Aorto-oesophageal fistula after corrosive ingestion: A case report

被引:0
|
作者
Scriba, Matthias Frank [1 ,4 ]
Kotze, Urda [2 ]
Naidoo, Nadraj [3 ]
Jonas, Eduard [1 ]
Chinnery, Galya Eileen [1 ]
机构
[1] Univ Cape Town, Groote Schuur Hosp, Dept Surg, Surg Gastroenterol Unit, ZA-7925 Cape Town, Western Cape, South Africa
[2] Univ Cape Town, Fac Hlth Sci, Dept Surg, Surg Gastroenterol Unit, ZA-7925 Cape Town, Western Cape, South Africa
[3] Univ Cape Town, Groote Schuur Hosp, Dept Surg, Vasc & Endovascular Surg Unit, ZA-7925 Cape Town, Western Cape, South Africa
[4] Univ Cape Town, Groote Schuur Hosp, Dept Surg, Surg Gastroenterol, Anzio Rd, ZA-7925 Cape Town, Western Cape, South Africa
来源
关键词
Aorto-oesophageal fistula; Corrosive/caustic injury; Corrosive ingestion; Case report; TRACHEOESOPHAGEAL;
D O I
10.4240/wjgs.v14.i5.506
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND Aorto-oesophageal fistula (AOF) are uncommon and exceedingly rare after corrosive ingestion. The authors report a case of AOF after corrosive ingestion that survived. A comprehensive literature review was performed to identify all cases of AOF after corrosive ingestion to determine the incidence of this condition, how it is best managed and what the outcomes are. CASE SUMMARY A previously healthy 30-year-old male, presented with a corrosive oesophageal injury after drain cleaner ingestion. He did not require acute surgical resection, but developed long-segment oesophageal stricturing, which was initially managed with cautious dilatation and later stenting. An AOF was suspected at endoscopy performed two months after the ingestion, when the patient represented with massive upper gastrointestinal bleeding. The fistula was confirmed on computerised tomographic angiography. The initial bleeding at endoscopy was temporised by oesophageal stenting; a second stent was placed when bleeding recurred later the same day. The stenting successfully achieved temporary bleeding control, but resulted in sudden respiratory distress, which was found to be due to left main bronchus compression caused by the overlapping oesophageal stents. Definitive bleeding control was achieved by endovascular aortic stent-grafting. A retrosternal gastroplasty was subsequently performed to achieve gastrointestinal diversion to reduce the risk of stent-graft sepsis. He was subsequently successfully discharged and remains well one year post injury. CONCLUSION AOF after corrosive ingestion is exceedingly rare, with a very high mortality. Most occur weeks to months after the initial corrosive ingestion. Conservative management is ill-advised.
引用
收藏
页码:506 / 513
页数:8
相关论文
共 50 条
  • [31] Aorto-Oesophageal Fistula in Patient With Montgomery Salivary Bypass Tube
    Blanco Perez, Pedro
    Batuecas Caletrio, Angel
    Munoz Herrera, Angel
    Cruz Ruiz, Santiago Santa
    ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2008, 59 (01): : 39 - 40
  • [32] Aorto-oesophageal fistula after oesophageal stent placement in a patient with a Roux-en-Y gastric bypass
    Boerlage, T. C. C.
    Hermanides, H. S.
    Moes, D. E.
    Tan, I. L.
    Houben, G. M. P.
    Acherman, Y. I. Z.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2016, 98 (08) : E178 - E180
  • [33] Aorto-oesophageal fistula with upper gastrointestinal tract intramural haematoma in an oesophageal cancer patient
    Hsieh, Min-Shiau
    Hsu, Po-Kuei
    Chen, Po-Lin
    Hsu, Wen-Hu
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 45 (03) : 584 - 584
  • [34] Aorto-oesophageal fistula and aortic pseudoaneurysm caused by a swallowed fish bone
    Sia, K. J.
    Ashok, G. D.
    Ahmad, F. M. A.
    Kong, Catherine K. L.
    HONG KONG MEDICAL JOURNAL, 2013, 19 (06) : 542 - 544
  • [35] An aorto-oesophageal fistula following endograft: sealing of fistulae with omentum and replacement of the aorta
    Idhrees, A. Mohammed
    Jacob, Aju
    Velayudhan, Bashi V.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2018, 26 (03) : 516 - 518
  • [36] Delayed presentation of a traumatic descending thoracic aorta aneurysm as an aorto-oesophageal fistula
    Mohamed, Saifullah
    Patel, Akshay J.
    Iqbal, Yassir H.
    Ranasinghe, Aaron
    JOURNAL OF SURGICAL CASE REPORTS, 2020, (07):
  • [37] Vascular ring connector-related aorto-oesophageal fistula of the descending aorta
    Chen, Hsi-Chih
    Wu, Yu-Cheng
    Lin, Yi-Chang
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 61 (01) : 238 - 238
  • [38] Aorto-oesophageal Fistula from Miliary Tuberculosis: A Rare Cause of Massive Haematemesis
    Yeow, Yuyi
    Fong, Sau Shung
    Rao, Jaideepraj
    Sim, Richard
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2014, 43 (11) : 559 - 560
  • [39] Lethal aorto-oesophageal fistula 16 years after aortic prosthetic reconstruction: Delayed rupture as cause of death
    Benedetti, Beatrice
    Felice, Marica
    Locco, Francesco
    Roberti, Paola
    Demontis, Roberto
    MEDICINE SCIENCE AND THE LAW, 2021, 61 (1_SUPPL) : 146 - 149
  • [40] Spiral computed tomography demonstration of aorto-oesophageal fistula from fish-bone
    Lim, CCT
    Cheah, FK
    Tan, JCH
    CLINICAL RADIOLOGY, 2000, 55 (12) : 976 - 977