Haemodynamic and metabolic response to endovascular repair of infra-renal aortic aneurysms

被引:60
|
作者
Baxendale, BR
Baker, DM
Hutchinson, A
Chuter, TAM
Wenham, PW
Hopkinson, BR
机构
[1] UNIV NOTTINGHAM HOSP,QUEENS MED CTR,DEPT VASC SURG,NOTTINGHAM NG7 2UH,ENGLAND
[2] UNIV CALIF SAN FRANCISCO,DIV VASC SURG,SAN FRANCISCO,CA 94143
关键词
surgery; vascular; arteries; aorta; cardiovascular system; effects; metabolism; lactate;
D O I
10.1093/bja/77.5.581
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have examined whether or not endovascular insertion of a bifurcated aorto-iliac graft resulted in greater intraoperative haemodynamic and metabolic stability than that achieved during conventional open graft placement. We studied 20 patients prospectively during surgery for asymptomatic infra-renal aortic aneurysm. All patients received the same anaesthetic technique. Haemodynamic data were collected continuously using indwelling radial artery and pulmonary artery catheters, allowing calculation of mean arterial pressure (MAP), cardiac output (CO) and systemic vascular resistance (SVR). Blood samples were obtained for measurement of serum lactate concentrations. Variables were compared within each group before and after specific critical events, namely occlusion of femoral or aortic blood flow, or both, and sequential reperfusion of each lower limb. Patients undergoing open repair showed significant changes in CO, MAP and SVR related to aortic cross-clamping and lower limb reperfusion, and a significant increase in blood lactate concentration after distal tissue reperfusion. The only significant changes during endovascular repair were a transient increase in SVR secondary to application of the femoral artery clamps, and sequential decreases when each limb was reperfused. Endovascular aneurysm repair imposed significantly less intraoperative haemodynamic and metabolic stress on the patient compared with conventional open surgery.
引用
收藏
页码:581 / 585
页数:5
相关论文
共 50 条
  • [1] Comments regarding 'Local Anaesthesia for Endovascular Repair of Infra-Renal Aortic Aneurysms'
    Varty, K.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 42 (04) : 474 - 474
  • [2] Endovascular repair for infra-renal aortic aneurysms with supra-renal fixation endoprosthesis: Results and outcomes
    Soares, Rafael de Athayde
    Amaro, Kaline
    Nasser, Ana Isabel
    Cury, Marcus Vinicius Martins
    Nakamura, Edson Takamitsu
    Pedrosa, Keityane de Lima
    Sacilotto, Roberto
    VASCULAR, 2024,
  • [3] Infra-renal abdominal aortic aneurysms
    Castier, Yves
    SANG THROMBOSE VAISSEAUX, 2011, 23 (07): : 348 - 359
  • [4] Concurrent Endovascular Repair of Extensive Thoracic Aortic and Infra-renal Aorto-iliac Aneurysms
    Joseph, George
    Janakiraman, Ezhilan
    Subban, Vijayakumar
    Jamesraj, Jacob
    Mullasari, Ajit S.
    HEART LUNG AND CIRCULATION, 2012, 21 (12): : 803 - 805
  • [5] Endovascular repair of abdominal aortic aneurysms (AAA) with short and/or angulated necks: infra-renal sealing is not a safe option
    Cross, J.
    Simring, D.
    Raja, J.
    Hague, J.
    Agu, O.
    Ivancev, K.
    Harris, P.
    Richards, T.
    BRITISH JOURNAL OF SURGERY, 2011, 98 : 7 - 7
  • [6] Large infra-renal abdominal aortic aneurysms: endovascular vs. open repair - single centre experience
    Chan, Y. C.
    Morales, J. P.
    Gulamhuseinwala, N.
    Sabharwal, T.
    Carmichael, M.
    Thomas, S.
    Carrell, T. W. G.
    Reidy, J. F.
    Taylor, P. R.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2007, 61 (03) : 373 - 378
  • [7] Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It
    Machado, Rui
    Dias Ferreira, Vitor Miguel
    Loureiro, Luis
    Goncalves, Joao
    Oliveira, Pedro
    Almeida, Rui
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 31 (06) : 415 - 421
  • [8] Endovascular repair of abdominal aortic aneurysms (AAA) outside manufacturers instructions for use: Infra-renal sealing is not a safe option
    Cross, J.
    Amiri, N.
    Fung, C.
    Harris, P.
    Richards, T.
    BRITISH JOURNAL OF SURGERY, 2011, 98 : 212 - 213
  • [9] A study on the patency of the inferior mesenteric and lumbar arteries in the incidence of endoleak following endovascular repair of infra-renal aortic aneurysms
    Walker, SR
    Halliday, K
    Yusuf, SW
    Davidson, I
    Whitaker, SC
    Gregson, RHS
    Hopkinson, BR
    CLINICAL RADIOLOGY, 1998, 53 (08) : 593 - 595
  • [10] Rupture of infra-renal aortic aneurysm after endovascular repair: A series from EUROSTAR registry
    Fransen, GAJ
    Vallabhaneni, SR
    van Marrewijk, CJ
    Laheij, RJF
    Harris, PL
    Buth, J
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 26 (05) : 487 - 493