A deep-learning reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography

被引:26
|
作者
Wang, Mengzhen [1 ]
Fan, Jing [1 ]
Shi, Xiaofeng [1 ]
Qin, Le [1 ]
Yan, Fuhua [1 ]
Yang, Wenjie [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Radiol, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Coronary computed tomography angiography; Deep learning; Low tube voltage; Image reconstruction; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; NOISE-REDUCTION; ABDOMINAL CT; MULTICENTER;
D O I
10.1016/j.ejrad.2021.110070
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the image quality (IQ) of low tube voltage coronary CT angiography (CCTA) images reconstructed with deep learning image reconstruction (DLIR). Methods: According to body mass index (BMI), eighty patients who underwent 70kVp CCTA (Group A, N = 40, BMI <= 26 kg/m2) or 80kVp CCTA (Group B, N = 40, BMI > 26 kg/m2) were prospectively included. All images were reconstructed with four algorithms, including filtered back-projection (FBP), adaptive statistical iterative reconstruction-Veo at a level of 50% (ASiR-V50%), and DLIR at medium (DLIR-M) and high (DLIR-H) levels. Image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and edge rise distance (ERD) within aorta root and coronary arteries were calculated. The IQ was subjectively evaluated by using a 5-point scale. Results: Compared with FBP, ASiR-V50% and DLIR-M, DLIR-H led to the lowest noise (Group A: 24.7 +/- 5.0HU; Group B, 21.6 +/- 2.8 HU), highest SNR (Group A, 24.9 +/- 5.0; Group B, 28.0 +/- 5.8), CNR (Group A, 42.2 +/- 15.2; Group B, 43.6 +/- 10.5) and lowest ERD (Group A, 1.49 +/- 0.30 mm; Group B, 1.50 +/- 0.22 mm) with statistical significance (all P < 0.05). For the objective assessment, the percentages of 4 and 5 IQ scores were significantly higher for DLIR-H (Group A, 93.8%; Group B,90.0%) and DLIR-M (Group A, 85.6%; Group B,86.9 %) compared to ASiR-V50% (Group A, 58.8%; Group B, 58.8%) and FBP (Group A, 34.4%; Group B, 33.1%) algorithms (all P < 0.05). Conclusion: The application of DLIR significantly improves both objective and subjective IQ in low tube voltage CCTA compared with ASiR-V and FBP, which may promote a further radiation dose reduction in CCTA.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction
    Otgonbaatar, Chuluunbaatar
    Ryu, Jae-Kyun
    Shin, Jaemin
    Woo, Ji Young
    Seo, Jung Wook
    Shim, Hackjoon
    Hwang, Dae Hyun
    KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (11) : 1044 - 1054
  • [32] Improving image quality with super-resolution deep-learning-based reconstruction in coronary CT angiography
    Yasunori Nagayama
    Takafumi Emoto
    Yuki Kato
    Masafumi Kidoh
    Seitaro Oda
    Daisuke Sakabe
    Yoshinori Funama
    Takeshi Nakaura
    Hidetaka Hayashi
    Sentaro Takada
    Ryutaro Uchimura
    Masahiro Hatemura
    Kenichi Tsujita
    Toshinori Hirai
    European Radiology, 2023, 33 : 8488 - 8500
  • [33] Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography
    Wang, Xinrui
    Zhu, Chengcheng
    Li, Jing
    Degnan, Andrew J.
    Jiang, Tao
    Lu, Jianping
    MEDICINE, 2018, 97 (30)
  • [34] Deep-learning image-reconstruction algorithm for dual-energy CT angiography with reduced iodine dose: preliminary results
    Noda, Y.
    Nakamura, F.
    Kawamura, T.
    Kawai, N.
    Kaga, T.
    Miyoshi, T.
    Kato, H.
    Hyodo, F.
    Matsuo, M.
    CLINICAL RADIOLOGY, 2022, 77 (02) : E138 - E146
  • [35] Image Quality and Radiation Exposure With a Low Tube Voltage Protocol for Coronary CT Angiography Results of the PROTECTION II Trial
    Hausleiter, Jorg
    Martinoff, Stefan
    Hadamitzky, Martin
    Martuscelli, Eugenio
    Pschierer, Iris
    Feuchtner, Gudrun M.
    Catalan-Sanz, Paz
    Czermak, Benedikt
    Meyer, Tanja S.
    Hein, Franziska
    Bischoff, Bernhard
    Kuse, Miriam
    Schomig, Albert
    Achenbach, Stephan
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (11) : 1113 - 1123
  • [36] Deep Learning-Based Reconstruction Improves the Image Quality of Low-Dose CT Colonography
    Chen, Yanshan
    Huang, Zixuan
    Feng, Lijuan
    Zou, Wenbin
    Kong, Decan
    Zhu, Dongyun
    Dai, Guochao
    Zhao, Weidong
    Zhang, Yuanke
    Luo, Mingyue
    ACADEMIC RADIOLOGY, 2024, 31 (08) : 3191 - 3199
  • [37] Tube Voltage, DNA Double-Strand Breaks, and Image Quality in Coronary CT Angiography
    Lin, Zhu Xiao
    Zhou, Fan
    Schoepf, U. Joseph
    Pillai, Balakrishnan
    Zhou, Chang Sheng
    Quan, Wei
    Bao, Xue Qin
    Lu, Guang Ming
    Zhang, Long Jiang
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (08) : 967 - 977
  • [38] Assessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies
    Jeon, Pil-Hyun
    Jeon, Sang-Hyun
    Ko, Donghee
    An, Giyong
    Shim, Hackjoon
    Otgonbaatar, Chuluunbaatar
    Son, Kihong
    Kim, Daehong
    Ko, Sung Min
    Chung, Myung-Ae
    DIAGNOSTICS, 2023, 13 (11)
  • [39] Ultralow dose coronary calcium scoring CT at reduced tube voltage and current by using deep learning image reconstruction
    Zhuo, Liyong
    Xu, Shijie
    Zhang, Guozhi
    Xing, Lihong
    Zhang, Yu
    Ma, Zepeng
    Wang, Jianing
    Yin, Xiaoping
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [40] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Caruso, Damiano
    De Santis, Domenico
    Del Gaudio, Antonella
    Guido, Gisella
    Zerunian, Marta
    Polici, Michela
    Valanzuolo, Daniela
    Pugliese, Dominga
    Persechino, Raffaello
    Cremona, Antonio
    Barbato, Luca
    Caloisi, Andrea
    Iannicelli, Elsa
    Laghi, Andrea
    EUROPEAN RADIOLOGY, 2024, 34 (04) : 2384 - 2393