Rapid Injection Linear Dichroism for Studying the Kinetics of Biological Processes

被引:12
|
作者
Hicks, Matthew R. [2 ,3 ]
Rodger, Alison [2 ,3 ]
Lin, Yu-pin [1 ]
Jones, Nykola C. [4 ]
Hoffmann, Soren Vronning [4 ]
Dafforn, Timothy R. [1 ]
机构
[1] Univ Birmingham, Sch Biosci, Birmingham B15 2TT, W Midlands, England
[2] Univ Warwick, Dept Chem, Coventry CV4 7AL, W Midlands, England
[3] Univ Warwick, Warwick Ctr Analyt Sci, Coventry CV4 7AL, W Midlands, England
[4] Aarhus Univ, Inst Storage Ring Facil ISA, Dept Phys & Astron, DK-8000 Aarhus C, Denmark
基金
英国工程与自然科学研究理事会;
关键词
SYNCHROTRON-RADIATION; CONFORMATIONAL-CHANGE; MEMBRANE-INSERTION; DNA-MOLECULES; BOUND GTP; FLOW; ORIENTATION; BINDING;
D O I
10.1021/ac300842h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Linear dichroism is defined as the differential absorbance of linearly polarized light oriented in two orthogonal directions by an aligned sample. The measurement of a linear dichroism (LD) spectrum of a sample provides two key pieces of structural information. First, that the sample and the chromophores within the sample are able to align. Second, given knowledge of the transition polarization directions of the chromophores, the orientation of the chromophores within the aligned sample can be resolved. It has been shown that LD can provide unique information on the structure of some of the more challenging biomolecular complexes. This has included macromolecular protein and peptide fibers such as actin, tubulin, and amyloids as well as protein-membrane complexes and DNA-protein complexes. Much of this work has been enabled by the development of a low volume Couette flow cell that efficiently aligns long molecules in solution. However, the current Couette system is inherently complex to assemble for each experiment and hence not suited to measurement of rapid reactions. In this paper we detail the development of the first rapid injection LD cell. The system utilizes a conventional stopped-flow injection system coupled to a modified low volume Couette cell, where a narrow bore capillary replaces the normal solid central rod. The system is shown to have similar optical characteristics to the conventional LD Couette flow cell but with the added benefit of a much shorter dead time (0.60 s compared to similar to 60). The rapid injection Couette cell has been used to measure the degradation of DNA by DNA exonuclease I, providing data that would not be available using a conventional system.
引用
收藏
页码:6561 / 6566
页数:6
相关论文
共 50 条
  • [1] LINEAR DICHROISM OF BIOLOGICAL CHROMOPHORES
    HOFRICHTER, J
    EATON, WA
    ANNUAL REVIEW OF BIOPHYSICS AND BIOENGINEERING, 1976, 5 : 511 - 560
  • [2] INSTALLATION FOR STUDYING KINETICS OF METALLURGICAL PROCESSES
    LAGUNOV, YV
    RUDENKO, VK
    TITOV, AK
    VLASOV, VN
    STEEL IN THE USSR, 1974, 4 (03): : 205 - 206
  • [3] Technical developments in linear dichroism of biological molecules
    不详
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2005, 34 (06): : 612 - 612
  • [4] High-resolution, rapid image acquisition for studying biological structures and dynamic cellular processes
    Alan Kidger
    Nature Methods, 2006, 3 (7) : iii - iv
  • [5] Restriction enzyme kinetics monitored by UV linear dichroism
    Hicks, Matthew R.
    Rodger, Alison
    Thomas, Christopher M.
    Batt, Sarah M.
    Dafforn, Timothy R.
    BIOCHEMISTRY, 2006, 45 (29) : 8912 - 8917
  • [6] Flow linear dichroism assay for kinetics of endonuclease reactions
    Yakubovskaya, EA
    Gololobov, GV
    Kudelina, IA
    Smirnov, IV
    Gabibov, AG
    MOLECULAR BIOLOGY, 1996, 30 (06) : 830 - 833
  • [7] NEW OPTICAL METHODS OF STUDYING RAPID PROCESSES
    FABELINSKII, IL
    SOVIET PHYSICS USPEKHI-USSR, 1971, 14 (03): : 341 - +
  • [9] Protein nanoarrays developed for studying biological processes
    不详
    MRS BULLETIN, 2002, 27 (04) : 290 - 290
  • [10] FAST MIXING APPARATUS FOR STUDYING RAPID REACTION KINETICS
    THOMPSON, R
    GORDON, G
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1964, 41 (07): : 480 - &