Facial dimensions and predictors of fit for half-mask respirators in Koreans

被引:22
|
作者
Han, DH [1 ]
Choi, KL
机构
[1] Inje Univ, Dept Ind Hlth & Safety Engn, Gimhae 621749, Gyeongnam Do, South Korea
[2] Inje Univ, Dept Data Sci, Gyeongnam Do, South Korea
来源
AIHA JOURNAL | 2003年 / 64卷 / 06期
关键词
facial dimensions; fit factor; half-mask respirator; Korean;
D O I
10.1080/15428110308984877
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated the relationship between facial dimensions and the fit of half-mask respirators using fit factors and selected good facial dimension predictor(s) of fit for designing respirators for Korean workers. Three different brands of half-mask respirators-YS, SG, and 3M-were fit-tested on 112 men and 38 women using TSI Portacount 8020(R), and fit factors were determined. Before fit-testing, 10 facial dimensions were measured. Data were analyzed by descriptive statistics, Pearson's correlation analysis, and quadratic polynomial regression analysis with log-transformed fit factors (LNFF). However, some of the relationships between LNFF and facial dimensions in brand/gender subgroups were found to be curvilinear rather than linear. Because this result indicated that a multiple polynomial regression model including quadratic terms might be more appropriate than a multiple linear regression, data were also analyzed with a quadratic term by examination of the coefficient of partial correlation. No common facial dimension variables were found to be significant for all nine brand/gender subgroups, but the coefficient of regression for the linear term of the bitragion-menton arc was significant in five of nine brand/gender subgroups including male subjects of all three respirator brands. The 3M mask had the highest coefficient of determination values compared with other brands. Using the quadratic term for the 3M mask, face width (bizygomatic breadth) and nose protrusion were good predictors of half-mask fit. In four of nine brand/gender subgroups, nose protrusion was a good predictor of fit through analysis using a quadratic term. Results indicate that face width, bitragion-menton arc, and nose protrusion should be preferentially considered when designing a half-mask respirator for Korean workers.
引用
收藏
页码:815 / 822
页数:8
相关论文
共 50 条
  • [41] Characteristics Associated With Health Care Worker Knowledge and Confidence in Elastomeric Half-Mask Respirator Use
    Thurman, Paul
    Zhuang, Eileen
    Chen, Hegang H.
    McClain, Caitlin
    Sietsema, Margaret
    Fernando, Rohan
    McDiarmid, Melissa A.
    Hines, Stella E.
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2022, 64 (09) : 802 - 807
  • [42] Laboratory Evaluation of the Particle Size Effect on the Performance of an Elastomeric Half-mask Respirator against Ultrafine Combustion Particles
    He, Xinjian
    Grinshpun, Sergey A.
    Reponen, Tiina
    Yermakov, Michael
    Mckay, Roy
    Haruta, Hiroki
    Kimura, Kazushi
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 2013, 57 (07): : 884 - 897
  • [43] Fit Characteristics of N95 Filtering Facepiece Respirators and the Accuracy of the User Seal Check among Koreans
    Huh, Yu Jung
    Jeong, Hye Min
    Lim, Juhye
    Park, Ha Yan
    Kim, Min Young
    Oh, Hong Sang
    Huh, Kyungmin
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2018, 39 (01): : 104 - 107
  • [44] Assessment of half-mask elastomeric respirator and powered air-purifying respirator reprocessing for an influenza pandemic
    Lawrence, Caryn
    Harnish, Delbert A.
    Sandoval-Powers, Megan
    Mills, Devin
    Bergman, Michael
    Heimbuch, Brian K.
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2017, 45 (12) : 1324 - 1330
  • [45] MEASUREMENT OF 3-D FACIAL CONTOURS FOR THE DESIGN OF HALF-FACE RESPIRATORS
    YATAPANAGE, KG
    POST, K
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1992, 53 (01): : 19 - 26
  • [46] A Must for NIOSH: Certify Fit Performance of the Half Mask Particulate Respirator
    Lofgren, Don J.
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2012, 9 (12) : D191 - D195
  • [47] Effects of Breathing Frequency and Flow Rate on the Total Inward Leakage of an Elastomeric Half-Mask Donned on an Advanced Manikin Headform
    He, Xinjian
    Grinshpun, Sergey A.
    Reponen, Tiina
    McKay, Roy
    Bergman, Michael S.
    Zhuang, Ziqing
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 2014, 58 (02): : 182 - 194
  • [48] WORKPLACE FIELD TESTING OF A DISPOSABLE NEGATIVE-PRESSURE HALF-MASK DUST RESPIRATOR (3M-8710)
    WALLIS, G
    MENKE, R
    CHELTON, C
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1993, 54 (10): : 576 - 583
  • [49] Study on the relationship between the fitness of three types of N95 respirators and facial dimensions
    Wang, Guifang
    Luo, Changwei
    Cui, Can
    Huang, Jing
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2024, 21 (05) : 319 - 325
  • [50] The effect of gender and respirator brand on the association of respirator fit with facial dimensions
    Oestenstad, R. Kent
    Elliott, Leshan J.
    Beasley, T. Mark
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2007, 4 (12) : 923 - 930