Split operator method for fluorescence diffuse optical tomography using anisotropic diffusion regularisation with prior anatomical information

被引:31
|
作者
Correia, Teresa [1 ]
Aguirre, Juan [2 ]
Sisniega, Alejandro [2 ]
Chamorro-Servent, Judit [2 ]
Abascal, Juan [2 ]
Vaquero, Juan J. [2 ]
Desco, Manuel [2 ,3 ]
Kolehmainen, Ville [4 ]
Arridge, Simon [1 ]
机构
[1] UCL, Dept Comp Sci, London WC1E 6BT, England
[2] Univ Carlos III Madrid, Dept Bioingn & Ingn Aeroespacial, E-28903 Getafe, Spain
[3] Hosp Gen Univ Gregorio Maranon, CIBER Salud Mental CIBERSAM, Unidad Med & Cirugia Expt, Madrid, Spain
[4] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
来源
BIOMEDICAL OPTICS EXPRESS | 2011年 / 2卷 / 09期
基金
英国工程与自然科学研究理事会;
关键词
IN-VIVO; MOLECULAR TOMOGRAPHY; IMAGE-RECONSTRUCTION; EDGE-DETECTION; BREAST; SCHEMES; SYSTEM;
D O I
10.1364/BOE.2.002632
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence diffuse optical tomography (fDOT) is an imaging modality that provides images of the fluorochrome distribution within the object of study. The image reconstruction problem is ill-posed and highly underdetermined and, therefore, regularisation techniques need to be used. In this paper we use a nonlinear anisotropic diffusion regularisation term that incorporates anatomical prior information. We introduce a split operator method that reduces the nonlinear inverse problem to two simpler problems, allowing fast and efficient solution of the fDOT problem. We tested our method using simulated, phantom and ex-vivo mouse data, and found that it provides reconstructions with better spatial localisation and size of fluorochrome inclusions than using the standard Tikhonov penalty term. (C) 2011 Optical Society of America
引用
收藏
页码:2632 / 2648
页数:17
相关论文
共 50 条
  • [1] Anisotropic diffusion regularization methods for diffuse optical tomography using edge prior information
    Douiri, A.
    Schweiger, M.
    Riley, J.
    Arridge, S. R.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (01) : 87 - 95
  • [2] Fluorescence diffuse optical tomography using the split Bregman method
    Abascal, J. F. P. -J.
    Chamorro-Servent, J.
    Aguirre, J.
    Arridge, S.
    Correia, T.
    Ripoll, J.
    Vaquero, J. J.
    Desco, M.
    MEDICAL PHYSICS, 2011, 38 (11) : 6275 - 6284
  • [3] Regularization in fluorescence diffuse optical tomography using prior information on the medium optical properties
    Pery, E.
    Herve, L.
    Dinten, J. M.
    Peyrin, F.
    MULTIMODAL BIOMEDICAL IMAGING V, 2010, 7557
  • [4] Fluorescence diffuse optical tomography with functional and anatomical a priori information:: feasibility study
    Lin, Y.
    Gao, H.
    Nalcioglu, O.
    Gulsen, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (18): : 5569 - 5585
  • [5] Diffuse optical tomography with a priori anatomical information
    Guven, M
    Yazici, B
    Intes, X
    Chance, B
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE V, 2003, 4955 : 634 - 646
  • [6] Diffuse optical tomography with a priori anatomical information
    Guven, M
    Yazici, B
    Intes, X
    Chance, B
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (12): : 2837 - 2858
  • [7] Fluorescence diffuse optical tomography with structural a priori information
    Lin, Yuting
    Nalcioglu, Orhan
    Gulsen, Gultekin
    MULTIMODAL BIOMEDICAL IMAGING III, 2008, 6850
  • [8] Three-Dimensional Fluorescence Diffuse Optical Tomography Using the Adaptive Spatial Prior Approach
    Pei An Lo
    Huihua Kenny Chiang
    Journal of Medical and Biological Engineering, 2019, 39 : 827 - 834
  • [9] Three-Dimensional Fluorescence Diffuse Optical Tomography Using the Adaptive Spatial Prior Approach
    Lo, Pei An
    Chiang, Huihua Kenny
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2019, 39 (06) : 827 - 834
  • [10] Three-dimensional diffuse optical tomography with a priori anatomical information
    Guven, M
    Yazici, B
    Intes, X
    Chance, B
    PHOTON MIGRATION AND DIFFUSE-LIGHT IMAGING, 2003, 5138 : 268 - 280