Predictors of edge stenosis after paclitaxel-eluting stent implantation

被引:3
|
作者
Kang, Woong Chol [1 ]
Park, Yae Min [1 ]
Shin, Kwen-Chul [1 ]
Moon, Chan Il [1 ]
Shin, Mi Seung [1 ]
Lee, Kyounghoon [1 ]
Han, Seung Hwan [1 ]
Ahn, Taehoon [1 ]
Shin, Eak Kyun [1 ]
机构
[1] Gachon Univ Med & Sci, Dept Cardiol, Gil Hosp, Inchon 405760, South Korea
关键词
edge stenosis; intravascular ultrasound; paclitaxel-eluting stent; SERIAL INTRAVASCULAR ULTRASOUND; TAXUS-II TRIAL; INTIMAL HYPERPLASIA; CORONARY INTERVENTIONS; DIABETES-MELLITUS; RESTENOSIS; RESPONSES; ANGIOPLASTY; BALLOON; IMPACT;
D O I
10.1097/MCA.0b013e328343fbff
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Although edge stenosis (ES) is a main limitation of drug-eluting stents, the predictors for ES are not well known. We evaluated the predictors for ES after paclitaxel-eluting stent implantation. Methods One hundred and eleven angina patients (64 men; 62.2 +/- 8.4 years of age) were divided into ES (n = 9) and non-ES groups (n = 102). The clinical findings, procedural factors, and intravascular ultrasound (IVUS) parameters were analyzed. Results Although clinical characteristics were not different between groups, diabetes mellitus (DM) was more common in the ES group (P = 0.002). The vessel, plaque, and lumen areas of the lesions were not different between groups; however, the vessel area of the proximal and distal reference artery was smaller in the ES group. Lesions with positive remodeling were more common in the ES group (P = 0.015). On the basis of univariate analysis, predictors of ES included DM, lesions with positive remodeling, IVUS parameters, and procedural factors. After adjusting for clinical findings, angiographic factors, and IVUS parameters, the presence of DM [odds ratio (OR): 9.20; 95% confidence interval (CI): 1.40-60.62, P = 0.021] and lesions with positive remodeling (OR: 5.93; 95% CI: 1.13-31.02, P = 0.035) were independent predictors of ES. The lumen area in the distal 1mm reference segment was a protective factor for ES (OR: 0.05; 95% CI: 0.00-0.74, P = 0.029). Conclusion The risk of ES after paclitaxel-eluting stent implantation was higher in patients who had DM and lesions with positive remodeling. Of the IVUS parameters, the lumen area in the distal 1 mm reference segment was a protective factor against ES. Coron Artery Dis 22:59-63 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 50 条
  • [31] B-type natriuretic peptide as a marker of asymptomatic re-stenosis after coronary implantation of a paclitaxel-eluting stent
    Lo Mauro, Renato
    Arcoleo, Francesco
    Lo Giudice, Angela
    Picone, Antonina
    Schirosa, Maurizio
    Raspanti, Giacinto
    Cillari, Enrico
    Enia, Francesco
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2007, 8 (12) : 1020 - 1023
  • [32] Treatment of paclitaxel-eluting stent restenosis with sirolimus-eluting stent implantation -: Angiographic and clinical outcomes
    Byrne, Robert A.
    Iijima, Raisuke
    Mehilli, Julinda
    Seyfarth, Melchior
    Schoemig, Albert
    Kastrati, Adnan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A265 - A265
  • [33] Treatment of Paclitaxel-Eluting Stent Restenosis With Sirolimus-Eluting Stent Implantation - Angiographic and Clinical Outcomes
    Byrne, Robert
    Iijima, Raisuke
    Mehilli, Julinda
    Pache, Juergen
    Schulz, Stefanie
    Schoemig, Albert
    Kastrati, Adnan
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (11): : 1134 - 1139
  • [34] Efficacy of Paclitaxel-eluting Balloon Catheter in Patients with Recurrences after Drug-eluting Stent Implantation for In-stent Restenosis
    Habara, Seiji
    Kadota, Kazushige
    Ichinohe, Tahei
    Ozaki, Masatomo
    Kubo, Shunsuke
    Hyodo, Yusuke
    Miyake, Koshi
    Saito, Naoki
    Otsuru, Suguru
    Otsuji, Hideaki
    Hasegawa, Daiji
    Shigemoto, Yoshikazu
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B171 - B171
  • [35] A serial ultrasound assessment of neoaneurysm following paclitaxel-eluting stent implantation
    Park, Chan Seok
    Kim, Pum-Joon
    Park, Hun-Jun
    Jang, Seong-Won
    Jung, Hae-Ok
    Kim, Hee Yeol
    Baek, Sang-Hong
    Seung, Ki-Bae
    Choi, Kyu-Bo
    Lee, Dong Hoon
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 123 (01) : E21 - E22
  • [36] "Very" Very Late Stent Thrombosis: The Occurrence of Thrombosis 12.3 Years After Paclitaxel-Eluting Stent Implantation
    Tran, Hung D.
    Pham, Ha V. T.
    Vu, Thang D.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [37] Relationship between renal function stage and clinical outcomes after paclitaxel-eluting stent implantation
    Yazaki, Yoshiyuki
    Iijima, Raisuke
    Nakamura, Masato
    Sugi, Kaoru
    JOURNAL OF CARDIOLOGY, 2011, 57 (01) : 61 - 68
  • [38] Appearance of thrombus formation and yellow plaque in proximal and distal stent segment after paclitaxel-eluting stent implantation
    Kakefuda, Y.
    Sato, A.
    Adachi, T.
    Watabe, H.
    Ojima, E.
    Naruse, Y.
    Hoshi, T.
    Murakoshi, N.
    Aonuma, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 865 - 865
  • [39] Serial changes of coronary endothelial function and arterial healing after paclitaxel-eluting stent implantation
    Mitsutake Y.
    Ueno T.
    Ikeno F.
    Yokoyama S.
    Sasaki K.-I.
    Nakayoshi T.
    Itaya N.
    Chibana H.
    Sasaki M.
    Fukumoto Y.
    Cardiovascular Intervention and Therapeutics, 2016, 31 (1) : 21 - 28
  • [40] Damage to Polymer of Paclitaxel-Eluting Stent
    Kitahara, Hideki
    Kobayashi, Yoshio
    Yamaguchi, Masashi
    Ohkubo, Kenji
    Nakayama, Takashi
    Kuroda, Nakabumi
    Komuro, Issei
    CIRCULATION JOURNAL, 2008, 72 (11) : 1907 - 1908