A computer-controlled current-comparator-based four-terminal resistance bridge for power frequencies

被引:6
|
作者
So, E [1 ]
Djokic, B [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
关键词
bridge circuits; current comparators; resistance measurements;
D O I
10.1109/19.918119
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A current comparator technique is applied to four-terminal resistance measurements for obtaining a highly accurate ac resistance bridge at, power frequencies of 50 to 60 Hz, Active circuits are used to establish equal voltage drops between the potential terminals of the two resistances being compared. The bridge is suitable for measuring resistances from 10 mu Omega to 100 k Omega. A cascading technique using two two-stage current transformers provides extension of the ratio range to 100 000 000 with a maximum applied current of 10 000 A. The bridge features measurement with a resolution of one part in 10(7), The total combined uncertainty (2 sigma) of the bridge, including the range extenders at power frequencies, is estimated to be less than 5 mu Omega/Omega.
引用
收藏
页码:272 / 274
页数:3
相关论文
共 45 条
  • [1] A power-frequency current-comparator-based direct-reading four-terminal resistance bridge
    So, E
    Djokic, B
    [J]. 2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 178 - 179
  • [2] A Current Comparator Based Four-terminal Impedance Bridge
    Wang, Yunjing
    Qu, Zhengwei
    Hu, Xiaochuan
    [J]. INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 752 - 757
  • [3] A Synchronized Current-Comparator-Based Power Bridge for Calibrating Analog Merging Units
    Djokic, Branislav
    Parks, Harold
    [J]. 2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [4] A MICROPROCESSOR-CONTROLLED HIGH-VOLTAGE CURRENT-COMPARATOR-BASED CAPACITANCE BRIDGE
    SO, E
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (02) : 533 - 537
  • [5] A current-comparator-based bridge for calibrating power and energy standards at 50/60 Hz
    Kyriazis, GA
    Oldham, NM
    Werneck, M
    [J]. 2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 256 - 257
  • [6] A current-comparator-based high-voltage inductance bridge
    So, E.
    [J]. 2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 710 - 711
  • [7] Quasi-Balance Four-Terminal Resistance Bridge
    Lai, Lei
    Feng, Jian
    Shi, Leibing
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (06) : 1636 - 1641
  • [8] An AC Four-Terminal Low Value Resistance Bridge
    Huang, Xiaoding
    Zhang, Xin
    Tong, Yazhen
    Cai, Jianzhen
    [J]. 2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [9] A Modified Technique for Calibration of Current-Comparator-Based Capacitance Bridge and Its Verification
    Faisal, Agah
    Jung, Jae Kap
    So, Eddy
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (07) : 2642 - 2647