Synchronous self-elimination of autocorrelation interference in Fourier-domain optical coherence tomography

被引:26
|
作者
Ai, J [1 ]
Wang, LHV [1 ]
机构
[1] Texas A&M Univ, Opt Imaging Lab, Dept Biomed Engn, College Stn, TX 77843 USA
关键词
D O I
10.1364/OL.30.002939
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have developed a new algorithm and configuration for self-eliminating the autocorrelation of the object wave in Fourier-domain optical coherence tomography. A self-interferogram of the object wave is acquired synchronously with the standard interferogram of the recombined object and reference waves. The former is then subtracted from the latter after Fourier transformation. The algorithm is validated by numerical simulation and by experimental measurement of a U.S. Air Force target and a feline eye. (c) 2005 Optical Society of America.
引用
收藏
页码:2939 / 2941
页数:3
相关论文
共 50 条
  • [1] Fourier phase in Fourier-domain optical coherence tomography
    Uttam, Shikhar
    Liu, Yang
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (12) : 2286 - 2306
  • [2] Pachymetric mapping with Fourier-domain optical coherence tomography
    Li, Yan
    Tang, Maolong
    Zhang, Xinbo
    Salaroli, Camila H.
    Ramos, Jose L.
    Huang, David
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05): : 826 - 831
  • [3] Influence and compensation of autocorrelation terms in depth-resolved spectroscopic Fourier-domain optical coherence tomography
    Steiner, Patrick
    Meier, Christoph
    Koch, Volker M.
    [J]. APPLIED OPTICS, 2010, 49 (36) : 6917 - 6923
  • [4] Time-domain interpolation for Fourier-domain optical coherence tomography
    Zhang, Yudong
    Li, Xiqi
    Wei, Ling
    Wang, Kai
    Ding, Zhihua
    Shi, Guohua
    [J]. OPTICS LETTERS, 2009, 34 (12) : 1849 - 1851
  • [5] Characterization of coated optical fibers by Fourier-domain optical coherence tomography
    Jasapara, J
    Wielandy, S
    [J]. OPTICS LETTERS, 2005, 30 (09) : 1018 - 1020
  • [6] Macular thickness of Chinese with fourier-domain optical coherence tomography
    Yu Weihong
    Zheng Lin
    Dai Rongping
    Zhang Zhiqiao
    Dong Fangtian
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (01) : E104 - E105
  • [7] Corneal power measurement with Fourier-domain optical coherence tomography
    Tang, Maolong
    Chen, Alex
    Li, Yan
    Huang, David
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2115 - 2122
  • [8] Reproducibility of intracoronary Fourier-domain optical coherence tomography analysis
    Orii, M.
    Kubo, T.
    Kitabata, H.
    Ishibashi, K.
    Yamano, T.
    Tanimoto, T.
    Ino, Y.
    Yamaguchi, T.
    Imanishi, T.
    Akasaka, T.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 1000 - 1000
  • [9] Fourier-domain optical coherence tomography: next step in optical imaging
    Wojtkowski, M
    Kowalczyk, A
    Targowski, P
    Gorczynska, I
    [J]. OPTICA APPLICATA, 2002, 32 (04) : 569 - 580
  • [10] In vitro validation of new Fourier-domain optical coherence tomography
    Tahara, Satoko
    Bezerra, Hiram G.
    Baibars, Motaz
    Kyono, Hiroyuki
    Wang, Wei
    Pokras, Stan
    Mehanna, Emile
    Petersen, Christopher L.
    Costa, Marco A.
    [J]. EUROINTERVENTION, 2011, 6 (07) : 875 - 882