A novel free-cooling scheme for combustion turbine inlet air cooling

被引:0
|
作者
Zamzann, Montaser M. [1 ]
Ai-Amiri, Abdalla M. [2 ]
机构
[1] Abu Dhabi Co Onshore Oil Operat ADCO, Abu Dhabi, U Arab Emirates
[2] United Arab Emirates Univ, Dept Mech Engn, Al Ain, U Arab Emirates
关键词
free cooling; cooling tower; combustion turbine inlet air cooling;
D O I
10.1115/1.2749287
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Free cooling is a well-known concept in the HVAC industry in which the cold water produced by a cooling tower is used directly to satisfy the requirement of the cooling load without assistance by the chiller; this concept, however is not reported in the turbine inlet air-cooling applications. Free cooling works well as long as the ambient wet bulb temperature (WBT) is sufficiently low to produce cold water at the required temperature, but once WBT reaches its threshold value (hence, free-cooling mode is ceased) and the chiller kicks off working under its normal mode of operation, i.e., free cooling is either enabled or disabled. The proposed system in this paper provides, in addition to the above modes of operation, a novel mode that utilizes the cooling tower as a primary source of cooling simultaneously with the chiller that serves as a secondary source at elevated WBT This new feature significantly reduces the yearly operating hours of the chiller and possibly its size, depending on the desired inlet air temperature, actual weather conditions, and design WBT Chiller size can vary between 0% and 100% as compared to a similar classical chiller system with significant reduction in the operating hours. The proposed system consists basically of chiller cooling tower, cooling coils, interconnecting piping, and controls. The arrangement of the system equipment changes with the operation modes in two configurations: dual water circulation loops and single water circulation loop. In the dual-loop configuration, the system has two separate loops such that the evaporator and the cooling coils are tied in one loop, while the cooling tower and condenser in the other loop; whereas in the single-loop configuration, all equipment is connected in series in one water circulation loop. This paper presents the major equipment and characteristics of the novel chiller scheme. In addition, the study outlines the potential reduction in the chiller load, size, and operating hours under a generalized weather envelope. The paper portrays the feasibility of using the proposed cooling scheme for turbine inlet air cooling.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] INFLUENCE OF ATMOSFERIC AIR CONDITIONS AND INLET AIR COOLING SYSTEMS ON GAS TURBINE PERFORMANCE
    Guirardi, W.
    Peixoto, R. A.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 4197 - 4205
  • [32] Improving Khangiran gas turbine efficiency by two standard and one novel inlet air cooling method
    Mahdi Deymi-Dashtebayaz
    Mahmood Farzaneh-Gord
    Ahmad Arabkoohsar
    Amir Bak Khoshnevis
    Hadi Akeififar
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2014, 36 : 571 - 582
  • [33] Improving Khangiran gas turbine efficiency by two standard and one novel inlet air cooling method
    Deymi-Dashtebayaz, Mahdi
    Farzaneh-Gord, Mahmood
    Arabkoohsar, Ahmad
    Khoshnevis, Amir Bak
    Akeififar, Hadi
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2014, 36 (03) : 571 - 582
  • [34] Analysis of Combined Effects of Air Transpiration Cooling and Evaporative Inlet Air Cooling on the Performance Parameters of a Simple Gas Turbine Cycle
    Mohapatra, Alok Ku
    Sanjay
    JOURNAL OF ENERGY ENGINEERING, 2015, 141 (03)
  • [35] A theoretical investigation on exergy analysis of a gas turbine cycle subjected to inlet air cooling and evaporative after cooling
    Khaliq, Abdul
    Haroon, Suleman
    Habib, M. A.
    INTERNATIONAL JOURNAL OF EXERGY, 2018, 27 (03) : 364 - 392
  • [36] GAS TURBINE PERFORMANCE ENHANCEMENT BY INLET AIR COOLING AND COOLANT PRE-COOLING USING AN ABSORPTION CHILLER
    Kwon, Hyun Min
    Kim, Jeong Ho
    Kim, Tong Seop
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2016, VOL 3, 2016,
  • [37] Impact of roughness on the instability of a free-cooling granular gas
    Garzo, Vicente
    Santos, Andres
    Kremer, Gilberto M.
    PHYSICAL REVIEW E, 2018, 97 (05)
  • [38] Operational experience with an innovative gas turbine inlet air-cooling system
    Prelipceanu, A.
    Bies, D.
    VGB PowerTech, 2004, 84 (08): : 64 - 70
  • [39] Turbine Inlet Air Cooling for Industrial and Aero-derivative Gas Turbine in Malaysia Climate
    Nordin, A.
    Salim, D. A.
    Othoman, M. A.
    Kamal, S. N. Omar
    Tam, Danny
    Yusof, M. K. Y.
    2017 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL, INDUSTRIAL AND ENERGY ENGINEERING (EI2E 2017), 2017, 104
  • [40] THERMODYNAMIC ANALYSIS OF GAS TURBINE PERFORMANCE WITH DIFFERENT INLET AIR COOLING TECHNIQUES
    Pereira dos Santos, Ana Paula
    de Andrade, Claudia Regina
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 3, 2012, : 79 - 89