A computer-controlled current-comparator-based four-terminal resistance bridge for power frequencies

被引:6
|
作者
So, E [1 ]
Djokic, B [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
关键词
bridge circuits; current comparators; resistance measurements;
D O I
10.1109/19.918119
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A current comparator technique is applied to four-terminal resistance measurements for obtaining a highly accurate ac resistance bridge at, power frequencies of 50 to 60 Hz, Active circuits are used to establish equal voltage drops between the potential terminals of the two resistances being compared. The bridge is suitable for measuring resistances from 10 mu Omega to 100 k Omega. A cascading technique using two two-stage current transformers provides extension of the ratio range to 100 000 000 with a maximum applied current of 10 000 A. The bridge features measurement with a resolution of one part in 10(7), The total combined uncertainty (2 sigma) of the bridge, including the range extenders at power frequencies, is estimated to be less than 5 mu Omega/Omega.
引用
收藏
页码:272 / 274
页数:3
相关论文
共 45 条
  • [21] A portable current-comparator-based system for on-site calibrations of low-power-factor wattmeters
    So, Eddy
    Djokic, Branislav
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (02) : 581 - 583
  • [22] A DIRECT-CURRENT-COMPARATOR RATIO BRIDGE FOR 4-TERMINAL RESISTANCE MEASUREMENTS
    MACMARTIN, MP
    KUSTERS, NL
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1966, IM15 (04) : 212 - +
  • [23] Quantum Hall Resistance verification based on a Direct Current Comparator Bridge
    Pollarolo, Alessio
    Brown, Duane
    Huang, Shiping
    Wachowicz, Andrew
    Brown, Ryan
    [J]. 2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [24] A MODIFIED TECHNIQUE FOR THE CALIBRATION OF A CURRENT-COMPARATOR-BASED HIGH VOLTAGE CAPACITANCE BRIDGE AND ITS COMPARISON BETWEEN KRISS AND NRC
    Faisal, Agah
    Jung, Jae Kap
    So, Eddy
    [J]. 2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 671 - +
  • [25] A STABLE AND ACCURATE CURRENT COMPARATOR-BASED QUADRATURE CURRENT REFERENCE FOR POWER FREQUENCIES
    SO, E
    MOORE, WJM
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1982, 31 (01) : 43 - 46
  • [26] A RESISTANCE RATIO BRIDGE BASED ON A CRYOGENIC CURRENT COMPARATOR FOR MEASURING THE QUANTIZED HALL RESISTANCE
    VANDERWEL, W
    MOOIJ, JE
    HARMANS, CJPM
    ANDRE, JP
    WEIMANN, G
    PLOOG, K
    FOXON, CT
    HARRIS, JJ
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1989, 38 (01) : 54 - 58
  • [27] A DIRECT-READING CURRENT-COMPARATOR BRIDGE FOR SCALING 4-TERMINAL IMPEDANCES AT AUDIO FREQUENCIES
    MOORE, WJM
    BASU, SK
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1966, IM15 (04) : 253 - &
  • [28] AC Quantum Hall Resistance combined with a Four-Terminal Pair Pulse-Driven Josephson Impedance Bridge
    Bauer, S.
    Pimsut, Y.
    Behr, R.
    Kieler, O.
    Kruskopf, M.
    Palafox, L.
    Lee, J.
    Schurr, J.
    [J]. 2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [29] NEW CRYOGENIC CURRENT COMPARATOR- BASED RESISTANCE COMPARISON BRIDGE AT LNE
    Soukiassian, L.
    Spengler, G.
    Leprat, D.
    Schopfer, F.
    Poirier, W.
    [J]. 2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 761 - 762
  • [30] Waveform generator based on computer-controlled switching power suplies.
    Jimenez, G
    Sevillano, JL
    Diaz, F
    Linares, A
    Rodríguez, MA
    [J]. IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 627 - 632