Two phase flow model for the close-coupled atomization of metals

被引:0
|
作者
Miller, RS
Miller, SA
Savkar, SD
Mourer, DP
机构
[1] NUCL MET INC,CONCORD,MA 01742
[2] GE CO,CORP RES & DEV,SCHENECTADY,NY 12301
[3] GE CO,AIRCRAFT ENGINES,LYNN,MA 01904
来源
关键词
D O I
暂无
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The use of the nozzle tip static (aspiration) pressure during the flow of atomizing gas in close-coupled atomization geometries is employed widely to characterize the operable atomization regime, and, in some cases, the expected metal flow rate. A single phase flow calculation of metal flow rate using this pressure shows that the actual metal flow during atomization is not determined simply by the aspiration pressure. An improved model has been developed by applying a force balance and momentum conservation at the metal/gas interface. Combined with numerical and experimental gas flow data, the model provides a rational interpretation of the relationship between aspiration pressure and metal flow during atomization. The model also provides a physical basis for some of the commonly observed limits on the operating envelope of close-coupled atomizers and establishes a rational basis for non-metal fluid modeling of the atomization process. A variety of metal and wafer flow test data and local static and dynamic pressure measurements are presented which demonstrate the validity and limitations of the model.
引用
收藏
页码:341 / 352
页数:12
相关论文
共 50 条
  • [31] Experimental study of flow dynamics in close-coupled catalyst manifolds
    Persoons, T.
    Hoefnagels, A.
    Van den Bulck, E.
    INTERNATIONAL JOURNAL OF ENGINE RESEARCH, 2007, 8 (02) : 163 - 183
  • [32] Research Advances in Close-Coupled Atomizer Flow and Atomizing Mechanisms
    Min Zhang
    Zhaoming Zhang
    Qiusheng Liu
    Powder Metallurgy and Metal Ceramics, 2023, 62 : 400 - 426
  • [33] CFD-BASED NUMERICAL SIMULATION OF GAS FLOW FIELD CHARACTERISTICS IN CLOSE-COUPLED VORTICAL LOOP SLIT GAS ATOMIZATION
    Zhang, M.
    Zhang, Z. M.
    Zhang, Y. Q.
    Lu, Y. J.
    ATOMIZATION AND SPRAYS, 2021, 31 (07) : 17 - 47
  • [34] Close-coupled rows save energy
    Bean, John
    Dunlap, Kevin
    COMMUNICATIONS NEWS, 2007, 44 (04): : 38 - 39
  • [35] Pressure loss coefficient measurements of two close-coupled HVAC elbows
    Mylaram, NK
    Idem, S
    HVAC&R RESEARCH, 2005, 11 (01): : 133 - 146
  • [36] VIBRATORY RESPONSE OF CLOSE-COUPLED SYSTEMS
    MAHALINGAM, S
    JOURNAL OF SOUND AND VIBRATION, 1979, 63 (02) : 189 - 200
  • [37] Modelling of a close-coupled photovoltaic heatpump
    Underwood, CP
    Jones, AD
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 1189 - 1197
  • [38] Close-coupled gas atomization: High-frame-rate analysis of spray-cone geometry
    Mullis, Andrew M.
    Adkins, Nicholas J. E.
    Aslam, Zabeada
    McCarthy, I.
    Cochrane, Robert F.
    INTERNATIONAL JOURNAL OF POWDER METALLURGY, 2008, 44 (01): : 55 - 64
  • [39] A study of liquid metal atomization using close-coupled nozzles, Part 1: Gas dynamic behavior
    Mates, SP
    Settles, GS
    ATOMIZATION AND SPRAYS, 2005, 15 (01) : 19 - 40
  • [40] Pressure loss coefficient measurements of two close-coupled HVAC elbows
    Mylararn, NK
    Idem, S
    ASHRAE Transactions 2005, Vol 111, Pt 1, 2005, 111 : 521 - 521