Automated analysis of phantom images for the evaluation of long-term reproducibility in digital mammography

被引:8
|
作者
Gennaro, G.
Ferro, F.
Contento, G.
Fornasin, F.
di Maggio, C.
机构
[1] Univ Padua, Dept Oncol & Surg Sci, I-35128 Padua, Italy
[2] IOV, Padua, Italy
[3] Cyberqual Srl, Gorizia, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 05期
关键词
D O I
10.1088/0031-9155/52/5/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The performance of an automatic software package was evaluated with phantom images acquired by a full-field digital mammography unit. After the validation, the software was used, together with a Leeds TORMAS test object, to model the image acquisition process. Process modelling results were used to evaluate the sensitivity of the method in detecting changes of exposure parameters from routine image quality measurements in digital mammography, which is the ultimate purpose of long-term reproducibility tests. Image quality indices measured by the software included the mean pixel value and standard deviation of circular details and surrounding background, contrast-to-noise ratio and relative contrast; detail counts were also collected. The validation procedure demonstrated that the software localizes the phantom details correctly and the difference between automatic and manual measurements was within few grey levels. Quantitative analysis showed sufficient sensitivity to relate fluctuations in exposure parameters (kV(p) or mAs) to variations in image quality indices. In comparison, detail counts were found less sensitive in detecting image quality changes, even when limitations due to observer subjectivity were overcome by automatic analysis. In conclusion, long-term reproducibility tests provided by the Leeds TORMAS phantom with quantitative analysis of multiple IQ indices have been demonstrated to be effective in predicting causes of deviation from standard operating conditions and can be used to monitor stability in full-field digital mammography.
引用
收藏
页码:1387 / 1407
页数:21
相关论文
共 50 条
  • [1] A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme
    G. Gennaro
    A. Ballaminut
    G. Contento
    [J]. European Radiology, 2017, 27 : 3776 - 3787
  • [2] A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme
    Gennaro, G.
    Ballaminut, A.
    Contento, G.
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (09) : 3776 - 3787
  • [3] Reproducibility of automated volumetric breast density assessment in short-term digital mammography reimaging
    Ko, Eun Sook
    Kim, Rock Bum
    Han, Boo-Kyung
    [J]. CLINICAL IMAGING, 2015, 39 (04) : 582 - 586
  • [5] Automated scoring for CD-MAM phantom on digital mammography
    Muller, S
    Ciofolo, C
    Peter, G
    Noël, A
    Stinès, J
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 136 - 138
  • [6] Computer analysis of mammography phantom images (CAMPI)
    Chakraborty, DP
    [J]. PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 292 - 299
  • [7] Quantitative evaluation of phantom images for mammography quality control
    Imamura, K
    Fukuda, M
    Nakajima, Y
    Tukamoto, H
    Osanai, S
    Matumoto, T
    Higashida, Y
    Ishikawa, T
    [J]. CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 15 - 20
  • [8] Computerized analysis of mammographic phantom images: An image quality evaluation system for mammography
    Chakraborty, DP
    Zhao, XM
    Gingold, EL
    Sullivan, DC
    [J]. RADIOLOGY, 1996, 201 : 834 - 834
  • [9] Phantom evaluation of the role of the grid in digital spot mammography
    de Paredes, ESS
    Fatouros, FF
    Hogge, JP
    Wilson, JD
    Thunberg, SJ
    Cousins, J
    [J]. RADIOLOGY, 1998, 209P : 315 - 315
  • [10] Image quality assessment and equipment optimisation with automated phantom evaluation in full field digital mammography (FFDM)
    Oberholer, Nadia
    Paruccini, Nicoletta
    Moroder, Ehrenfried
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 235 - +