Nanomanipulation of single influenza virus using dielectrophoretic concentration and optical tweezers for single virus infection to a specific cell on a microfluidic chip

被引:53
|
作者
Maruyama, Hisataka [1 ]
Kotani, Kyosuke [3 ]
Masuda, Taisuke [1 ]
Honda, Ayae [4 ]
Takahata, Tatsuro [4 ]
Arai, Fumihito [2 ,5 ]
机构
[1] Nagoya Univ, Dept Mech Sci & Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Nagoya Univ, Dept Micronano Syst Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[3] Tohoku Univ, Dept Bioengn & Robot, Aoba Ku, Sendai, Miyagi 9808579, Japan
[4] Hosei Univ, Dept Frontier Biosci, Koganei, Tokyo 1848584, Japan
[5] Japan Sci & Technol Agcy, Saitama, Japan
关键词
Nanomanipulation; Influenza virus; Dielectrophoretic force; Optical tweezers; Microfluidic chip; IN-SITU FORMATION; LASER MICROMANIPULATION; GEL MICROBEAD; MICROORGANISMS; MANIPULATION;
D O I
10.1007/s10404-010-0739-4
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A major problem when analyzing bionanoparticles such as influenza viruses (approximately 100 nm in size) is the low sample concentrations. We developed a method for manipulating a single virus that employs optical tweezers in conjunction with dielectrophoretic (DEP) concentration of viruses on a microfluidic chip. A polydimethylsiloxane microfluidic chip can be used to stably manipulate a virus. The chip has separate sample and analysis chambers to enable quantitative analysis of the virus functions before and after it has infected a target cell. The DEP force in the sample chamber concentrates the virus and prevents it from adhering to the glass substrate. The concentrated virus is transported to the sample selection section where it is trapped by optical tweezers. The trapped virus is transported to the analysis chamber and it is brought into contact with the target cell to infect it. This paper describes the DEP virus concentration for single virus infection of a specific cell. We concentrated the influenza virus using the DEP force, transported a single virus, and made it contact a specific H292 cell.
引用
收藏
页码:1109 / 1117
页数:9
相关论文
共 50 条
  • [41] Measurement of Single-Cell Deformability Using Impedance Analysis on Microfluidic Chip
    Kim, Dongil
    Choi, Eunpyo
    Choi, Sung Sik
    Lee, Sangho
    Park, Jungyul
    Yun, Kwang-Seok
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (12)
  • [42] Mechanical Characterization of a Single Yeast Cell Using a Robot Integrated Microfluidic Chip
    Chang, Di
    Sakuma, Shinya
    Uehara, Chihiro
    Uozumi, Nobuyuki
    Arai, Fumihito
    2018 INTERNATIONAL SYMPOSIUM ON MICRO-NANOMECHATRONICS AND HUMAN SCIENCE (MHS), 2018,
  • [43] Single-cell separation of cancer cells from a cell microwellarray chip using a nano tweezers
    Kajimoto, Kazuaki
    CANCER SCIENCE, 2018, 109 : 1125 - 1125
  • [44] Linking antigen specific T-cell dynamics in a microfluidic chip to single cell transcription patterns
    Ide, Hiroki
    Aoshi, Taiki
    Saito, Masato
    Espulgar, Wilfred Villariza
    Briones, Jonathan Campos
    Hosokawa, Masahito
    Matsunaga, Hiroko
    Arikawa, Koji
    Takeyama, Haruko
    Koyama, Shohei
    Takamatsu, Hyota
    Tamiya, Eiichi
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2023, 657 : 8 - 15
  • [45] Dielectrophoretic Microfluidic Chip Enables Single-Cell Measurements for Multidrug Resistance in Heterogeneous Acute Myeloid Leukemia Patient Samples
    Khamenehfar, Avid
    Gandhi, Maher K.
    Chen, Yuchun
    Hogge, Donna E.
    Li, Paul C. H.
    ANALYTICAL CHEMISTRY, 2016, 88 (11) : 5680 - 5688
  • [46] Knockdown of different influenza A virus subtypes in cell culture by a single antisense oligodeoxyribonucleotide
    Levina, Asya S.
    Repkova, Marina N.
    Mazurkova, Natalia A.
    Makarevich, Elena V.
    Ismagilov, Zinfer R.
    Zarytova, Valentina F.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2015, 46 (01) : 125 - 128
  • [47] Single-Cell Virus Sequencing of Influenza Infections That Trigger Innate Immunity
    Russell, Alistair B.
    Elshina, Elizaveta
    Kowalsky, Jacob R.
    te Velthuis, Aartjan J. W.
    Bloom, Jesse D.
    JOURNAL OF VIROLOGY, 2019, 93 (14)
  • [48] Microfluidic growth chambers with optical tweezers for full spatial single-cell control and analysis of evolving microbes
    Probst, Christopher
    Gruenberger, Alexander
    Wiechert, Wolfgang
    Kohlheyer, Dietrich
    JOURNAL OF MICROBIOLOGICAL METHODS, 2013, 95 (03) : 470 - 476
  • [49] A Novel Single Virus Infection System Reveals That Influenza Virus Preferentially Infects Cells in G1 Phase
    Ueda, Ryuta
    Sugiura, Tadao
    Kume, Shinichiro
    Ichikawa, Akihiko
    Larsen, Steven
    Miyoshi, Hideaki
    Hiramatsu, Hiroaki
    Nagatsuka, Yasuko
    Arai, Fumihito
    Suzuki, Yasuo
    Hirabayashi, Yoshio
    Fukuda, Toshio
    Honda, Ayae
    PLOS ONE, 2013, 8 (07):
  • [50] Virus Enrichment for Single Virus Infection by Using 3D Insulator Based Dielectrophoresis
    Masuda, Taisuke
    Maruyama, Hisataka
    Honda, Ayae
    Arai, Fumihito
    PLOS ONE, 2014, 9 (06):