Fluoride production in CMS Resistive Plate Chambers and aging study

被引:0
|
作者
Gelmi, A. [1 ,2 ]
Miguel, O. [3 ]
Kumari, P. [4 ]
Guida, R. [5 ]
Mandelli, B. [5 ]
机构
[1] Univ Bari, Bari, Italy
[2] INFN Bari, Bari, Italy
[3] Univ Iberoamer, Mexico City, DF, Mexico
[4] Panjab Univ, Chandigarh, India
[5] CERN, EP DT, Meyrin, Switzerland
关键词
HF PRODUCTION;
D O I
暂无
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The CMS resistive plate chambers (RPC) detectors operate with a gas mixture based on HydroFluoroCarbon components. The pollutants produced in the gas under high electrical discharge and radiation may accelerate the detectors aging, in particular the fluorine ions (F-) produced as part of the compound hydrogen fluoride (HF) may damage the inner detector surface due to its high chemical reactivity. The HF production rate has been studied at CERN Gamma Irradiation Facility (GIF++) as a function of the background rate and the gas flow. Finally, the possible aging effects induced by the radiation in the CMS RPC system, including the HF effects, have been studied after almost seven years of operation.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Performance study of the CMS barrel resistive plate chambers with cosmic rays
    Chatrchyan, S.
    Khachatryan, V.
    Sirunyan, A. M.
    Adam, W.
    Arnold, B.
    Bergauer, H.
    Bergauer, T.
    Dragicevic, M.
    Eichberger, M.
    Eroe, J.
    Friedl, M.
    Fruehwirth, R.
    Ghete, V. M.
    Hammer, J.
    Haensel, S.
    Hoch, M.
    Hoermann, N.
    Hrubec, J.
    Jeitler, M.
    Kasieczka, G.
    Kastner, K.
    Krammer, M.
    Liko, D.
    de Abril, I. Magrans
    Mikulec, I.
    Mittermayr, F.
    Neuherz, B.
    Oberegger, M.
    Padrta, M.
    Pernicka, M.
    Rohringer, H.
    Schmid, S.
    Schoefbeck, R.
    Schreiner, T.
    Stark, R.
    Steininger, H.
    Strauss, J.
    Taurok, A.
    Teischinger, F.
    Themel, T.
    Uhl, D.
    Wagner, P.
    Waltenberger, W.
    Walzel, G.
    Widl, E.
    Wulz, C. -E.
    Chekhovsky, V.
    Dvornikov, O.
    Emeliantchik, I.
    Litomin, A.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [12] Longevity study on the CMS resistive plate chambers for HL-LHC
    Aly, R.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (08):
  • [13] Performance of Resistive Plate Chambers for the muon detection at CMS
    Abbrescia, M
    Colaleo, A
    Iaselli, G
    Loddo, F
    Maggi, M
    Marangelli, B
    Natali, S
    Nuzzo, S
    Pugliese, G
    Ranieri, A
    Romano, F
    Altieri, S
    Bruno, G
    Gianini, G
    Ratti, SP
    Viola, L
    Vitulo, P
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 90 - 95
  • [14] Production and Performance of RE4 Resistive Plate Chambers for CMS experiment upgrade
    Jeong, Min Soo
    Lee, Kyong Sei
    Park, Sung Keun
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [15] Study of HF production in BaBar Resistive Plate Chambers
    Band, H. R.
    Bellini, F.
    Covarelli, R.
    Di Marco, E.
    D'Orazio, A.
    Ferroni, F.
    Gioi, L. Li
    Lopez, L.
    Polci, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (01): : 33 - 38
  • [16] On aging problem of glass Resistive Plate Chambers
    Bhide, S. S.
    Datar, V. M.
    Kalmani, S. D.
    Mondal, N. K.
    Pant, L. M.
    Satyanarayana, B.
    Shinde, R. R.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 158 : 195 - 198
  • [17] Assembly and Characterization of Resistive Plate Chambers in India for the CMS Detector
    Kumar, R.
    Mehta, A.
    Bhatnagar, V.
    Singh, J. B.
    Chudasama, R.
    Mohanty, A. K.
    Pant, L. M.
    Sehgal, R.
    Sehgal, S. T.
    Thomas, R. G.
    XXI DAE-BRNS HIGH ENERGY PHYSICS SYMPOSIUM, 2016, 174 : 553 - 557
  • [18] A prototype front end chip for the CMS resistive plate chambers
    Abbrescia, M
    Colaleo, A
    Guarrasi, L
    Iaselli, G
    Loddo, F
    Maggi, M
    Marangelli, B
    Natali, S
    Nuzzo, S
    Pugliese, G
    Ranieri, A
    Romano, F
    Altieri, S
    Belli, G
    Bruno, G
    Gianini, G
    Ratti, SP
    Riccardi, C
    Torre, P
    Viola, L
    Vitulo, P
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 457 - 461
  • [19] Resistive Plate Chambers performance with Cosmic Rays in the CMS experiment
    Piccolo, D.
    Darmenov, N.
    Genchev, V.
    Iaydjiev, P.
    Stoykova, S.
    Sultanov, G.
    Trayanov, R.
    Dimitrov, A.
    Litov, L.
    Pavlov, B.
    Petkov, P.
    Marinov, A.
    Thyssen, F.
    Tytgat, M.
    Verwilligen, P.
    Zaganidis, N.
    Akimenko, S.
    Ball, A.
    Crotty, I.
    Guida, R.
    Sharma, A.
    Van Doninck, W.
    Abbrescia, M.
    Iaselli, G.
    Marangelli, B.
    Nuzzo, S.
    Pugliese, G.
    Romano, F.
    Roselli, G.
    Trentadue, R.
    Tupputi, S.
    Colaleo, A.
    Loddo, F.
    Ranieri, A.
    Cimmino, A.
    Sciacca, C.
    Buontempo, S.
    Cavallo, N.
    Fabozzi, F.
    Lomidtze, D.
    Paolucci, P.
    Benussi, L.
    Bertani, M.
    Bianco, S.
    Colafranceschi, S.
    Fabbri, F. L.
    Baesso, P.
    Pagano, D.
    Ratti, S. P.
    Vitulo, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 180 - 182
  • [20] CMS Resistive Plate Chambers performance at √s=13 TeV
    Cabrera-Mora, Andres L.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,