Fast T2 mapping using multi-echo spin-echo MRI: A linear order approach

被引:14
|
作者
Fatemi, Yaghoub [1 ]
Danyali, Habibollah [1 ]
Helfroush, Mohammad Sadegh [1 ]
Amiri, Houshang [2 ,3 ]
机构
[1] Shiraz Univ Technol, Dept Elect & Elect Engn, Shiraz, Iran
[2] Kerman Univ Med Sci, Neurosci Res Ctr, Inst Neuropharmacol, Kerman, Iran
[3] Vrije Univ Amsterdam Med Ctr, Dept Radiol & Nucl Med, De Boelelaan 1117, NL-1007 MB Amsterdam, Noord Holland, Netherlands
关键词
extended phase graph; indirect echoes; magnetic resonance imaging; stimulated echoes; T-2 relaxation time; TRANSVERSE RELAXOMETRY; MAGNETIZATION-TRANSFER; RELAXATION; SEQUENCES; PHASE; QUANTIFICATION; PATHOLOGY; DESIGN; SIGNAL; TRAINS;
D O I
10.1002/mrm.28309
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Multi-echo spin-echo sequence is commonly used for T-2 mapping. The estimated values using conventional exponential fit, however, are hampered by stimulated and indirect echoes leading to overestimation of T-2. Here, we present fast analysis of multi-echo spin-echo (FAMESE) as a novel approach to decrease the complexity of the search space, which leads to accelerated measurement of T-2. Methods We developed FAMESE based on mathematical analysis of the Bloch equations in which the search space dimension decreased to only one. Then, we tested it in both phantom and human brain. Bland-Altman plot was used to assess the agreement between the estimated T-2 values from FAMESE and the ones estimated from single-echo spin-echo sequence. The reliability of FAMESE was assessed by intraclass correlation coefficients. In addition, we investigated the noise stability of the method in synthetic and experimental data. Results In both phantom and healthy participants, FAMESE provided accelerated and SNR-resistant T-2 maps. The FAMESE had a very good agreement with the single-echo spin echo for the whole range of T-2 values. The intraclass correlation coefficient values for FAMESE were excellent (ie, 0.9998 and 0.9860 < intraclass correlation coefficient < 0.9942 for the phantom and humans, respectively). Conclusion Our developed method FAMESE could be considered as a candidate for rapid T-2 mapping with a clinically feasible scan time.
引用
收藏
页码:2815 / 2830
页数:16
相关论文
共 50 条
  • [41] Simple recipe for accurate T2 quantification with multi spin-echo acquisitions
    Daniel Neumann
    Martin Blaimer
    Peter M. Jakob
    Felix A. Breuer
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 567 - 577
  • [42] Dual-pathway multi-echo sequence for simultaneous frequency and T2 mapping
    Cheng, Cheng-Chieh
    Mei, Chang-Sheng
    Duryea, Jeffrey
    Chung, Hsiao-Wen
    Chao, Tzu-Cheng
    Panych, Lawrence P.
    Madore, Bruno
    JOURNAL OF MAGNETIC RESONANCE, 2016, 265 : 177 - 187
  • [43] T2-weighted MRI of rectosigmoid carcinoma: Comparison of respiratory-triggered fast spin-echo, breathhold fast-recovery fast spin-echo, and breathhold single-shot fast spin-echo sequences
    Yamashita, Shuhei
    Masui, Takayuki
    Katayama, Motoyuki
    Sato, Kimihiko
    Yoshizawa, Nobuko
    Seo, Hidekazu
    Sakahara, Harumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 511 - 516
  • [44] Gradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping
    Sprinkart, Alois M.
    Luetkens, Julian A.
    Traeber, Frank
    Doerner, Jonas
    Gieseke, Juergen
    Schnackenburg, Bernhard
    Schmitz, Georg
    Thomas, Daniel
    Homsi, Rami
    Block, Wolfgang
    Schild, Hans
    Naehle, Claas P.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [45] Gradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping
    Alois M Sprinkart
    Julian A Luetkens
    Frank Träber
    Jonas Doerner
    Jürgen Gieseke
    Bernhard Schnackenburg
    Georg Schmitz
    Daniel Thomas
    Rami Homsi
    Wolfgang Block
    Hans Schild
    Claas P Naehle
    Journal of Cardiovascular Magnetic Resonance, 17
  • [46] T2*quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients
    Shin, Seonyeong
    Yun, Seong Dae
    Shah, N. Jon
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [47] MRI of the intracerebral lesions at 0.5 tesla: Comparison of fast spin-echo and conventional spin-echo sequences
    Incesu, L
    Gunes, M
    Akan, H
    Selcuk, MB
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1996, 20 (02) : 105 - 113
  • [48] Comparison of lumbar degenerative disc disease using conventional fast spin echo T2W MRI and T2 fast spin echo dixon sequences
    Saifuddin, Asif
    Rajakulasingam, Ramanan
    Santiago, Rodney
    Siddiqui, Mateen
    Khoo, Michael
    Pressney, Ian
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1121):
  • [49] T2* quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients
    Seonyeong Shin
    Seong Dae Yun
    N. Jon Shah
    Scientific Reports, 13
  • [50] MINIMIZING ERRORS IN T2 DETERMINATIONS WITH SPIN-ECHO EQUIPMENT
    MEHLKOPF, AF
    SMIDT, J
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (04): : 253 - &