Simultaneous kinetic spectrophotometric determination of sulfide and sulfite ions by using an optode and the partial least squares (PLS) regression

被引:16
|
作者
Sarlak, Nahid [1 ]
Anizadeh, Masoumeh [1 ]
机构
[1] Lorestan Univ, Dept Chem, Fac Sci, Khorramabad, Iran
关键词
Optode; Partial least squares (PLS); Crystal violet; Sulfite; Sulfide; BISULFITE ADDITION-REACTION; FLOW-INJECTION ANALYSIS; METHYLENE-BLUE; TRACE AMOUNTS; SENSOR; MEMBRANES; IMMOBILIZATION; THIOSULFATE;
D O I
10.1016/j.snb.2011.08.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The characterization of an optical sensor membrane is described for simultaneous determination of sulfite and sulfide ions based on the immobilization of crystal violet on a triacetylcellulose membrane. The absorbance of the membranes decreased by increasing sulfite and sulfide concentration. The partial least squares (PLS-1) calibration model based on spectrophotometric measurement for simultaneous determination of sulfite and sulfide ions was applied. This method is based on the difference between the rate of the reaction of sulfide and sulfite with membranes in pH 7.0 buffer solution and at 25 degrees C. The experimental calibration matrix for partial least squares (PLS-1) calibration was designed with 18 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range of 200-2000 mu g mL(-1) (2.5-25 mmol L(-1)) and 80-900 mu g mL(-1) (2.5-28.125 mmol L(-1)) for sulfite and sulfide, respectively. The sensor can readily be regenerated with water and the color is fully reversible. The sensor was successfully applied to the simultaneous determination of sulfide and sulfite in water samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:644 / 649
页数:6
相关论文
共 50 条
  • [1] Simultaneous kinetic spectrophotometric determination of sulfite and sulfide using partial least squares (PLS) regression
    Afkhami, Abbas
    Sarlak, Nahid
    Zarei, Ali Reza
    Madrakian, Tayyebeh
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2006, 27 (06) : 863 - 868
  • [2] Simultaneous kinetic spectrophotometric determination of cyanide and thiocyanate using the partial least squares (PLS) regression
    Afkhami, Abbas
    Sarlak, Nahid
    Zarei, Ali Reza
    TALANTA, 2007, 71 (02) : 893 - 899
  • [3] Simultaneous kinetic-spectrophotometric determination of sulfide and sulfite by partial least squares and genetic algorithm variable selection
    J. Ghasemi
    D. M. Ebrahimi
    L. Hejazi
    R. Leardi
    A. Niazi
    Journal of Analytical Chemistry, 2007, 62 : 348 - 354
  • [4] Simultaneous kinetic-spectrophotometric determination of sulfide and sulfite by partial least squares and genetic algorithm variable selection
    Ghasemi, J.
    Ebrahimi, D. M.
    Hejazi, L.
    Leardi, R.
    Niazi, A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (04) : 348 - 354
  • [5] Simultaneous kinetic-spectrophotometric determination of sulfide and sulfite and genetic algorithim variable selection using partial least squares calibration
    Ghasemi, J
    Ebrahimi, DM
    Hejazi, L
    Leardi, R
    Niazi, A
    JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (01) : 92 - 98
  • [6] Simultaneous kinetic-spectrophotometric determination of sulfide and sulfite and genetic algorithim variable selection using partial least squares calibration
    Jahanbakhsh Ghasemi
    Diako M. Ebrahimi
    Leila Hejazi
    Ricardo Leardi
    Ali Niazi
    Journal of Analytical Chemistry, 2006, 61 : 92 - 98
  • [7] Simultaneous kinetic spectrophotometric determination of Cu(II), Co(II) and Ni(II) using partial least squares (PLS) regression
    Bahram, Morteza
    Farhadi, Khalil
    Afkhami, Abbas
    Shokatynia, Donya
    Arjmand, Farzin
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2009, 7 (03): : 375 - 381
  • [8] Simultaneous kinetic spectrophotometric determination of spironolactone and canrenone in urine using partial least-squares regression
    Martín, E
    Jiménez, AI
    Hernández, O
    Jiménez, F
    Arias, JJ
    TALANTA, 1999, 49 (01) : 143 - 154
  • [9] Simultaneous spectrophotometric determination of atrazine and dicamba in water by Partial Least Squares Regression
    Amador-Hernández, J
    Valázquez-Manzanares, M
    Gutiérrez-Ortiz, MD
    Hernández-Carlos, B
    Peral-Torres, M
    López-De-Alba, PL
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2005, 50 (02): : 461 - 464
  • [10] Simultaneous spectrophotometric determination of copper(II) and zinc(II) using partial least squares regression
    Kompany-Zareh, M
    Safavi, A
    Hoseini, M
    CHEMIA ANALITYCZNA, 2004, 49 (02): : 225 - 233