Safety and Effectiveness of the Celect Inferior Vena Cava Filter: Preliminary Results

被引:39
|
作者
Sangwaiya, Minal Jagtiani [1 ]
Marentis, Theodore C.
Walker, T. Gregory [1 ]
Stecker, Michael [2 ]
Wicky, Stephan T. [1 ]
Kalva, Sanjeeva P. [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
关键词
CLINICAL-EXPERIENCE; PULMONARY-EMBOLISM; FOLLOW-UP; RETRIEVAL; PENETRATION; PROTECTION; TEMPORARY; OUTCOMES;
D O I
10.1016/j.jvir.2009.05.033
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the safety and effectiveness of the Celect inferior vena cava (IVC) filter during implantation, retrieval, and short-term follow-up. MATERIALS AND METHODS: The clinical data of 73 patients (46 men; age range, 22-89 years) who had a Celect IVC filter implanted between August 2007 and June 2008 were reviewed. Twenty-one (28.8%) presented with pulmonary embolism (PE), 15 (20.54%) with deep vein thrombosis (DVT), 12 (16.4%) with both, and the rest (34.26%) with other symptoms. Indications for filter placement were contraindication to anticoagulation (n = 38; 52%), prophylaxis/added protection (n = 22; 30%), failure of anticoagulation (n = 11; 15%), and complications of anticoagulation (n = 2; 3%). Filters were placed in the infrarenal (n = 71) or suprarenal (n = 2) IVC. Follow-up data were reviewed for filter-related complications and recurrent PE. RESULTS: All filters were successfully deployed. Immediately after fluoroscopy-guided filter deployment in 61 patients, four filters (6.5%) showed significant tilt. During follow-up (mean, 68 days +/- 73), three patients developed symptoms of PE after filter placement; however, computed tomographic (CT) pulmonary angiography demonstrated new PE in only two. Imaging follow-up with radiography (n = 32), CT (n = 11), and/or angiography (n = 4) in 47 patients (at a mean of 62 days +/- 75) showed no filter migration. Follow-up abdominal CT (at a mean of 69 days +/- 58) was available in 18 patients and demonstrated filter-related problems in seven (39%). These included penetration of filter legs in four and fracture/migration of filter components in one. Fourteen filters were successfully retrieved after a median period of 84 days. CONCLUSIONS: The Celect IVC filter can be safely placed but is related to a high incidence of caval filter leg penetration. Symptomatic PE after filter placement confirmed by CT occurred in 2.8% of patients.
引用
收藏
页码:1188 / 1192
页数:5
相关论文
共 50 条
  • [1] Symptomatic caval penetration by a Celect inferior vena cava filter
    Conor O. Bogue
    Philip R. John
    Bairbre L. Connolly
    David J. Rea
    Joao G. Amaral
    Pediatric Radiology, 2009, 39 : 1110 - 1113
  • [2] Symptomatic caval penetration by a Celect inferior vena cava filter
    Bogue, Conor O.
    John, Philip R.
    Connolly, Bairbre L.
    Rea, David J.
    Amaral, Joao G.
    PEDIATRIC RADIOLOGY, 2009, 39 (10) : 1110 - 1113
  • [3] DM inferior vena cava filter: Preliminary clinical results
    Dibie, A
    Musset, D
    Maitre, S
    Parent, F
    Girard, P
    Laborde, F
    Simonneau, G
    CIRCULATION, 1996, 94 (08) : 1749 - 1749
  • [4] Significant caval penetration by the Celect inferior vena cava filter: Attributable to filter design?
    Sadaf, Arifa
    Rasuli, Pasteur
    Olivier, Andre
    Hadziomerovic, Adnan
    French, Gordon J.
    Aquino, Jose
    O'Kelly, Kevin
    Al-Mutairi, Badr
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (11) : 1447 - 1450
  • [5] Safety and Effectiveness of the Denali Inferior Vena Cava Filter: Intermediate Follow-Up Results
    Reis, Stephen P.
    Kovoor, Jerry
    Sutphin, Patrick D.
    Toomay, Seth
    Trimmer, Clayton
    Pillai, Anil
    Reddick, Mark
    Kalva, Sanjeeva P.
    VASCULAR AND ENDOVASCULAR SURGERY, 2016, 50 (06) : 385 - 390
  • [6] Perforation of Inferior Vena Cava by Inferior Vena Cava Filter
    Unterman, Sarah
    Nair, Tad
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2013, 14 (02) : 161 - 162
  • [7] Preliminary Experience With Option Inferior Vena Cava Filter
    Iqbal, Shams I.
    Elmi, Azadeh
    Hedgire, Sandeep
    Yeddula, Kalpana
    Ganguli, Suvranu
    Walker, T. Gregory
    Salazar, Gloria M.
    Wicky, Stephan
    Kalva, Sanjeeva P.
    VASCULAR AND ENDOVASCULAR SURGERY, 2013, 47 (01) : 24 - 29
  • [8] Retrospective Review of 120 Celect Inferior Vena Cava Filter Retrievals: Experience at a Single Institution
    Zhou, Dayong
    Spain, James
    Moon, Eunice
    Mclennan, Gordon
    Sands, Mark J.
    Wang, Weiping
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (12) : 1557 - 1563
  • [9] The DM (Dibie-Musset) inferior vena cava filter: Preliminary clinical results
    Musset, D
    Dibie, A
    Maitre, S
    Parent, F
    Girard, P
    Simonneau, G
    RADIOLOGY, 1997, 205 : 1028 - 1028
  • [10] Byrd sheaths for complex inferior vena cava filter retrieval: Results of a preliminary study
    Szmygin, Maciej
    Goralczyk, Wanesa
    Wach, Damian
    Jargiello, Tomasz
    Pyra, Krzysztof
    KARDIOLOGIA POLSKA, 2023, 81 (04) : 390 - 392