Image quality evaluation of dual-layer spectral CT in comparison to single-layer CT in a reduced-dose setting

被引:16
|
作者
Thuy Duong Do [1 ]
Rheinheimer, Stephan [1 ]
Kauczor, Hans-Ulrich [1 ,2 ]
Stiller, Wolfram [1 ,2 ]
Weber, Tim [1 ]
Skornitzke, Stephan [1 ]
机构
[1] Heidelberg Univ Hosp, Clin Diagnost & Intervent Radiol DIR, Neuenheimer Feld 110, D-69120 Heidelberg, Germany
[2] German Ctr Lung Res DZL, Translat Lung Res Ctr TLRC, Heidelberg, Germany
关键词
Tomography; X-ray computed; Radiation exposure; Thorax; Abdomen; VIRTUAL MONOENERGETIC IMAGES; DETECTOR CT; ABDOMINAL CT; COMPUTED-TOMOGRAPHY; PHASE; WINDOW;
D O I
10.1007/s00330-020-06894-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To quantitatively and qualitatively evaluate image quality in dual-layer CT (DLCT) compared to single-layer CT (SLCT) in the thorax, abdomen, and pelvis in a reduced-dose setting. Methods Intraindividual, retrospective comparisons were performed in 25 patients who received at least one acquisition of all three acquisition protocols SLCTlow (100 kVp), DLCThigh (120 kVp), and DLCTlow (120 kVp), all covering the venous-phase thorax, abdomen, and pelvis with matched CTDIvol between SLCTlow and DLCTlow. Reconstruction parameters were identical between all scans. Image quality was assessed quantitatively at 10 measurement locations in the thorax, abdomen, and pelvis by two independent observers, and subjectively with an intraindividual forced choice test between the three acquisitions. Dose-length product (DLP) and CTDIvol were extracted for dose comparison. Results Despite matched CTDIvol in acquisition protocols, CTDIvol and DLP were lower for SLCTlow compared to DLCTlow and DLCThigh (DLP 408.58, 444.68, 647.08 mGy center dot cm, respectively; p < 0.0004), as automated tube current modulation for DLCTlow reached the lower limit in the thorax (mean 66.1 mAs vs limit 65 mAs). Noise and CNR were comparable between SLCTlow and DLCTlow (p values, 0.29-0.51 and 0.05-0.20), but CT numbers were significantly higher for organs and vessels in the upper abdomen for SLCTlow compared to DLCTlow. DLCThigh had significantly better image quality (Noise and CNR). Subjective image quality was superior for DLCThigh, but no difference was found between SLCTlow and DLCTlow. Conclusions DLCTlow showed comparable image quality to SLCTlow, with the additional possibility of spectral post-processing. Further dose reduction seems possible by decreasing the lower limit of the tube current for the thorax.
引用
收藏
页码:5709 / 5719
页数:11
相关论文
共 50 条
  • [21] Initial exploration of coronary stent image subtraction using dual-layer spectral CT
    Le Qin
    ShengJia Gu
    ChiHua Chen
    Huan Zhang
    ZhenBin Zhu
    XingBiao Chen
    Qun Han
    FuHua Yan
    WenJie Yang
    European Radiology, 2019, 29 : 4239 - 4248
  • [22] Comparison of Restenosis Risk in Single-Layer versus Dual-Layer Carotid Stents: A Duplex Ultrasound Evaluation
    Ján Sýkora
    Kamil Zeleňák
    Martin Vorčák
    Martin Števík
    Martina Sýkorová
    Jozef Sivák
    Marek Rovňák
    Jana Zapletalová
    Juraj Mužík
    Igor Šinák
    Egon Kurča
    Lukas Meyer
    Jens Fiehler
    CardioVascular and Interventional Radiology, 2022, 45 : 1257 - 1266
  • [23] Low Dose and Low Contrast Medium Coronary CT Angiography Using Dual-Layer Spectral Detector CT
    Yi, Yan
    Zhao, Xue-Mei
    Wu, Run-Ze
    Wang, Yun
    Vembar, Mani
    Jin, Zheng-Yu
    Wang, Yi-Ning
    INTERNATIONAL HEART JOURNAL, 2019, 60 (03) : 608 - 617
  • [24] Dual-Layer Detector Head CT to Maintain Image Quality While Reducing the Radiation Dose in Pediatric Patients
    Tan, Zhengwu
    Zhang, Lan
    Sun, Xiaojie
    Yang, Ming
    Makamure, Joyman
    Wu, Hongying
    Wang, Jing
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (10) : 1212 - 1218
  • [25] Effect of CT Acquisition Parameters on Iodine Density Measurement at Dual-Layer Spectral CT
    Kim, Hyungjin
    Park, Chang Min
    Kang, Chang Kyung
    Yoon, Jinyeong
    Chae, Kum Ju
    Goo, Jin Mo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (04) : 748 - 754
  • [26] Material separation with dual-layer CT
    Carmi, Raz
    Naveh, Galit
    Altman, Ami
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1876 - 1878
  • [27] The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media
    Huang, Xin
    Gao, Sizhe
    Ma, Yue
    Lu, Xiaomei
    Jia, Zheng
    Hou, Yang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (03) : 592 - 603
  • [28] Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality
    Kalra, MK
    Prasad, S
    Saini, S
    Blake, MA
    Varghese, J
    Halpern, EF
    Thrall, JH
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) : 1101 - 1106
  • [29] Comparison Of Dual-kVp And Dual-Layer CT In Simulations And Real CT System Measurements
    Kappler, Steffen
    Wirth, Stefan
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4101 - 4104
  • [30] The Application of Dual-layer Spectral Detector CT in Abdominal Vascular Imaging
    Lai, Lu-Yao
    Jiang, Ying
    Shu, Jian
    CURRENT MEDICAL IMAGING, 2023, 19 (14) : 1609 - 1615