Preliminary results of bedside inferior vena cava filter placement - Safe and cost-effective

被引:18
|
作者
Sing, RF [1 ]
Smith, CH [1 ]
Miles, WS [1 ]
Messick, WJ [1 ]
机构
[1] Carolinas Med Ctr, Dept Surg, Charlotte, NC 28203 USA
关键词
cost-effective; thromboembolism; vena cava filter;
D O I
10.1378/chest.114.1.315
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The use of inferior vena cava filters (IVCFs) is increasing in patients at high risk for venous thromboembolism; however, there is considerable controversy related to their cost. We inserted eight percutaneous IVCFs at the bedside. The hospital charges for bedside IVCF insertion were substantially lower compared with those for IVCF insertion performed in the Radiology Department or operating room. There was one death (unrelated to the procedure) and one asymptomatic caval occlusion believed to be caused by thrombus trapping. Bedside IVCF insertion is safe and cost-effective in selected patients This practice averts the potential complications associated with transporting critically ill patients.
引用
收藏
页码:315 / 316
页数:2
相关论文
共 50 条
  • [1] Bedside inferior vena cava filter (IVCF) placement in the ICU: Safe and effective pulmonary embolism (PE) prophylaxis
    Sing, R
    Cicci, C
    Messick, WJ
    CRITICAL CARE MEDICINE, 1999, 27 (01) : A164 - A164
  • [2] Bedside inferior vena cava filter placement by intravascular ultrasound in critically ill patients is safe and effective for an extended time
    Glocker, Roan J.
    Awonuga, Oluwafunmi
    Novak, Zdenek
    Pearce, Benjamin J.
    Patterson, Mark
    Matthews, Thomas C.
    Jordan, William D.
    Passman, Marc A.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2014, 2 (04) : 377 - 382
  • [3] Bedside inferior vena cava filter placement by intravascular ultrasound in critically ill patients is safe and effective for an extended time DISCUSSION
    Greenfield, Lazar J., Sr.
    Glocker, Roan J.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2014, 2 (04) : 382 - 382
  • [4] Inferior vena cava filter placement: Preinsertion inferior vena cava imaging
    Matthews, BD
    Joels, CS
    LeQuire, MH
    AMERICAN SURGEON, 2003, 69 (08) : 649 - 653
  • [5] DM inferior vena cava filter: Preliminary clinical results
    Dibie, A
    Musset, D
    Maitre, S
    Parent, F
    Girard, P
    Laborde, F
    Simonneau, G
    CIRCULATION, 1996, 94 (08) : 1749 - 1749
  • [6] Bedside carbon dioxide cavagrams for inferior vena cava filters: Preliminary results
    Sing, RF
    Cicci, CK
    LeQuire, MH
    Stackhouse, DJ
    JOURNAL OF VASCULAR SURGERY, 2000, 32 (01) : 144 - 147
  • [7] Safety and Effectiveness of the Celect Inferior Vena Cava Filter: Preliminary Results
    Sangwaiya, Minal Jagtiani
    Marentis, Theodore C.
    Walker, T. Gregory
    Stecker, Michael
    Wicky, Stephan T.
    Kalva, Sanjeeva P.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (09) : 1188 - 1192
  • [8] Transabdominal Duplex Ultrasonography for Bedside Inferior Vena Cava Filter Placement: Examples, Technique, and Review
    Amankwah, Kwame S.
    Seymour, Keri
    Costanza, Michael
    Berger, Jeremy
    Gahtan, Vivian
    VASCULAR AND ENDOVASCULAR SURGERY, 2009, 43 (04) : 379 - 384
  • [9] Indications and Appropriateness of Inferior Vena Cava Filter Placement
    Patel, Gaurav
    Panikkath, Ragesh
    Fenire, Mahmoud
    Gadwala, Swetha
    Nugent, Kenneth
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2015, 349 (03): : 212 - 216
  • [10] Re: Filter placement in double inferior vena cava
    Sugimoto, K
    Imanaka, K
    Kawabe, T
    Hirota, S
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (01) : 79 - 80