Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients

被引:36
|
作者
Paarmann, H. [1 ]
Groesdonk, H. V. [1 ,3 ]
Sedemund-Adib, B. [1 ]
Hanke, T. [2 ]
Heinze, H. [1 ]
Heringlake, M. [1 ]
Schoen, J. [1 ]
机构
[1] Med Univ Lubeck, Dept Anesthesiol, D-23538 Lubeck, Germany
[2] Med Univ Lubeck, Dept Cardiac & Thorac Vasc Surg, D-23538 Lubeck, Germany
[3] Univ Saarland, Dept Cardiac & Thorac Vasc Surg, D-6650 Homburg, Germany
关键词
cardiac surgery; haemodynamic monitoring; pressure recorded analytical method; pulmonary arterial thermodilution; pulse-contour analysis; WAVE-FORM ANALYSIS; PULSE CONTOUR ANALYSIS; DOPPLER-ECHOCARDIOGRAPHY; VOLUME; TEMPERATURE; DECREASES; ACCURACY; SYSTEM; BYPASS;
D O I
10.1093/bja/aeq372
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Pulse-contour analysis method (PCM) cardiac output (CO) monitors are increasingly used for CO monitoring during anaesthesia and in the critically ill. Very recently, several systems have been introduced that do not need calibration; among them the pressure recording analytical method (PRAM). Sparse data comparing the accuracy of the PRAM-CO with conventional thermodilution CO (ThD-CO) in cardiac surgery patients are available. Methods. In this prospective comparison study, paired CO measurements with a pulmonary artery catheter and a PRAM monitoring set were obtained 20-30 min apart (t1, t2) in 23 extubated patients on the first postoperative day after cardiac surgery. Data were analysed by the Bland-Altman method. Results. A total of 46 paired CO measurements (23 for each interval) were collected. The Bland-Altman analysis showed a mean difference (bias) of 0.0 litre min(-1) and limits of agreement (1.96 SD) of 4.53 to -4.54 litre min(-1) [upper 95% confidence interval (CI), 3.26-5.80; lower 95% CI, -5.8 to -3.27]. The percentage error (1.96 SD/mean of the reference method) was 87%. Conclusions. These results question the reliability of the PRAM technology for the determination of CO in postoperative cardiac surgery patients.
引用
收藏
页码:475 / 481
页数:7
相关论文
共 50 条
  • [41] Lithium dilution versus thermodilution cardiac output measurement in cardiac surgery patients
    Young, CC
    Garcia-Rodriguez, CR
    Cassell, C
    El-Moalem, H
    Mark, JB
    [J]. ANESTHESIOLOGY, 2000, 93 (3A) : U166 - U166
  • [42] Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model
    Rupérez, M
    López-Herce, J
    García, C
    Sánchez, C
    García, E
    Vigil, D
    [J]. PEDIATRIC CARDIOLOGY, 2004, 25 (02) : 119 - 123
  • [43] CARDIAC-OUTPUT MEASUREMENT - LACK OF AGREEMENT BETWEEN THERMODILUTION AND THORACIC ELECTRIC BIOIMPEDANCE IN 2 CLINICAL SETTINGS
    ATALLAH, MM
    DEMAIN, AD
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (03) : 182 - 185
  • [44] Beat-by-beat monitoring of cardiac output with pressure recording analytical method
    Scolletta, S
    Giomarelli, P
    Biagioli, B
    [J]. ANAESTHESIA, PAIN, INTENSIVE CARE AND EMERGENCY MEDICINE - APICE 19, 2005, : 425 - 436
  • [45] Comparison Between Cardiac Output Measured by the Pulmonary Arterial Thermodilution Technique and that Measured by the Femoral Arterial Thermodilution Technique in a Pediatric Animal Model
    M. Rupérez
    J. López-Herce
    C. García
    C. Sánchez
    E. García
    D. Vigil
    [J]. Pediatric Cardiology, 2004, 25 : 119 - 123
  • [46] Thermodilution cardiac output measurements are accurate in patients with pulmonary hypertension
    Yung, GL
    Fletcher, CC
    Channick, RN
    Knowiton, KU
    Johnson, FW
    Kinninger, K
    Fedullo, PF
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A156 - A156
  • [47] Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
    Goedje, O
    Hoeke, K
    Lichtwarck-Aschoff, M
    Faltchauser, A
    Lamm, P
    Reichart, B
    [J]. CRITICAL CARE MEDICINE, 1999, 27 (11) : 2407 - 2412
  • [48] CARDIAC OUTPUT ESTIMATION BY A THERMODILUTION METHOD INVOLVING INTRAVASCULAR HEATING AND THERMISTOR RECORDING
    BARANKAY, T
    JANCSO, T
    NAGY, S
    PETRI, G
    [J]. ACTA PHYSIOLOGICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1970, 38 (2-3): : 167 - &
  • [49] Cardiac output measurement by pulse dye densitometry: Comparison with pulmonary artery thermodilution in post-cardiac surgery patients
    Kroon M.
    Groeneveld A.B.J.
    Smulders Y.M.
    [J]. Journal of Clinical Monitoring and Computing, 2005, 19 (6) : 395 - 399
  • [50] Cardiac Output Estimation by Multi-Beat Analysis of Arterial Blood Pressure Waveform versus Continuous Pulmonary Artery Thermodilution in Post Cardiac Surgery Intensive Care Unit Patients
    Khanna, Ashish K.
    Sands, Lauren E.
    Nosow, Lillian M.
    Saha, Amit
    Marchant, Bryan E.
    [J]. ANESTHESIA AND ANALGESIA, 2021, 132 (5S_SUPPL): : 340 - 341