Very low tidal volume, high-frequency ventilation in atrial fibrillation ablation: a systematic review

被引:8
|
作者
Kadado, Anis John [1 ]
Gobeil, Kyle [1 ]
Fakhoury, Fadi [2 ]
Pervaiz, Abdullah [1 ]
Chalhoub, Fadi [1 ]
机构
[1] UMass Chan Med Sch Baystate, Dept Cardiol, 759 Chestnut St, Springfield, MA 01199 USA
[2] Ctr Hosp Univ Caremeau, Dept Anesthesiol & Pain Management, Nimes, France
关键词
Atrial fibrillation ablation; High-frequency jet ventilation; Low tidal volume; PULMONARY VEIN ISOLATION; CATHETER STABILITY; CONTACT FORCE; RESPIRATION; IMPROVES;
D O I
10.1007/s10840-022-01123-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Ventilation strategies in atrial fibrillation ablation affect procedure outcomes by influencing catheter stability. Studies have highlighted favorable atrial fibrillation (AF) ablation outcomes with the use of high-frequency jet ventilation (HFJV) which has been shown to improve lesion durability, energy delivery, and tissue contact. However, this mode of ventilation is not readily available. In this systematic review, we highlight the available data on the use of very low tidal volume, high-frequency ventilation using standard ventilators that aim to provide settings similar to HFJV during AF ablations. Methods Using a combination of search terms in databases and manual searches in bibliographies of identified articles, we reviewed all published data reported in the English language on the use of very low tidal volume with high-frequency ventilation during atrial fibrillation ablation. Results A total of 4 manuscripts were identified; 3 cohort studies and 1 case report. The utilization of standard ventilators with a high-frequency, very low tidal volume ventilation strategy appears to closely mimic the catheter stability benefits that HFJV ventilators provide. Across the 3 cohort identified studies, the use of this ventilation strategy was associated with improved catheter stability, tissue contact, and a decrease in radiofrequency time. No increased risk was identified compared to standard ventilation. Conclusion With a purpose of limiting thoracic excursion and cardiac movement, limited and sparse studies have shown improved outcomes with a very low tidal volume, high-frequency ventilation strategy. Additional studies are needed to solidify this easily accessible and widely available mode of ventilation.
引用
收藏
页码:539 / 543
页数:5
相关论文
共 50 条
  • [41] HIGH-FREQUENCY VENTILATION - A REVIEW
    CHANG, HK
    HARF, A
    [J]. RESPIRATION PHYSIOLOGY, 1984, 57 (02): : 135 - 152
  • [42] Hybrid ablation for atrial fibrillation: a systematic review
    Mindy Vroomen
    Laurent Pison
    [J]. Journal of Interventional Cardiac Electrophysiology, 2016, 47 : 265 - 274
  • [43] Hybrid ablation for atrial fibrillation: a systematic review
    Vroomen, Mindy
    Pison, Laurent
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 47 (03) : 265 - 274
  • [44] Curative ablation for atrial fibrillation: A systematic review
    Gjesdal, Knut
    Vist, Gunn E.
    Bugge, Einar
    Rossvoll, Ole
    Johansen, Marit
    Norderhaug, Inger
    Ohm, Ole-J
    [J]. SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2008, 42 (01) : 3 - 8
  • [45] A Laboratory Study Of Measured Pressures And Tidal Volume During High-Frequency Oscillatory Ventilation
    Wong, R.
    Deakers, T.
    Hotz, J.
    Khemani, R. G.
    Ross, P. A.
    Newth, C.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [46] The Effect of Piston Position on Tidal Volume Delivery during High-Frequency Oscillatory Ventilation
    Ahmed, A.
    Custer, J. W.
    Mulreany, D. G.
    Kaczka, D. W.
    Simon, B. A.
    Easley, R. B.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [47] On the safety and efficacy of high-frequency jet ventilation during posterior left atrial ablation
    Goode, Joseph S., Jr.
    Ranier, Renee L.
    Buffington, Charles W.
    Klain, Miroslav M.
    Schwartzman, David
    [J]. HEART RHYTHM, 2011, 8 (08) : E1 - E1
  • [48] EXPERIENCE OF ATRIAL FIBRILLATION ABLATION IN A LOW VOLUME CENTRE
    Hanley, A.
    Cronin, E. M.
    Galligan, A. M.
    Begg, S.
    Fahy, G. J.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S406 - S406
  • [49] DELIVERED VOLUME DURING HIGH-FREQUENCY VENTILATION
    BRUSASCO, V
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1989, 33 : 70 - 71
  • [50] THE HAYEK OSCILLATOR - NOMOGRAMS FOR TIDAL VOLUME AND MINUTE VENTILATION USING EXTERNAL HIGH-FREQUENCY OSCILLATION
    PETROS, AJ
    FERNANDO, SSD
    SHENOY, VS
    ALSAADY, NM
    [J]. ANAESTHESIA, 1995, 50 (07) : 601 - 606