Effect of Fabric Deformation on Thermal Protective Performance of Clothing in a Cylindrical Configuration

被引:1
|
作者
Su, Yun [1 ,2 ]
Li, Rui [3 ]
Yang, Jie [4 ]
Song, Guowen [3 ]
Xiang, Chunhui [3 ]
Li, Jun [1 ,2 ]
机构
[1] Donghua Univ, Coll Fash & Design, 1882,West Yan An Rd, Shanghai 200051, Peoples R China
[2] Donghua Univ, Key Lab Clothing Design & Technol, Minist Educ, 1882 West Yan An Rd, Shanghai 200051, Peoples R China
[3] Iowa State Univ, 515 Morrill Rd, Ames, IA 50010 USA
[4] Xian Univ Sci & Technol, Coll Safety Sci & Engn, 58 Yan Ta Middle Rd, Xian 710054, Shaanxi, Peoples R China
关键词
fabric deformation; thermal protective performance; clothing; body movement; stretching force; HEAT-TRANSFER; FIREFIGHTERS; ENERGY; MOTION; SKIN;
D O I
10.1520/STP161420180059
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Firefighting protective clothing is designed to provide thermal protection for firefighters in fire extinguishing or rescuing operations. However, fabric deformation and stretching due to body movement and different postures could change the clothing's thermal protective performance. Current gaps in our knowledge with regard to fabric deformation often resulted in biased predictions of the thermal protective level that personal protective equipment (PPE) can provide, highlighting the need to improve our understanding in this field. In this study, we developed a device that can be connected to a cylindrical copper calorimeter to simulate fabric deformation due to body movement and different postures and simultaneously measure the fabric's thermal properties. Stretching forces of varying magnitudes (of 0, 1.2, 2.1, and 3.1 psi) were applied to study the effect of fabric deformation on the thermal protective performance of clothing under low- and high-intensity heat exposures. In addition, we analyzed skin burn times with different stretching forces and fabric properties. The selected fabrics were stretched by approximately 15 % under a stretching force of 3.1 psi. Fabric deformation led to a significant reduction of the predicted thermal protective performance of fabrics, mainly due to changes in fabric thickness, porosity, and mass per unit area. Predicted skin burn times decreased for increasing stretching forces, although the decrease was less pronounced under high-intensity heat exposure as a result of fabric shrinkage and degradation. The findings from this study further advance our current understanding of the thermal protective performance of clothing and may lead to the development of a new test to characterize clothing performance under more realistic usage situations.
引用
收藏
页码:271 / 285
页数:15
相关论文
共 50 条
  • [21] Effect of air gaps characteristics on thermal protective performance of firefighters' clothing A review
    Deng, Meng
    Wang, Yunyi
    Li, Peijing
    INTERNATIONAL JOURNAL OF CLOTHING SCIENCE AND TECHNOLOGY, 2018, 30 (02) : 246 - 267
  • [22] Study of the Effect of Material Assembly on the Moisture and Thermal Protective Performance of Firefighter Clothing
    Cui, Zhiying
    Zhang, Weiyuan
    FIBRES & TEXTILES IN EASTERN EUROPE, 2009, 17 (06) : 80 - 83
  • [23] An Empirical Analysis of Thermal Protective Performance of Fabrics Used in Protective Clothing
    Mandal, Sumit
    Song, Guowen
    ANNALS OF OCCUPATIONAL HYGIENE, 2014, 58 (08): : 1065 - 1077
  • [24] Thermal Protective Performance of Aerogel Embedded Firefighter's Protective Clothing
    Qi, Zhengkun
    Huang, Dongmei
    He, Song
    Yang, Hui
    Hu, Yin
    Li, Liming
    Zhang, Heping
    JOURNAL OF ENGINEERED FIBERS AND FABRICS, 2013, 8 (02): : 134 - 139
  • [25] Thermal protective performance of firefighters' protective clothing in radiant heat exposures
    Dongmei, H. (dmhuang@cjlu.edu.cn), 1600, Baywood Publishing Co. Inc. (22):
  • [26] Research on Thermal Protective Performance of Thermal Insulation and Flame-retardant Protective Clothing
    Li, Fei-fei
    Zheng, Chun-qin
    Qin, Guan-mei
    Zhou, Xiao-hong
    SILK, PROTECTIVE CLOTHING AND ECO-TEXTILES, 2013, 796 : 607 - +
  • [27] Thermal protective performance of clothing exposed to radiant heat
    Kothari, V. K.
    Chakraborty, Supriyo
    JOURNAL OF THE TEXTILE INSTITUTE, 2015, 106 (12) : 1388 - 1393
  • [28] The Thermal Protective Performance of Firefighters' Clothing: The Air Gap Between the Clothing and the Body
    Ghazy, Ahmed
    HEAT TRANSFER ENGINEERING, 2017, 38 (10) : 975 - 986
  • [29] Effect of moisture and water on thermal protective performance of multilayered fabric assemblies for firefighters
    Chakraborty, Supriyo
    Kothari, V. K.
    INDIAN JOURNAL OF FIBRE & TEXTILE RESEARCH, 2017, 42 (01) : 94 - 99
  • [30] Performance analysis of shell fabric of fire protective clothing for different process parameters
    Rathour, Rochak
    Rajput, Bhavna
    Das, Apurba
    Alagirusamy, Ramasamy
    JOURNAL OF THE TEXTILE INSTITUTE, 2023, 114 (11) : 1682 - 1691