2022, 41 (06) : 495 - 497
  • [45] Long term outcomes of right ventricular outflow tract ventricular arrhythmias ablation guided by non-contact mapping
    Zhang, Fengxiang
    Yang, Bing
    Chen, Hongwu
    Ju, Weizhu
    Cao, Kejiang
    Chen, Minglong
    CARDIOLOGY, 2013, 126 : 93 - 93
  • [46] LONG TERM OUTCOMES OF RIGHT VENTRICULAR OUTFLOW TRACT VENTRICULAR ARRHYTHMIAS ABLATION GUIDED BY NON-CONTACT MAPPING
    Zhang Fengxiang
    Zhang, Fengxiang
    Chen, Minglong
    HEART, 2013, 99 : E197 - E197
  • [47] Circadian variation of idiopathic ventricular tachycardia originating from right ventricular outflow tract
    Hayashi, H
    Fujiki, A
    Tani, M
    Usui, M
    Mizumaki, K
    Shimono, M
    Nagasawa, H
    Inoue, H
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (01): : 99 - +
  • [48] Pilsicainide-induced ventricular tachycardia originating from right ventricular outflow tract
    Shinohara, Tetsuji
    Takahashi, Naohiko
    Saikawa, Tetsunori
    Yoshimatsu, Hironobu
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (05) : 552 - 552
  • [49] Repetitive ventricular responses induced by radiofrequency ablation for idiopathic ventricular tachycardia originating from the outflow tract of the right ventricle
    Chinushi, M
    Aizawa, Y
    Ohhira, K
    Fujita, S
    Shiba, M
    Niwano, S
    Furushima, H
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (04): : 669 - 678
  • [50] MAGNETIC NAVIGATION FOR MAPPING AND ABLATION OF RIGHT VENTRICULAR OUTFLOW TRACT TACHYCARDIAS
    Parreira, L.
    Carmo, P.
    Cavaco, D.
    Reis-Santos, K.
    Cabrita, D.
    Marcelino, S.
    Adragao, P.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S14 - S14