Visual Perfusion-Diffusion Mismatch Is Equivalent to Quantitative Mismatch

被引:16
|
作者
Luby, Marie [1 ]
Ku, Katherine D.
Latour, Lawrence L.
Merino, Jose G. [2 ]
Hsia, Amie W. [3 ]
Lynch, John K.
Warach, Steven
机构
[1] NINDS, Sect Stroke Diagnost & Therapeut, Bethesda, MD 20892 USA
[2] Suburban Hosp Stroke Ctr, Bethesda, MD USA
[3] Washington Hosp Ctr Stroke Ctr, Bethesda, MD USA
基金
美国国家卫生研究院;
关键词
acute ischemic stroke; diffusion-weighted imaging; magnetic resonance imaging; mismatch; perfusion-weighted imaging; CEREBRAL-ISCHEMIA; STROKE; MRI; DESMOTEPLASE; RELIABILITY; WINDOW; VOLUME;
D O I
10.1161/STROKEAHA.110.603290
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-The concept of stroke MRI mismatch based on qualitative evaluation of diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) has been applied in clinical practice for several years. The benefit of MRI in providing pathological evidence of ischemia before thrombolytic treatment has been demonstrated. The purpose of this study is to determine the reliability of the qualitative method and compare it with quantitative mismatch measurement in thrombolytic-treated patients. Methods-Patients (n=70) were selected from the Lesion Evolution of Stroke and Ischemic On Neuroimaging (LESION) database if they: (1) were treated with intravenous recombinant tissue plasminogen activator; (2) had a pretreatment MRI with evaluable DWI and PWI; and (3) had acute ischemic lesion volume >10 mL on DWI as determined by core imaging laboratory measurements. Quantitative mismatch was defined as a difference of >50 mL between abnormal mean transit time and DWI volumes. Sample characteristics and postdischarge modified Rankin Scale for the positive mismatch patients were compared between the subgroups identified by qualitative versus quantitative methods. Results-Patient characteristics and thrombolytic outcomes (sex, age, National Institutes of Health Stroke Scale, mismatch volume, and modified Rankin Scale) did not differ for mismatch patients identified by qualitative versus quantitative methods. Qualitative mismatch selection among neurologists had a high sensitivity (0.82), specificity (0.80), accuracy (0.81), and positive predictive value (0.88) compared with quantitative measurements. Conclusions-We observed that qualitative evaluation of mismatch identified the same thrombolytic-treated patients compared with retrospective quantitative mismatch measurements. (Stroke. 2011;42:1010-1014.)
引用
收藏
页码:1010 / 1014
页数:5
相关论文
共 50 条
  • [1] Etiology of perfusion-diffusion mismatch
    Restrepo, L
    Jacobs, MA
    Barker, PB
    Beauchamp, NJ
    Wityk, RJ
    [J]. STROKE, 2003, 34 (01) : 261 - 261
  • [2] Standardizing quantitative and qualitative perfusion-diffusion mismatch assessment
    Butcher, Ken
    Parsons, Mark
    Allport, Louise
    Lee, Sang Bong
    Barber, Peter A.
    Tress, Brian
    Donnan, Geoff
    Davis, Stephen
    [J]. STROKE, 2007, 38 (02) : 497 - 497
  • [3] Rapid assessment of perfusion-diffusion mismatch
    Butcher, Ken
    Parsons, Mark
    Allport, Louise
    Lee, Sang Bong
    Barber, P. Alan
    Tress, Brian
    Donnan, Geoffrey A.
    Davis, Stephen M.
    [J]. STROKE, 2008, 39 (01) : 75 - 81
  • [4] Refining the perfusion-diffusion mismatch hypothesis
    Butcher, KS
    Parsons, M
    MacGregor, L
    Barber, PA
    Chalk, J
    Bladin, C
    Levi, C
    Kimber, T
    Schultz, D
    Fink, J
    Tress, B
    Donnan, G
    Davis, S
    [J]. STROKE, 2005, 36 (06) : 1153 - 1159
  • [5] Visual Assessment of Perfusion-Diffusion Mismatch Is Inadequate to Select Patients for Thrombolysis
    Campbell, Bruce C. V.
    Christensen, Soren
    Foster, Sarah J.
    Desmond, Patricia M.
    Parsons, Mark W.
    Butcher, Kenneth S.
    Barber, P. Alan
    Levi, Christopher R.
    Bladin, Christopher F.
    Donnan, Geoffrey A.
    Davis, Stephen M.
    [J]. CEREBROVASCULAR DISEASES, 2010, 29 (06) : 592 - 596
  • [6] Clinical applicability and the perfusion-diffusion mismatch theory
    Harrer, Judith U.
    [J]. NEUROLOGY, 2010, 75 (12) : 1034 - 1035
  • [7] Susceptibility-Diffusion Mismatch in Hyperacute Stroke: Correlation with Perfusion-Diffusion Mismatch and Clinical Outcome
    Dejobert, Maelle
    Cazals, Xavier
    Annan, Mariam
    Debiais, Severine
    Lauvin, Marie-Agnes
    Cottier, Jean-Philippe
    [J]. JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2016, 25 (07): : 1760 - 1766
  • [8] Significance of the perfusion-diffusion mismatch in chronic cerebral ischemia
    Surikova, Irina
    Meisel, Stefanie
    Siebler, Mario
    Wittsack, Hans-Jorg
    Seitz, Rudiger J.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 771 - 778
  • [9] The frequency of perfusion-diffusion mismatch decreases with objective definition
    Butcher, KS
    Parsons, M
    Barber, A
    Newcastle, HH
    Levi, C
    Chalk, J
    Read, S
    Schultz, D
    Bladin, C
    Desmond, P
    Tress, B
    Donnan, G
    Davis, S
    [J]. STROKE, 2004, 35 (01) : 259 - 259
  • [10] Translational perspectives on perfusion-diffusion mismatch in ischemic stroke
    Campbell, Bruce C. V.
    Macrae, I. Mhairi
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2015, 10 (02) : 153 - 162