Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens

被引:71
|
作者
Munoz, Gonzalo [1 ,4 ]
Albarran-Diego, Cesar
Ferrer-Blasco, Teresa [1 ,2 ,3 ]
Sakla, Hani E.
Garcia-Lazaro, Santiago [1 ,2 ,3 ]
机构
[1] Univ Valencia, Clin Oftalmol Marques de Sotelo, Refract Surg Dept, Valencia 46002, Spain
[2] Univ Valencia, Hosp NISA Valencia, Valencia 46002, Spain
[3] Univ Valencia, Optometry Res Grp GIO, Valencia 46002, Spain
[4] Ebsaar Eye Surg Ctr, Dubai, U Arab Emirates
来源
关键词
QUALITY-OF-LIFE; CONTRAST SENSITIVITY; CATARACT-SURGERY; CLINICAL-TRIAL; OPTICAL-PERFORMANCE; POWER CALCULATION; OUTCOMES; RESTOR; ACUITY; REZOOM;
D O I
10.1016/j.jcrs.2011.05.045
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). SETTING: Private practice surgery center, Valencia, Spain. DESIGN: Cohort study. METHODS: Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. RESULTS: In the multifocal group, the mean binocular corrected distance visual acuity (logMAR) was -0.04 +/- 0.07 at 6 m, 0.11 +/- 0.10 at 1 m, and 0.06 +/- 0.07 at 40 cm. The defocus curve showed little intermediate vision drop off. Photopic contrast sensitivity for distance was similar to the monofocal IOL contrast sensitivity function, while photopic contrast sensitivity for near and mesopic contrast sensitivity for distance with or without glare was reduced at high frequencies. The mean patient satisfaction was 8.09 +/- 1.30 (scale 0 to 10); 84.4% of patients were completely independent of spectacles. Moderate halos, glare, and night-vision problems were reported by 6.2%, 12.5%, and 15.6% of patients, respectively. CONCLUSION: The new-generation multifocal IOL provided adequate distance, intermediate, and, to a lesser extent, near vision with high rates of spectacle freedom. Halos occurred, and other photic phenomena should be expected in a small percentage of patients.
引用
收藏
页码:2043 / 2052
页数:10
相关论文
共 50 条
  • [1] Refractive outcomes after bilateral multifocal intraocular lens implantation
    Pineda-Fernández, A
    Jaramillo, J
    Celis, V
    Vargas, J
    DiStacio, M
    Galíndez, A
    Del Valle, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03): : 685 - 688
  • [2] Visual performance after bilateral implantation of a new diffractive aspheric multifocal intraocular lens with a 3.5 D addition
    Dexl, Alois K.
    Zaluski, Serge
    Rasp, Max
    Grabner, Guenther
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (01) : 35 - 43
  • [3] Visual performance after implantation of an aspheric multifocal diffractive intraocular lens
    Akaishi, Leonardo
    Messias, Camila Brito
    de Moraes Tzelikis, Patrick Frensel
    [J]. REVISTA BRASILEIRA DE OFTALMOLOGIA, 2010, 69 (04) : 230 - 235
  • [5] Visual function after implantation of an aspheric bifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Amhaz, Hussein
    Montes-Mico, Robert
    Valcarcel, Beatriz
    Ferrer-Blasco, Teresa
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05): : 885 - 892
  • [6] Visual function after implantation of a diffractive aspheric trifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega Cueto, Luis
    Belda-Salmeron, Lurdes
    Montes-Mico, Robert
    Fernandez-Vega, Luis
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (05) : 405 - 411
  • [7] Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens
    Shimoda, Talita
    Shimoda, Gilberto
    Hida, Wilson Takashi
    Nakano, Celso Takashi
    Motta, Antonio Francisco
    Guimaraees, Aline Silva
    Tzelikis, Patrick Frensel M.
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (02) : 71 - 75
  • [8] Stereoacuity and aniseikonia after unilateral and bilateral implantation of the Array refractive multifocal intraocular lens
    Häring, G
    Gronemeyer, A
    Hedderich, J
    de Decker, W
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (08): : 1151 - 1156
  • [9] Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Albarran-Diego, Cesar
    Belda-Salmeron, Lurdes
    Montes-Mico, Robert
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (03) : 192 - 196
  • [10] Binocular function after bilateral implantation of monofocal and refractive multifocal intraocular lenses
    Arens, B
    Freudenthaler, N
    Quentin, CD
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (03): : 399 - 404