Recent progress in percutaneous coronary intervention: evolution of the drug-eluting stents, focus on the XIENCE V drug-eluting stent

被引:50
|
作者
Doostzadeh, Julie [1 ]
Clark, Lee N. [1 ]
Bezenek, Susan [1 ]
Pierson, Wesley [1 ]
Sood, Poornima R. [1 ]
Sudhir, Krishnankutty [1 ]
机构
[1] Abbott Vasc Inc, Dept Clin Sci, Santa Clara, CA 95054 USA
关键词
bare metal stents; clinical trial design; coronary stent; percutaneous coronary intervention; stent thrombosis; BARE-METAL STENTS; CLINICAL FOLLOW-UP; DE-NOVO LESIONS; ARTERY LESIONS; RANDOMIZED-TRIAL; STRUT THICKNESS; DOUBLE-BLIND; BALLOON ANGIOPLASTY; POOLED ANALYSIS; SLOW-RELEASE;
D O I
10.1097/MCA.0b013e328333f550
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although originally the practice of using balloon catheters proved successful in the short term, the long-term prognosis was less promising because of restenosis, which occurred in >= 30% of patients. This prompted the development of new techniques and mechanical adjuncts, or stents, to maintain lumen patency after balloon angioplasty. Bare metal stents (BMS), the first type of stent used in percutaneous coronary intervention, were designed to address the issues met by balloon angioplasty. BMS reduced the angiographic and clinical restenosis rates in de novo lesions compared to percutaneous transluminal coronary angioplasty alone and decreased the need for emergency coronary artery bypass graft surgery. BMS substantially reduced the incidence of abrupt artery closure, but restenosis still occurred after 6 months in about 20% of cases, necessitating repeat procedures. Drug-eluting stents (DES) improved on the principle of BMS by also delivering drugs locally to inhibit neointimal hyperplasia. DES greatly reduced the incidence of restenosis and resulted in a better safety profile as compared to radiation or systemic drug administration. These advantages and a lower cost compared to surgical interventions make DES an attractive option to treat coronary artery disease. Currently, five DES are available in the USA: the CYPHER sirolimus-eluting stent from Cordis (approved by FDA on 24 April 2003), the TAXUS Express(2) and Liberte paclitaxel-eluting stents from Boston Scientific (approved by FDA on 4 March 2004 and 10 October 2008, respectively) (hereafter TAXUS Express is referred to as TAXUS), the ENDEAVOR zotarolimus-eluting stent from Medtronic (approved by FDA on 1 February 2008), and the XIENCE V everolimus-eluting stent from Abbott Vascular (approved by FDA on 2 July 2008). Following the approval of CYPHER and TAXUS, the clinical data suggested a potential small increase in the rate of stent thrombosis (ST) in DES compared with BMS after implantation. To determine the differences in ST and other rare events between different stents, some modifications have been made to DES clinical trial design, and postmarket surveillance programs have been included to further evaluate the safety and efficacy of each DES. In this review, we will discuss the key clinical outcomes of DES clinical trials, design and key features of the current coronary stents, and major clinical development programs. Postmarket trials, designed to establish long-term safety around ST and other rare clinical events, are also discussed. The future of DES design technologies will also be outlined. Coron Artery Dis 21:46-56 (C) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:46 / 56
页数:11
相关论文
共 50 条
  • [21] Improved clinical outcome with biodegradable polymer drug-eluting stents compared to durable polymer drug-eluting stents for primary percutaneous coronary intervention
    Andriyati, Ratna
    Firman, Doni
    Kurniawati, Yovi
    Alkatiri, Amir Aziz
    Pranata, Raymond
    Muliawan, Hary Sakti
    Rossimarina, Vienna
    Soerianata, Sunarya
    [J]. POSTGRADUATE MEDICAL JOURNAL, 2021, 97 (1152) : 638 - 643
  • [22] Recent developments in drug-eluting stents
    Yue Li
    Ravinay Bhindi
    Levon M. Khachigian
    [J]. Journal of Molecular Medicine, 2011, 89 : 545 - 553
  • [23] Drug-eluting stents in vascular intervention
    Fattori, R
    Piva, T
    [J]. LANCET, 2003, 361 (9353): : 247 - 249
  • [24] Recent developments in drug-eluting stents
    Li, Yue
    Bhindi, Ravinay
    Khachigian, Levon M.
    [J]. JOURNAL OF MOLECULAR MEDICINE-JMM, 2011, 89 (06): : 545 - 553
  • [25] Attenuated coronary collateral function after drug-eluting stent implantation - A new downside of drug-eluting stents?
    Kern, Morton J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (01) : 21 - 22
  • [26] Hybrid strategy of a bare metal stent combined with a drug-eluting stent versus exclusive drug-eluting stent implantation for multivessel percutaneous coronary intervention
    Syed, Asmir I.
    Ben-Dor, Itsik
    Li, Yanlin
    Collins, Sara D.
    Torguson, Rebecca
    Wakabayashi, Kohei
    Gonzalez, Manuel A.
    Maluenda, Gabriel
    Delhaye, Cedric
    Belle, Loic
    Gaglia, Michael A., Jr.
    Xue, Zhenyi
    Kaneshige, Kimberly
    Bernardo, Nelson
    Kent, Kenneth M.
    Suddath, William O.
    Satler, Lowell F.
    Pichard, Augusto D.
    Lindsay, Joseph
    Waksman, Ron
    [J]. EUROINTERVENTION, 2011, 6 (09) : 1085 - 1090
  • [27] Comparison of drug-eluting balloon with repeat drug-eluting stent for recurrent drug-eluting stent in-stent restenosis
    Wang, Guozhong
    Zhao, Quanming
    Chen, Qing
    Zhang, Xiaoxia
    Tian, Lei
    Zhang, Xiaojiang
    [J]. CORONARY ARTERY DISEASE, 2019, 30 (07) : 473 - 480
  • [28] Drug-eluting coronary stents - Foreword
    Rahimtoola, SH
    [J]. CURRENT PROBLEMS IN CARDIOLOGY, 2006, 31 (01) : 7 - 7
  • [29] Drug-Eluting Coronary Artery Stents
    Dehmer, Gregory J.
    Smith, Kyle J.
    [J]. AMERICAN FAMILY PHYSICIAN, 2009, 80 (11) : 1245 - 1251
  • [30] Drug-eluting coronary stents - Reply
    Moliterno, DJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (22): : 2407 - 2408