Radiometric calibration of frame transfer CCD camera with uniform source system

被引:0
|
作者
Zhou Jiankang [1 ,2 ]
Shi Rongbao [1 ,2 ]
Chen Yuheng [1 ,2 ]
Zhou Yuying [1 ,2 ]
Shen Weimin [1 ,2 ]
机构
[1] Soochow Univ, Inst Modern Opt Technol, Suzhou 215006, Peoples R China
[2] Jiangsu Key Lab Modern Opt Technol, Suzhou 215006, Peoples R China
关键词
radiometric calibration; visibility function; integrating sphere; shift smear; frame transfer CCD;
D O I
10.1117/12.885418
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents a radiometric calibration method based on visibility function and uniform source system. The uniform system is mainly comprised of an integrating sphere and a monitoring silicon detector. The current of the silicon detector with a visibility function filter corresponds to the luminance at the exit port of integrating sphere through standard luminance meter transfer. The radiance at the camera entrance pupil is calculated for different solar zenith angles and Earth surface albedos by the MODTRAN atmospheric code. To simplify the calibration process, the radiance at its entrance pupil is integrated by visibility function. The shift smear of the frame transfer CCD is removed by the radiometric calibration and the amending ratio factor is introduced in the retrieving methods. The imaging experiment verifies the reliability of the calibration method and retrieves good quality image.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Radiometric Calibration Chain Design Based on Uniform Collimated Laser Source
    Liwei Sun
    Xin Ye
    Wei Fang
    Zhenlei He
    Yupeng Wang
    [J]. Journal of Beijing Institute of Technology, 2018, 27 (03) : 385 - 390
  • [22] Smear correction of frame transfer CCD camera based on the integrating sphere
    Feng, Weiwei
    Chen, Ligang
    [J]. OPTIK, 2013, 124 (14): : 1805 - 1807
  • [23] Evaluation Criteria and Correction Method of Frame Transfer CCD Camera Smearing
    Li Yang
    Luo Donggen
    Sun Liang
    Li Shuang
    Yao Pingping
    Xiang Guangfeng
    Fang Lulu
    Hong Jin
    [J]. ACTA PHOTONICA SINICA, 2022, 51 (04) : 135 - 149
  • [24] COLOR REPRODUCTION OF A SINGLE CHIP COLOR CAMERA WITH A FRAME TRANSFER CCD
    ISHIKAWA, K
    HASHIMOTO, S
    SONE, Y
    KUNII, T
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1981, 16 (02) : 101 - 103
  • [25] Radiometric calibration for InSb FPA camera
    Zahler, M
    [J]. INFRARED TECHNOLOGY AND APPLICATIONS XXIII, PTS 1 AND 2, 1997, 3061 : 850 - 857
  • [26] Radiometric calibration for InSb FPA camera
    Zahler, M
    [J]. 10TH MEETING ON OPTICAL ENGINEERING IN ISRAEL, 1997, 3110 : 649 - 656
  • [27] A radiometric calibration for the Clementine HIRES camera
    Robinson, MS
    Malaret, E
    White, T
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-PLANETS, 2003, 108 (E4)
  • [28] Radiometric Calibration of the Rosetta Navigation Camera
    Geiger, Bernhard
    Andres, Rafael
    Statella, Thiago
    [J]. JOURNAL OF ASTRONOMICAL INSTRUMENTATION, 2021, 10 (01)
  • [29] Vicarious Radiometric Calibration of a Multispectral Camera on Board an Unmanned Aerial System
    Del Pozo, Susana
    Rodriguez-Gonzalvez, Pablo
    Hernandez-Lopez, David
    Felipe-Garcia, Beatriz
    [J]. REMOTE SENSING, 2014, 6 (03) : 1918 - 1937
  • [30] Radiometric calibration of wide-field camera system with an application in astronomy
    Vitek, Stanislav
    Nasyrova, Maria
    Stehlikova, Veronika
    [J]. APPLICATIONS OF DIGITAL IMAGE PROCESSING XL, 2017, 10396