A novel free-cooling scheme for combustion turbine inlet air cooling

被引:0
|
作者
Zamzann, Montaser M. [1 ]
Ai-Amiri, Abdalla M. [2 ]
机构
[1] Abu Dhabi Co Onshore Oil Operat ADCO, Abu Dhabi, U Arab Emirates
[2] United Arab Emirates Univ, Dept Mech Engn, Al Ain, U Arab Emirates
关键词
free cooling; cooling tower; combustion turbine inlet air cooling;
D O I
10.1115/1.2749287
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Free cooling is a well-known concept in the HVAC industry in which the cold water produced by a cooling tower is used directly to satisfy the requirement of the cooling load without assistance by the chiller; this concept, however is not reported in the turbine inlet air-cooling applications. Free cooling works well as long as the ambient wet bulb temperature (WBT) is sufficiently low to produce cold water at the required temperature, but once WBT reaches its threshold value (hence, free-cooling mode is ceased) and the chiller kicks off working under its normal mode of operation, i.e., free cooling is either enabled or disabled. The proposed system in this paper provides, in addition to the above modes of operation, a novel mode that utilizes the cooling tower as a primary source of cooling simultaneously with the chiller that serves as a secondary source at elevated WBT This new feature significantly reduces the yearly operating hours of the chiller and possibly its size, depending on the desired inlet air temperature, actual weather conditions, and design WBT Chiller size can vary between 0% and 100% as compared to a similar classical chiller system with significant reduction in the operating hours. The proposed system consists basically of chiller cooling tower, cooling coils, interconnecting piping, and controls. The arrangement of the system equipment changes with the operation modes in two configurations: dual water circulation loops and single water circulation loop. In the dual-loop configuration, the system has two separate loops such that the evaporator and the cooling coils are tied in one loop, while the cooling tower and condenser in the other loop; whereas in the single-loop configuration, all equipment is connected in series in one water circulation loop. This paper presents the major equipment and characteristics of the novel chiller scheme. In addition, the study outlines the potential reduction in the chiller load, size, and operating hours under a generalized weather envelope. The paper portrays the feasibility of using the proposed cooling scheme for turbine inlet air cooling.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A novel free-cooling scheme for combustion turbine inlet air cooling
    Zarnzarn, Montaser M.
    Ai-Arniri, Abdalla M.
    PROCEEDINGS OF THE ASME TURBO EXPO, VOL 3, 2007, : 701 - 709
  • [2] Turbine inlet air cooling
    Stewart Jr., William E.
    ASHRAE Journal, 1998, 40 (09):
  • [3] Turbine inlet air cooling
    Stewart, WE
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1998, 40 (09): : 32 - +
  • [4] Impact of climate on the economics of combustion turbine inlet air cooling
    Brown, D.R.
    Katipamula, S.
    Konynenbelt, J.H.
    International Journal of Global Energy Issues, 1997, 9 (03) : 171 - 182
  • [5] Combustion turbine inlet air cooling - Check your design point
    Kraft, JE
    POWER ENGINEERING, 2004, 108 (05) : 40 - +
  • [6] Systematic assessment of combustion turbine inlet air-cooling techniques
    Al-Amiri, AM
    Zamzam, MM
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 159 - 169
  • [7] Inlet air cooling systems for gas turbine
    1600, Japan Society of Mechanical Engineers (79):
  • [8] Test protocols for combustion turbine inlet cooling foggers
    Levine, Philip
    Angello, Leonard C.
    Proceedings of the ASME Turbo Expo 2005, Vol 5, 2005, : 435 - 443
  • [9] Potential for free-cooling by ventilation
    Ghiaus, Cristian
    Allard, Francis
    SOLAR ENERGY, 2006, 80 (04) : 402 - 413
  • [10] Impact of inlet air cooling on gas turbine performance
    Pyzik, Ewa
    Jarzebowski, Szymon
    Miller, Andrzej
    JOURNAL OF POWER TECHNOLOGIES, 2012, 92 (04): : 249 - 257