An irreversible reduction peak of oxymyoglobin (MbO(2)) was observed on the bare glassy carbon electrode (GCE) in acetate buffer solution under atmospheric conditions. It is the reduction of bonded oxygen in Mb, but not the heme Fe(III)/Fe(II) redox couple that underwent electrochemical reaction on the electrode. The peak current achieved a maximum value in acetate buffer solution of pH 4.0. The peak potential was pH dependent, suggesting that the proton was involved in the electrochemical reaction. Furthermore, the peak current was linearly related to the concentration of myoglobin in the range of 2.5 x 10(-8) similar to 1.0 x 10(-6) mol.L-1 with a detection limit of 5 x 10(-9) mol.L-1.
引用
收藏
页码:83 / 87
页数:5
相关论文
共 50 条
  • [21] AMPEROMETRIC DETERMINATION OF PROPANTHELINE BROMIDE IN A FLOWING STREAM AT THE GLASSY-CARBON ELECTRODE
    SHAH, MH
    STEWART, JT
    [J]. JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1985, 68 (02): : 165 - 167
  • [22] AMPEROMETRIC DETERMINATION OF GUANETHIDINE SULFATE IN A FLOWING STREAM AT THE GLASSY-CARBON ELECTRODE
    STEWART, JT
    SHAH, MH
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1984, 20 (1-2) : 65 - 71
  • [23] Electrochemical reduction and voltammetric determination of metronidazole at a nanomaterial thin film coated glassy carbon electrode
    Lu, SF
    Wu, KB
    Dang, XP
    Hu, SS
    [J]. TALANTA, 2004, 63 (03) : 653 - 657
  • [24] Amperometric determination of dopamine on a glassy carbon electrode chemically modified with cobalt pentacyanonitrosylferrate
    Bari, Mahmoud Rezazadeh
    Sabzi, Reza Emamali
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2008, 20 (05) : 3357 - 3363
  • [25] AMPEROMETRIC DETERMINATION OF HYDRALAZINE HYDROCHLORIDE IN A FLOWING STREAM AT THE GLASSY-CARBON ELECTRODE
    SHAH, MH
    STEWART, JT
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (07) : 989 - 991
  • [26] AMPEROMETRIC DETERMINATION OF PHENAZOPYRIDINE HYDROCHLORIDE IN A FLOWING STREAM AT THE GLASSY-CARBON ELECTRODE
    BELAL, F
    [J]. JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1985, 68 (06): : 1207 - 1209
  • [27] Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode
    Xu, Guang-Ri
    Xu, Guifang
    Xu, Ming-Lu
    Zhang, Zhengqing
    Tian, Yuan
    Cho, Han Nim
    Lee, Won-Yong
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (02): : 415 - 419
  • [28] Electrochemical behavior of paclitaxel and its determination at glassy carbon electrode
    Gowda, Jayant I.
    Nandibewoor, Sharanappa T.
    [J]. ASIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 9 (01) : 42 - 49
  • [29] Fast Electrochemical Determination of Imidacloprid at an Activated Glassy Carbon Electrode
    Si, Weimeng
    Han, Zhen
    Lei, Wu
    Wu, Qiuju
    Zhang, Yuehua
    Xia, Mingzhu
    Hao, Qingli
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (01) : B9 - B13
  • [30] Amperometric nonenzymatic determination of glucose based on a glassy carbon electrode modified with nickel(II) oxides and graphene
    Xiaohua Zhu
    Qifang Jiao
    Chuyi Zhang
    Xiaoxi Zuo
    Xin Xiao
    Yong Liang
    Junmin Nan
    [J]. Microchimica Acta, 2013, 180 : 477 - 483