Purpose: To evaluate stereoacuity and aniseikonia in eyes with unilateral and bilateral implantation of the Allergan Array(R) refractive multifocal intraocular lens (MIOL). Setting: Department of Ophthalmology, University Hospital, Kiel, Germany. Methods: This study comprised 31 patients with a unilateral MIOL and a phakic fellow eye and 29 patients with bilateral MIOLs. in all pseudophakic eyes, an Array MIOL had been implanted between 1991 and 1994 during a prospective clinical trial. In the present study, patients were re-examined. Near and distance visual acuity were i tested; binocular functions were assessed using Bagolini lenses, the Worth 4-dot test, the Lang random-dot test, and the Titmus fly chart. Aniseikonia was evaluated using Aulhorn's phase-difference haploscope. Mean follow-up was 43 months in both groups. Results: After unilateral implantation 87.1% of patients and after bilateral implantation 93.1% of patients correctly perceived the stereograms of the Lang random-dot test. The mean subjective height of the measured Titmus fly was 4.2 cm after unilateral and 4.3 cm after bilateral implantation. The stereoacuity tests revealed no statistically significant differences between the groups. Distance and near aniseikonia were significantly less after bilateral than after unilateral implantation. Conclusion: Despite the simultaneous formation of multiple retinal images, the Array MIOL allowed good binocular vision including random-dot stereopsis. Functional aniseikonia developed but did not interfere with normal binocular vision. (C) 1999 ASCRS and ESCRS.
引用
收藏
页码:1151 / 1156
页数:6
相关论文
共 50 条
  • [1] Refractive outcomes after bilateral multifocal intraocular lens implantation
    Pineda-Fernández, A
    Jaramillo, J
    Celis, V
    Vargas, J
    DiStacio, M
    Galíndez, A
    Del Valle, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03): : 685 - 688
  • [2] Management of aniseikonia after intraocular lens implantation or refractive surgery
    Enoch, JM
    [J]. JOURNAL OF REFRACTIVE SURGERY, 1997, 13 (01): : 79 - 82
  • [3] Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    Cervino, Alejandro
    Alfonso, Jose F.
    Gonzalez-Meijome, Jose M.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (11) : 1000 - 1004
  • [4] Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens
    Munoz, Gonzalo
    Albarran-Diego, Cesar
    Ferrer-Blasco, Teresa
    Sakla, Hani E.
    Garcia-Lazaro, Santiago
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11): : 2043 - 2052
  • [5] Quality of vision after bilateral multifocal intraocular lens implantation in pregeriatric Hispanic population, after refractive lens exchange
    Alberto Nava, Jose
    Rubi Morales-Mancillas, Nallely
    Valdez, Jorge E.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [6] Refractive lens exchange with the Array multifocal intraocular lens
    Packer, M
    Fine, IH
    Hoffman, RS
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03): : 421 - 424
  • [7] Refractive lens exchange with an array multifocal intraocular lens
    Dick, HB
    Gross, S
    Tehrani, M
    Eisenmann, D
    Pfeiffer, N
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (05) : 509 - 518
  • [8] Piggyback Intraocular Lens Implantation to Correct Pseudophakic Refractive Error After Segmental Multifocal Intraocular Lens Implantation
    Venter, Jan A.
    Oberholster, Andre
    Schallhorn, Steven C.
    Pelouskova, Martina
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (04) : 234 - 239
  • [9] ANISEIKONIA AND STEREOACUITY IN PSEUDOPHAKIC PATIENTS - UNILATERAL AND BILATERAL CASES
    MIYAJIMA, H
    KATSUMI, O
    MIKI, E
    OGAWA, T
    HIROSE, T
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1302 - 1302
  • [10] THE CONTROL OF ANISEIKONIA AFTER INTRAOCULAR-LENS IMPLANTATION
    HILLMAN, JS
    HAWKSWELL, A
    [J]. TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1985, 104 : 582 - 585