Split operator method for fluorescence diffuse optical tomography using anisotropic diffusion regularisation with prior anatomical information

被引:31
|
作者
Correia, Teresa [1 ]
Aguirre, Juan [2 ]
Sisniega, Alejandro [2 ]
Chamorro-Servent, Judit [2 ]
Abascal, Juan [2 ]
Vaquero, Juan J. [2 ]
Desco, Manuel [2 ,3 ]
Kolehmainen, Ville [4 ]
Arridge, Simon [1 ]
机构
[1] UCL, Dept Comp Sci, London WC1E 6BT, England
[2] Univ Carlos III Madrid, Dept Bioingn & Ingn Aeroespacial, E-28903 Getafe, Spain
[3] Hosp Gen Univ Gregorio Maranon, CIBER Salud Mental CIBERSAM, Unidad Med & Cirugia Expt, Madrid, Spain
[4] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
来源
BIOMEDICAL OPTICS EXPRESS | 2011年 / 2卷 / 09期
基金
英国工程与自然科学研究理事会;
关键词
IN-VIVO; MOLECULAR TOMOGRAPHY; IMAGE-RECONSTRUCTION; EDGE-DETECTION; BREAST; SCHEMES; SYSTEM;
D O I
10.1364/BOE.2.002632
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence diffuse optical tomography (fDOT) is an imaging modality that provides images of the fluorochrome distribution within the object of study. The image reconstruction problem is ill-posed and highly underdetermined and, therefore, regularisation techniques need to be used. In this paper we use a nonlinear anisotropic diffusion regularisation term that incorporates anatomical prior information. We introduce a split operator method that reduces the nonlinear inverse problem to two simpler problems, allowing fast and efficient solution of the fDOT problem. We tested our method using simulated, phantom and ex-vivo mouse data, and found that it provides reconstructions with better spatial localisation and size of fluorochrome inclusions than using the standard Tikhonov penalty term. (C) 2011 Optical Society of America
引用
收藏
页码:2632 / 2648
页数:17
相关论文
共 50 条
  • [21] Multibeam fluorescence diffuse optical tomography using upconverting nanoparticles
    Liu, Haichun
    Xu, Can T.
    Andersson-Engels, Stefan
    OPTICS LETTERS, 2010, 35 (05) : 718 - 720
  • [22] Construction of the Jacobian matrix for fluorescence diffuse optical tomography using a perturbation Monte Carlo method
    Zhang, Xiaofeng
    Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 2012, 8216
  • [23] Construction of the Jacobian matrix for fluorescence diffuse optical tomography using a perturbation Monte Carlo method
    Zhang, Xiaofeng
    MULTIMODAL BIOMEDICAL IMAGING VII, 2012, 8216
  • [24] Adaptive Speckle Reducing Anisotropic Diffusion Filter for Positron Emission Tomography Images Based on Anatomical Prior
    Alrefaya, Mousa
    2018 4TH INTERNATIONAL CONFERENCE ON COMPUTER AND TECHNOLOGY APPLICATIONS (ICCTA), 2018, : 194 - 201
  • [25] Model reduction by multiresolution method applied to fluorescence Diffuse Optical Tomography
    Frassati, Anne
    Da Silva, Anabela
    Dinten, Jean-Marc
    Georges, Didier
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 767 - +
  • [26] 3D microwave tomography of the breast using prior anatomical information
    Golnabi, Amir H.
    Meaney, Paul M.
    Paulsen, Keith D.
    MEDICAL PHYSICS, 2016, 43 (04) : 1933 - 1944
  • [27] Reconstruction of optical properties using a diffusion model for interstitial diffuse optical tomography
    Wang, Ken Kang-Hsin
    Zhu, Timothy C.
    OPTICAL METHODS FOR TUMOR TREATMENT AND DETECTION: MECHANISMS AND TECHNIQUES IN PHOTODYNAMIC THERAPY XVIII, 2009, 7164
  • [28] Multispectral guided fluorescence diffuse optical tomography using upconverting nanoparticles
    Svenmarker, Pontus
    Xu, Can T.
    Liu, Haichun
    Wu, Xia
    Andersson-Engels, Stefan
    APPLIED PHYSICS LETTERS, 2014, 104 (07)
  • [29] Assessment of using ultrasound images as prior for diffuse optical tomography regularization matrix
    Althobaiti, Murad
    Vavadi, Hamed
    Zhu, Quing
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE XII, 2017, 10059
  • [30] Fluorescence-enhanced Optical Tomography using Phase Information
    Lu, Yujie
    Sevick-Muraca, Eva M.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX, 2011, 7896