Bone mineral density in the lumbar spine as determined by dual-energy X-ray absorptiometry - Comparison of whole-body scans and dedicated regional scans

被引:15
|
作者
Nysom, K
Molgaard, C
Michaelsen, KF
机构
[1] Copenhagen Univ Hosp, Juliane Marie Ctr, Sect Paediat Haematol & Oncol, Copenhagen, Denmark
[2] Royal Vet & Agr Univ, Res Dept Human Nutr, Frederiksberg, Denmark
[3] Royal Vet & Agr Univ, Ctr Adv Food Studies, Frederiksberg, Denmark
关键词
lumbar spine; bone mineral measurement; dual-energy X-ray absorptiometry; regression analysis; paediatric;
D O I
10.3109/02841859809175488
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare bone mineral in the lumbar spine as measured by either consecutive regional or whole-body dual-energy X-ray absorptiometry (DXA), and to develop models that predict regional results from whole-body results. Material and Methods: In 180 children and young adults, bone mineral in the lumbar spine was measured by a Hologic QDR-1000/W DXA scanner, using either whole-body software (which can give data for the lumbar spine subregion) or dedicated lumbar spine software. Data on 139 persons were used to compare the two methods and to develop models that predict the result of a regional scan from the result of a whole-body scan. Data on the remaining 41 persons were used to control these models. Results: Bone mineral content, bone area, and bone mineral areal density (BMDA) of the lumbar spine were measured significantly lower by whole-body scans than by regional scans (p<0.0001). The difference was larger for the lower values of bone area and BMDA. We developed models that predicted lumbar spine BMDA from whole-body results. When these models were controlled in another group, the mean error between the methods was non-significant and the error was unrelated to the BMDA value. However, the variance of the error was only minimally reduced. Conclusions: Lumbar spine bone mineral was measured significantly lower by whole-body DXA than by regional DXA. Based on local data, models were developed that removed the significant difference between the methods.
引用
收藏
页码:632 / 636
页数:5
相关论文
共 50 条
  • [31] Anomalies in the Measurement of Changes in Bone Mineral Density of the Spine by Dual-Energy X-ray Absorptiometry
    P. Tothill
    A. Avenell
    Calcified Tissue International, 1998, 63 : 126 - 133
  • [32] The Effect of Radiopharmaceutical Administration on Dual-Energy X-Ray Absorptiometry Scans
    Blake, Glen M.
    JOURNAL OF CLINICAL DENSITOMETRY, 2013, 16 (03) : 257 - 258
  • [33] LUMBAR SCANS (LS) CORRELATE WITH TOTAL-BODY SCANS (TS) FOR TOTAL BONE-DENSITY (TBD) AND FAT-PERCENT BY DUAL-ENERGY X-RAY ABSORPTIOMETRY (DEXA)
    LEUNG, D
    LINDSAY, R
    WANG, J
    PIERSON, RN
    FASEB JOURNAL, 1994, 8 (04): : A165 - A165
  • [34] Effects of metal implants on whole-body dual-energy x-ray absorptiometry measurements of bone mineral content and body composition
    Giangregorio, LM
    Webber, CE
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2003, 54 (05): : 305 - 309
  • [35] The Effect of the Lumbar Vertebral Malpositioning on one Mineral Density Measurements of the Lumbar Spine by Dual-Energy X-Ray Absorptiometry
    Izadyar, Sina
    Golbarg, Shima
    Takavar, Abbas
    Zakariaee, Seyed Salman
    JOURNAL OF CLINICAL DENSITOMETRY, 2016, 19 (03) : 277 - 281
  • [36] Volumetric measurements of bone mineral density of the lumbar spine: Comparison of three geometrical approximations using dual-energy X-ray absorptiometry (DXA)
    Schreuder, MF
    Van Driel, APG
    Van Lingen, A
    Roos, JC
    De Ridder, CM
    Manoliu, RA
    David, EFL
    Netelenbos, JC
    NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (08) : 727 - 733
  • [37] Comparison of Lumbar Spine Bone Mineral Density Using Quantitative Computed Tomography and Dual-Energy X-Ray Absorptiometry in an Ovine Model of Osteoporosis
    Bisazza, Katie
    Nelson, Brad
    Sikes, Katie
    Stewart, Holly
    Easley, Jeremiah
    JOURNAL OF BONE AND MINERAL RESEARCH, 2023, 38 : 167 - 168
  • [38] Evaluation of bone mineral density of the lumbar spine using a novel phantomless dual-energy CT post-processing algorithm in comparison with dual-energy X-ray absorptiometry
    Booz C.
    Hofmann P.C.
    Sedlmair M.
    Flohr T.G.
    Schmidt B.
    D’Angelo T.
    Martin S.S.
    Lenga L.
    Leithner D.
    Vogl T.J.
    Wichmann J.L.
    European Radiology Experimental, 1 (1)
  • [39] Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
    Forogh, B.
    Ghasemzadeh, A.
    Salimzadeh, A.
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2005, 30 (01) : 34 - 37
  • [40] Dual-Energy X-Ray Absorptiometry: Beyond Bone Mineral Density Determination
    Choi, Yong Jun
    ENDOCRINOLOGY AND METABOLISM, 2016, 31 (01) : 25 - 30