Endovascular repair for infra-renal aortic aneurysms with supra-renal fixation endoprosthesis: Results and outcomes

被引:1
|
作者
Soares, Rafael de Athayde [1 ]
Amaro, Kaline [1 ]
Nasser, Ana Isabel [1 ]
Cury, Marcus Vinicius Martins [1 ]
Nakamura, Edson Takamitsu [1 ]
Pedrosa, Keityane de Lima [1 ]
Sacilotto, Roberto [1 ]
机构
[1] Hosp Serv Publ Estadual Sao Paulo, Div Vasc & Endovasc Surg, Barao de Jaceguai St 908,Postal Code 04606-000, BR-04029000 Sao Paulo, Brazil
关键词
Aortoiliac aneurysm; endografts; supra-renal fixation; endoleaks; EVAR TRIAL 1; STENT-GRAFTS; ZENITH ALPHA; DILATATION; ENDOGRAFT; EXCLUDER; NECK;
D O I
10.1177/17085381241264381
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: The main objective of this paper is to evaluate the outcomes regarding endoleaks, reinterventions, and death related to aneurysm complications in patients submitted to endovascular repair (EVAR) for abdominal aortoiliac aneurysm (AAA) using Endurant II (Medtronic) and Zenith Flex (Cook) endografts. Methods: This was a prospective, consecutive cohort study of patients with AAA who underwent EVAR with the use of Endurant II stent graft and Zenith Flex endograft. Results: A total of 156 patients submitted to EVAR were evaluated. The perioperative mortality was 5.1%, 8 patients. The median clinical follow-up period was 760 +/- 80 days. There were 28 patients (17.9%) submitted to urgent repair of the aneurysm (symptomatic expansion or rupture) and 128 patients (82.1%) submitted to elective repair. There were 36 cases (23.1%) of later endoleak and most of them are Type II endoleaks (21 patients, 13.4%). There were 12 cases of Type I endoleak. Moreover, regarding limb graft occlusion (LGO), there were 9 patients (5.8%). The overall survival rate in Kaplan-Meier analysis at 720 days was 84.8% in the total cohort. The freedom from reintervention rate in Kaplan-Meier analysis at 720 days was 92.7% in the total cohort. The linear regression analysis for survival rates showed that chronic kidney disease (p = .03; hazard ratio (HR) = 2.82, CI = 1.07-4.44) was the only factor related to poorer survival rates in both univariate and multivariate analyses. The linear regression analysis showed that the presence of endoleaks (p < .001, HR = 6.69, CI = 2.26-8.48) and limb graft occlusion (p < .001, HR = 8.02, CI = 1.60-9.99) were related to reintervention in both univariate and multivariate analyses. Conclusion: In this present study, supra-renal fixation endograft devices were safe and efficient in treating AAA, with satisfactory results and no renal compromise. The linear regression analysis showed that the presence of endoleaks and limb graft occlusion were related to higher reintervention rates in both univariate and multivariate analyses.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Adverse renal outcomes following endovascular or open repair of infra-renal and supra-renal abdominal aortic aneurysms: a systematic review and meta-analysis
    Tsai, J.
    Brown, T.
    Pouncey, A.
    Powell, J.
    Bicknell, C.
    BRITISH JOURNAL OF SURGERY, 2023, 110
  • [2] Haemodynamic and metabolic response to endovascular repair of infra-renal aortic aneurysms
    Baxendale, BR
    Baker, DM
    Hutchinson, A
    Chuter, TAM
    Wenham, PW
    Hopkinson, BR
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (05) : 581 - 585
  • [3] Comments regarding 'Local Anaesthesia for Endovascular Repair of Infra-Renal Aortic Aneurysms'
    Varty, K.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 42 (04) : 474 - 474
  • [4] Infra-renal abdominal aortic aneurysms
    Castier, Yves
    SANG THROMBOSE VAISSEAUX, 2011, 23 (07): : 348 - 359
  • [5] Concurrent Endovascular Repair of Extensive Thoracic Aortic and Infra-renal Aorto-iliac Aneurysms
    Joseph, George
    Janakiraman, Ezhilan
    Subban, Vijayakumar
    Jamesraj, Jacob
    Mullasari, Ajit S.
    HEART LUNG AND CIRCULATION, 2012, 21 (12): : 803 - 805
  • [6] Supra- and Infra-Renal Aortic Neck Diameter Increase after Endovascular Repair of a Ruptured Abdominal Aortic Aneurysm
    van der Riet, Claire
    Schuurmann, Richte C. L.
    Karelis, Angelos
    Suludere, Mehmet A.
    van Harten, Meike J.
    Sonesson, Bjoern
    Dias, Nuno V.
    de Vries, Jean-Paul P. M.
    Dijkstra, Martijn L.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [7] Endovascular repair of abdominal aortic aneurysms (AAA) with short and/or angulated necks: infra-renal sealing is not a safe option
    Cross, J.
    Simring, D.
    Raja, J.
    Hague, J.
    Agu, O.
    Ivancev, K.
    Harris, P.
    Richards, T.
    BRITISH JOURNAL OF SURGERY, 2011, 98 : 7 - 7
  • [8] Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It
    Machado, Rui
    Dias Ferreira, Vitor Miguel
    Loureiro, Luis
    Goncalves, Joao
    Oliveira, Pedro
    Almeida, Rui
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 31 (06) : 415 - 421
  • [9] Large infra-renal abdominal aortic aneurysms: endovascular vs. open repair - single centre experience
    Chan, Y. C.
    Morales, J. P.
    Gulamhuseinwala, N.
    Sabharwal, T.
    Carmichael, M.
    Thomas, S.
    Carrell, T. W. G.
    Reidy, J. F.
    Taylor, P. R.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2007, 61 (03) : 373 - 378
  • [10] Endovascular repair of abdominal aortic aneurysms (AAA) outside manufacturers instructions for use: Infra-renal sealing is not a safe option
    Cross, J.
    Amiri, N.
    Fung, C.
    Harris, P.
    Richards, T.
    BRITISH JOURNAL OF SURGERY, 2011, 98 : 212 - 213