Application of Computer Analysis of Mammography Phantom Images (CAMPI) methodology to the comparison of two digital biopsy machines

被引:4
|
作者
Chakraborty, DP [1 ]
Fatouros, PP [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
PHYSICS OF MEDICAL IMAGING | 1998年 / 3336卷
关键词
stereotactic; biopsy; digital; mammography; phantom; analysis; MQSA; ACR;
D O I
10.1117/12.317066
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this research was to compare a Fischer MammoVision/MammoTest and a LoRad DSM digital biopsy machine using the Computer Analysis of Mammography Phantom Images (CAMPI) methodology. This study reports on analysis of the 4 largest microcalcification groups (M1, M2, M3 and M4) and the largest nodule (N1) in a mammography accreditation phantom on images acquired at 26 kVp and different mAs values on the two machines. Both machines were linear in response but the MammoTest was more sensitive (i.e., it yielded a larger gray-scale value for a given x-ray technique). However, even after correcting for this difference, the CAMPI noise measure was substantially smaller for the LoRad than the MammoTest over the range of mAs values studied. Similarly, the CAMPI signal-to-noise-ratio and correlation measures were higher for the LoRad than the MammoTest over the same range of mAs, especially for the larger objects (M1/M2 and N1). For the smaller specks in M3/M4 somewhat closer performance was observed. The overall differences are attributed to better contrast/noise performance of the LoRad which appear to outweigh its lesser resolution capability. Our results are in agreement with earlier physical and psychophysical measurements using different methodologies. This work also describes better predictive models (i.e., fits) to describe the variation of all CAMPI measures with mAs at constant kVp. For example, the noise measure was fitted to a function that included physically reasonable sources of noise e.g., dark noise and detector gain fluctuations, in addition to the usual quantum noise. These fits can be used to summarize machine performance and to predict dependencies on other variables (e.g., exposure or dose) that are related to the mAs.
引用
收藏
页码:618 / 628
页数:11
相关论文
共 18 条
  • [1] Computer analysis of mammography phantom images (CAMPI)
    Chakraborty, DP
    [J]. PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 292 - 299
  • [2] Computer analysis of mammography phantom images (CAMPI): An application to the measurement of microcalcification image quality of directly acquired digital images
    Chakraborty, DP
    [J]. MEDICAL PHYSICS, 1997, 24 (08) : 1269 - 1277
  • [3] Comparison of computer analysis of mammography phantom images (CAMPI) with perceived image quality of phantom targets in the ACR phantom
    Chakraborty, DP
    [J]. IMAGE PERCEPTION: MEDICAL IMAGING 1997, 1997, 3036 : 160 - 167
  • [4] Automated analysis of phantom images for the evaluation of long-term reproducibility in digital mammography
    Gennaro, G.
    Ferro, F.
    Contento, G.
    Fornasin, F.
    di Maggio, C.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (05): : 1387 - 1407
  • [5] Design and application of a structured phantom for detection performance comparison between breast tomosynthesis and digital mammography
    Cockmartin, L.
    Marshall, N. W.
    Zhang, G.
    Lemmens, K.
    Shaheen, E.
    Van Ongeval, C.
    Fredenberg, E.
    Dance, D. R.
    Salvagnini, E.
    Michielsen, K.
    Bosmans, H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (03): : 758 - 780
  • [6] Comparative power law analysis of structured breast phantom and patient images in digital mammography and breast tomosynthesis
    Cockmartin, L.
    Bosmans, H.
    Marshall, N. W.
    [J]. MEDICAL PHYSICS, 2013, 40 (08)
  • [7] Comparison of conventional and secondarily digitized mammograms by ROC -: Analysis to evaluate a computer system for digital routine mammography
    Marx, C
    Fleck, M
    Böhm, T
    Gessner, C
    Hochmuth, A
    Kaiser, WA
    [J]. DIGITAL MAMMOGRAPHY, 1998, 13 : 495 - 496
  • [8] Comparison of conventional and secondarily digitized mammograms by ROC. Analysis to evaluate a computer system for digital routine mammography
    Marx, C
    Fleck, M
    Boehm, T
    Gessner, C
    Przetak, C
    Hochmuth, A
    Kaiser, WA
    [J]. 10TH INTERNATIONAL CONGRESS ON SENOLOGY - BREAST DISEASES OF THE SENOLOGIC INTERNATIONAL SOCIETY, 1998, : 515 - 518
  • [9] Comparison of conventional and secondarily digitized mammograms: ROC analysis of 200 cases to evaluate a computer system for digital routine mammography
    Marx, C
    Fleck, M
    Boehm, T
    Gessner, C
    Przetak, CG
    Kaiser, WA
    [J]. RADIOLOGY, 1998, 209P : 238 - 238
  • [10] EVALUATION AND ANALYSIS OF THE APPLICATION OF INTERACTIVE DIGITAL RESOURCES IN A BLENDED-LEARNING METHODOLOGY FOR A COMPUTER NETWORKS SUBJECT
    Candelas, Francisco A.
    Gil, Pablo
    Jara, Carlos A.
    Corrales, Juan A.
    [J]. 2011 4TH INTERNATIONAL CONFERENCE OF EDUCATION, RESEARCH AND INNOVATION (ICERI), 2011, : 6596 - 6605