Frequency Doubling Technology perimetry and standard automated perimetry in migraine

被引:18
|
作者
Harle, DE
Evans, BJW
机构
[1] Inst Optometry, Neville Chappell Res Clin, London SE1 6DS, England
[2] City Univ London, Dept Optometry & Visual Sci, London, England
关键词
glaucoma; migraine; vision; visual fields;
D O I
10.1111/j.1475-1313.2005.00285.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The literature suggests that visual field defects may be more common in people who experience migraine. The Humphrey frequency doubling (FDT) visual field instrument selectively examines the magnocellular visual pathway, but has not previously been used to investigate visual function in migraine. In a masked controlled study we compared Humphrey FDT and Humphrey Swedish Interactive Threshold Algorithm fields of 25 migraine sufferers with 25 age- and gender-matched controls. Although both mean deviation and pattern standard deviation were a little worse in the migraine group, these differences did not reach statistical significance. There were no inter-eye visual field differences in the migraine group compared with controls. Comparing the mean of all the contrast thresholds in each hemisphere, there were no more inter-hemifield visual field differences in the migraine group compared with controls. There was no significant difference between the migraine and control groups in intra-ocular pressures. The visual field parameters were not correlated with the interval since the last migraine headache, the severity of migraine headache, the duration of migraine headache or the number of migraine headaches per annum. In our data, there was no evidence of visual field deficits, a magnocellular deficit, or indications of glaucomatous pathology.
引用
下载
收藏
页码:233 / 239
页数:7
相关论文
共 50 条
  • [41] Association between frequency doubling perimetry (FDP) and standard automated perimetry: The Los Angeles Latina Eye Study (LALES)
    Tong, LT
    Ying-Lai, M
    Francis, B
    Varma, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [42] Frequency doubling perimetry and short-wavelength automated perimetry to detect early glaucoma
    Leeprechanon, Narakorn
    Giaconi, Joann A.
    Manassakorn, Anita
    Hoffman, Douglas
    Caprioli, Joseph
    OPHTHALMOLOGY, 2007, 114 (05) : 931 - 937
  • [43] Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children
    Kocabeyoglu, Sibel
    Uzun, Salih
    Mocan, Mehmet Cem
    Bozkurt, Banu
    Irkec, Murat
    Orhan, Mehmet
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (10) : 576 - 579
  • [44] Selective Perimetry: Comparing Heidelberg Edge Perimetry and Frequency-Doubling Technology Perimetry in Detecting Glaucomatous Loss
    Fingeret, M.
    Klein, R.
    Sloane, A.
    Canellos, E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [45] Comparison of conventional automated perimetry, short-wavelength automated perimetry and frequency-doubling technology in the assessment of patients with multiple sclerosis
    Corallo, G
    Capris, P
    Barabino, S
    Cicinelli, S
    Mastromarino, A
    Bandini, F
    Uccelli, A
    Solaro, C
    Zanardi, S
    Calabria, G
    PERIMETRY UPDATE 2002/2003, 2004, : 97 - 101
  • [46] Glaucomatous visual field progression with frequency-doubling technology and standard automated perimetry in a longitudinal prospective study
    Haymes, SA
    Hutchison, DM
    McCormick, TA
    Varma, DK
    Nicolela, MT
    LeBlanc, RP
    Chauhan, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (02) : 547 - 554
  • [47] Effect of cataract extraction on frequency doubling technology perimetry
    Kook, MS
    Yang, SJ
    Kim, S
    Chung, J
    Kim, ST
    Tchah, H
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (01) : 85 - 90
  • [48] Frequency-doubling technology perimetry and optical defocus
    Anderson, AJ
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (09) : 4147 - 4152
  • [49] Screening with frequency doubling technology perimetry in a metropolitan community
    Mansberger, SL
    Johnson, CA
    Butler, WA
    Cioffi, GA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U244 - U244
  • [50] Frequency doubling technology perimetry in rhegmatogenous retinal detachment
    Chou, LC
    Sheu, SJ
    Chen, YY
    Chen, JF
    Wu, TT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U138 - U138