Intravoxel incoherent motion diffusion-weighted imaging for assessment of histologic grade of hepatocellular carcinoma: comparison of three methods for positioning region of interest

被引:38
|
作者
Wei, Yi [1 ]
Gao, Feifei [2 ]
Wang, Min [1 ]
Huang, Zixing [1 ]
Tang, Hehan [1 ]
Li, Jiaxing [3 ]
Wang, Yi [1 ]
Zhang, Tong [1 ]
Wei, Xiaocheng [4 ]
Zheng, Dandan [4 ]
Song, Bin [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Radiol, Chengdu 610041, Peoples R China
[2] Henan Prov Peoples Hosp, Dept Radiol, Zhengzhou, Henan, Peoples R China
[3] Sichuan Univ, West China Hosp, Dept Liver Surg, Chengdu, Sichuan, Peoples R China
[4] GE Healthcare China, Beijing, Peoples R China
关键词
Magnetic resonance imaging; Hepatocellular carcinoma; Diagnostic imaging; COEFFICIENT;
D O I
10.1007/s00330-018-5638-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo prospectively compare the diagnostic performances of three methods of region of interest (ROI) placement for the measurements of intravoxel incoherent motion (IVIM) diffusion-weighted MR imaging in differentiating the histologic grade of hepatocellular carcinoma (HCC).MethodsEighty-seven patients with 91 newly diagnosed HCCs were studied using IVIM imaging. Two attending radiologists separately identified the selection of tumour tissue for ROI positioning. Three different ROI positioning methods, namely the whole tumour volume (WTV) method, three-ROI method and one-section method, were used for the measurement. Kruskal-Wallis rank test or one-way ANOVA was used to compare the difference in IVIM parameters and ADC across the three different ROI positioning methods. Spearman correlation analysis was used to determine the correlation between each parameter and Edmondson-Steiner (E-S) grade. Receiver operating characteristics (ROC) curve analyses were performed to evaluate the diagnostic performance.ResultsFor the ADC and ADC(slow), the mean value measured by using the WTV method was significant higher than the one-section and three-ROI methods (all p < 0.01). For the ADC(slow), the highest area under curve (AUC) with a value of 0.969 was obtained by using the WTV method, followed by the one-section method (AUC = 0.938) and three-ROI method (AUC = 0.873). Additionally, for the ADC, AUC values were 0.861 for WTV method, 0.840 for one-section method and 0.806 for three-ROI method.ConclusionsDifferent ROI positioning methods used significantly affect the IVIM parameters and ADC measurements. Measurements of ADC(slow) value derived from WTV method entailed the highest diagnostic performance in grading HCC.
引用
收藏
页码:535 / 544
页数:10
相关论文
共 50 条
  • [41] Intravoxel incoherent motion diffusion-weighted imaging for discrimination of benign and malignant retropharyngeal nodes
    So, Tiffany Y.
    Ai, Qi-Yong H.
    Lam, W. K. Jacky
    Qamar, Sahrish
    Poon, Darren M. C.
    Hui, Edwin P.
    Mo, Frankie K. F.
    Chan, K. C. Allen
    King, Ann D.
    NEURORADIOLOGY, 2020, 62 (12) : 1667 - 1676
  • [42] Intravoxel incoherent motion diffusion-weighted imaging for monitoring chemotherapeutic efficacy in gastric cancer
    Xiao-Li Song
    Heoung Keun Kang
    Gwang Woo Jeong
    Kyu Youn Ahn
    Yong Yeon Jeong
    Yang Joon Kang
    Hye Jung Cho
    Chung Man Moon
    World Journal of Gastroenterology, 2016, (24) : 5520 - 5531
  • [43] Intravoxel incoherent motion diffusion-weighted imaging in stroke patients: initial clinical experience
    Yao, Y.
    Zhang, S.
    Tang, X.
    Zhang, S.
    Shi, J.
    Zhu, W.
    Zhu, W.
    CLINICAL RADIOLOGY, 2016, 71 (09) : 938.e11 - 938.e16
  • [44] Functional diagnosis of placenta accreta by intravoxel incoherent motion model diffusion-weighted imaging
    Yuwei Bao
    Ying Pang
    Ziyan Sun
    Qian Li
    Dazhong Tang
    Liming Xia
    European Radiology, 2021, 31 : 740 - 748
  • [45] Intravoxel incoherent motion diffusion-weighted imaging for evaluating the pancreatic perfusion in cirrhotic patients
    Ran Hu
    Guo-Fei Zeng
    Yu Fang
    Lisha Nie
    Hui-Lou Liang
    Zhi-Gang Wang
    Hua Yang
    Abdominal Radiology, 2024, 49 : 492 - 500
  • [46] Intravoxel incoherent motion diffusion-weighted imaging for discrimination of benign and malignant retropharyngeal nodes
    Tiffany Y. So
    Qi-Yong H. Ai
    W. K. Jacky Lam
    Sahrish Qamar
    Darren M. C. Poon
    Edwin P. Hui
    Frankie K. F. Mo
    K. C. Allen Chan
    Ann D. King
    Neuroradiology, 2020, 62 : 1667 - 1676
  • [47] The Application of Intravoxel Incoherent Motion Diffusion-Weighted Imaging in the Diagnosis of Hilar Obstructive Jaundice
    Xu, Xin
    Zhang, Xuening
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (02) : 228 - 234
  • [48] Intravoxel incoherent motion diffusion-weighted imaging for monitoring chemotherapeutic efficacy in gastric cancer
    Song, Xiao-Li
    Kang, Heoung Keun
    Jeong, Gwang Woo
    Ahn, Kyu Youn
    Jeong, Yong Yeon
    Kang, Yang Joon
    Cho, Hye Jung
    Moon, Chung Man
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (24) : 5520 - 5531
  • [49] Preliminary Application of Intravoxel Incoherent Motion Diffusion-Weighted Imaging in Diagnosing Lung Cancer
    Jin, Xianwen
    Liu, Xianling
    Hou, Yuejiao
    Song, Gesheng
    Zhang, Chengqi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (04) : 776 - 780
  • [50] Functional diagnosis of placenta accreta by intravoxel incoherent motion model diffusion-weighted imaging
    Bao, Yuwei
    Pang, Ying
    Sun, Ziyan
    Li, Qian
    Tang, Dazhong
    Xia, Liming
    EUROPEAN RADIOLOGY, 2021, 31 (02) : 740 - 748