A simple ICP-MS method for the determination of rhenium in seawater and its concentration in Tokyo Bay

被引:0
|
作者
Tagami, K [1 ]
Uchida, S [1 ]
机构
[1] Natl Inst Radiol Sci, Environm & Toxicol Sci Res Grp, Inage Ku, Chiba 2638555, Japan
关键词
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In order to determine Re in seawater samples by inductively coupled plasma mass spectrometry, a simple separation method has been applied. An extraction chromatographic resin (TEVA resin, Eichrom Ind. Inc.) was employed to separate Re from sample matrices and trace elements that cause isobaric interferences during ICP-MS measurements. Indeed, more than 98% of W was removed with this resin separation step; thus, there was no WH+ interference on the Re isotopes. Overall recovery of Re from seawater spiked with enriched Re-185 tracer was 96.8+/-2.9%. The instrumental detection limit by ICP-MS was 0.2 pg mL(-1); therefore, 100 ml, of seawater sample, which usually contains Re in low pg mL(-1) levels, provides good signals for an accurate determination. The Re concentration in Tokyo Bay from the surface to the bottom showed almost constant Re concentrations, with an average of 7.1 pg/g for November and 7.3 pg/g for December 2002. For the samples collected in January 2003, a different vertical distribution trend from the last two months was observed, though the values were within the reported range.
引用
收藏
页码:201 / 205
页数:5
相关论文
共 50 条
  • [41] Determination of trace metals in seawater by ICP-MS after preconcentration and matrix separation by dithiocarbamate complexes
    Satyanarayanan, M.
    Balaram, V.
    Rao, T. Gnaneshwar
    Dasaram, B.
    Ramesh, S. L.
    Mathur, Ramavati
    Drolia, R. K.
    INDIAN JOURNAL OF MARINE SCIENCES, 2007, 36 (01): : 71 - 75
  • [42] Intercomparison between FI-CL and ICP-MS for the determination of dissolved iron in Atlantic seawater
    Bowie, Andrew R.
    Ussher, Simon J.
    Landing, William M.
    Worsfold, Paul J.
    ENVIRONMENTAL CHEMISTRY, 2007, 4 (01) : 1 - 4
  • [43] Simple Determination Method Using ICP-MS for 129I in Radioactive Liquid Waste Solidified with Bitumen
    Kameo, Yutaka
    Ishimori, Ken-ichiro
    Shimada, Asako
    Takahashi, Kuniaki
    BUNSEKI KAGAKU, 2012, 61 (10) : 845 - 849
  • [44] Determination of plutonium isotopes in seawater samples by Semiconductor Alpha Spectrometry, ICP-MS and AMS techniques
    S. H. Lee
    P. P. Povinec
    J. Gastaud
    J. J. La Rosa
    E. Wyse
    L. K. Fifield
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282
  • [45] Determination of plutonium isotopes in seawater samples by Semiconductor Alpha Spectrometry, ICP-MS and AMS techniques
    Lee, S. H.
    Povinec, P. P.
    Gastaud, J.
    La Rosa, J. J.
    Wyse, E.
    Fifield, L. K.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (03) : 831 - 835
  • [46] A simple, rapid method for simultaneous determination of multiple elements in serum by using an ICP-MS equipped with collision cell
    Guofu Zhang
    Fengquan Zhang
    Wannian Liu
    Chili Liu
    Jing You
    Meichen Tian
    Tingting Cao
    Jing Jiang
    Zhongzhi Yang
    Hui Wu
    Weidong Wu
    BMC Chemistry, 17
  • [47] THE SPECIATION OF ORGANOTIN COMPOUNDS IN SEAWATER BY MICELLAR LC/ICP-MS
    SATO, K
    KOHRI, M
    OKOCHI, H
    BUNSEKI KAGAKU, 1995, 44 (07) : 561 - 568
  • [48] ANALYTICAL PROCEDURE FOR TC-99 IN SEAWATER BY ICP-MS
    MOMOSHIMA, N
    SAYAD, M
    TAKASHIMA, Y
    RADIOCHIMICA ACTA, 1993, 63 : 73 - 78
  • [49] A simple, rapid method for simultaneous determination of multiple elements in serum by using an ICP-MS equipped with collision cell
    Zhang, Guofu
    Zhang, Fengquan
    Liu, Wannian
    Liu, Chili
    You, Jing
    Tian, Meichen
    Cao, Tingting
    Jiang, Jing
    Yang, Zhongzhi
    Wu, Hui
    Wu, Weidong
    BMC CHEMISTRY, 2023, 17 (01)