The 2-year follow-up results of a patient-specific interpositional knee implant

被引:0
|
作者
Koeck, F. X. [1 ]
Beckmann, J. [1 ]
Lechler, P. [1 ]
Goetz, J. [1 ]
Schaumburger, J. [1 ]
Grifka, J. [1 ]
机构
[1] Univ Regensburg, Asklepios Klinikum Bad Abbach, Klin & Poliklin Orthopadie, D-93077 Bad Abbach, Germany
来源
ORTHOPADE | 2011年 / 40卷 / 12期
关键词
Unicompartmental knee arthritis; Hemiarthroplasty; Interpositional implant; Implant dislocation; Patient-specific; MCKEEVER METALLIC HEMIARTHROPLASTY; ARTHROPLASTY; REPLACEMENT; UNISPACER; ARTHRITIS; WOMAC; OSTEOARTHRITIS; VALIDATION; REVISION; OUTCOMES;
D O I
10.1007/s00132-011-1790-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Besides the primary goal of functional improvement and pain reduction, the operative treatment of unicompartmental arthritis in younger patients is focused on preservation of intact bone and joint structures. The question arises whether an interpositional knee implant based on magnetic resonance imaging (MRI) data can be an alternative treatment option to the established procedures of high tibial osteotomy and unicompartmental knee arthroplasty. From June 2004 to May 2008 a total of 33 patients suffering from unicompartmental knee arthritis received a patient-specific interpositional implant (31 medial and 2 lateral) within a single arm trial. The mean follow-up time was 26.6 months (range 1-48 months) and the mean age of the patients was 54.5 years (range 39-65 years). In addition to the clinical results the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC) function scale and the Knee Society scores were measured. A descriptive data analysis, a variance analysis for repeated measurements and a determination of significance level were carried out. The 2-4 year results showed a significant improvement in the WOMAC function scale as well as the Knee Society scores. The knee function after 2 years was comparable to the preoperative situation with an extension to flexion of 0/2/130A degrees. The dislocation rate was 6% and the overall revision rate 21%. Despite acceptable functional results a significant pain relief, a complete preservation of bone and a lower rate of dislocations compared to the off-the-shelf Unispacer implant there were only limited indications for the customized interpositional knee implant with respect to the given contraindications due to the high 2 year revision rate.
引用
收藏
页码:1103 / +
页数:7
相关论文
共 50 条
  • [21] THE SCHACHAR LENS - A 2-YEAR FOLLOW-UP
    SCHACHAR, RA
    SCHACHAR, L
    OPHTHALMOLOGY, 1979, 86 (09) : 1631 - 1635
  • [22] Allogeneic parathyroid: 2-year follow-up
    Manuel Hermosillo-Sandoval, Jose
    Lisseth Leonher-Ruezga, Karla
    Alfredo Jimenez-Gomez, Jose
    Fuentes-Orozco, Clotilde
    Gonzalez-Ojeda, Alejandro
    Ricardo Ramirez-Gonzalez, Luis
    CIRUGIA Y CIRUJANOS, 2015, 83 (03): : 188 - 192
  • [23] SMR - 2-YEAR FOLLOW-UP SURVEY
    THOMAS, JN
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1978, 92 (08): : 661 - 666
  • [24] 2-YEAR FOLLOW-UP OF BIPOLAR HEMIARTHROPLASTY
    ROGALSKI, R
    HUEBNER, J
    GOULET, J
    KAUFER, H
    ORTHOPEDICS, 1993, 16 (07) : 759 - 765
  • [25] BRIEF HOSPITALIZATION - 2-YEAR FOLLOW-UP
    HERZ, MI
    ENDICOTT, J
    SPITZER, RL
    AMERICAN JOURNAL OF PSYCHIATRY, 1977, 134 (05): : 502 - 507
  • [26] 2-YEAR FOLLOW-UP OF HYPERACTIVE PRESCHOOLERS
    CAMPBELL, SB
    SCHLEIFER, M
    WEISS, G
    PERLMAN, T
    AMERICAN JOURNAL OF ORTHOPSYCHIATRY, 1977, 47 (01) : 149 - 162
  • [27] BRIEF HOSPITALIZATION - 2-YEAR FOLLOW-UP
    HERZ, MI
    ENDICOTT, J
    GIBBON, M
    ARCHIVES OF GENERAL PSYCHIATRY, 1979, 36 (06) : 701 - 705
  • [28] REHABILITATION OF IMPAIRED PHYSICIANS - 1-YEAR FOLLOW-UP AND 2-YEAR FOLLOW-UP
    HERRINGTON, RE
    BENZER, DG
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 1981, 5 (01) : 153 - 153
  • [29] A 2-Year Follow-up Study of an Absorbable Implant to Treat Nasal Valve Collapse
    San Nicolo, Marion
    Stelter, Klaus
    Sadick, Haneen
    Bas, Murat
    Berghaus, Alexander
    FACIAL PLASTIC SURGERY, 2018, 34 (05) : 545 - 550
  • [30] Early results with a patient specific interpositional knee device
    Brooks, Francis
    Akram, Tahira
    Roy, Stuart
    Pemberton, David
    Chandatreya, Amit
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (04): : 500 - 505