Effect of sample preparation procedure on standardless wavelength dispersive X-ray fluorescence analysis of plant samples

被引:4
|
作者
Orlic, Jovana [1 ]
Grzetic, Ivan [1 ]
Ilijevic, Konstantin [1 ]
机构
[1] Univ Belgrade, Fac Chem, Studentski Trg 12-16, Belgrade 11000, Serbia
关键词
Systematic error; Pressed pellets; Green chemistry; Fundamental parameters; WDXRF; multielemental analysis; TRACE-ELEMENTS; QUANTITATIVE-DETERMINATION; PORTABLE-XRF; SPECTROMETRY; QUANTIFICATION; PERFORMANCE; POLLUTION; CELLULOSE; MATRICES; NEEDLES;
D O I
10.1016/j.sab.2021.106258
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
XRF (X-ray fluorescence analysis) has been applied as the method for analysis of plant samples, but not in its full potential. This method would be highly suitable for monitoring programs and screening studies. A simple sample preparation procedure makes this technique time and cost-effective, although the absence of adequate calibration standards for some analyzed matrices can be a significant limiting factor. Nevertheless, this obstacle can be overcome by the development of the so-called "standardless method" approach. It is important to explore the possibilities and limitations of such method applied to an analysis of plant materials. The accuracy of XRF analysis is highly dependent on the physical characteristics of the sample, which can be significantly affected by the sample preparation procedure. Variations of 3 crucial sample preparation parameters: the mass of the samples (from 1 to 5 g), binder ratio (from 0 to 25% of wax), and pressing pressure (from 10 to 25 t) were tested on needles obtained from two widespread conifer species: Pinus nigra and Abies alba. For most elements, the correlation between the concentration and the change of the binder ratio was statistically significant, while there was no statistically significant correlation between the concentration and the change of the pellet mass and applied pressure. For both types of needles, an estimated systematic error was always higher than a random error. The difference between two types of errors has been higher among samples with different wax content than in samples with different pellet mass, while the variation of applied pressure did not introduce any significant systematic error. On average the change of wax content inflated the value of systematic error by 18 and 13% for the pine and fir needle samples (respectively), while the change of the sample mass has introduced systematic error in lesser extent, on average it was 11% for pine needles and 10% for fir needle samples. The change of pelletizing pressure affected the results by only 3.9% for both conifer needles.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] ON PREPARATION OF SILICATE SAMPLES FOR X-RAY FLUORESCENCE ANALYSIS
    WILLGALL.A
    SCHNEIDE.G
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1969, 246 (02): : 115 - &
  • [22] ON PREPARATION OF MINERAL SAMPLES FOR X-RAY FLUORESCENCE ANALYSIS
    STAATS, G
    BRUCK, H
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1970, 250 (05): : 289 - &
  • [23] Wavelength-dispersive x-ray fluorescence detector
    Kirkland, J.P.
    Kovantsev, V.E.
    Dozier, C.M.
    Gilfrich, J.V.
    Gibson, W.M.
    Xiao, Qi-Fan
    Umezawa, K.
    Review of Scientific Instruments, 1995, 66 (2 pt 2):
  • [24] Preparation of Thin Films for Elemental Analysis of Nail Polish by Wavelength Dispersive X-Ray Fluorescence Spectroscopy
    McWilliams, Andrea C.
    Martin, Al A.
    Levine, Michael A.
    Levine, Keith E.
    Felder, Lauren
    Young, Daniel J.
    Harrington, James M.
    ANALYTICAL LETTERS, 2015, 48 (13) : 2122 - 2135
  • [25] Multielement analysis of soil and plant species using wavelength-dispersive X-ray fluorescence spectrometry
    Krishna, Keshav A.
    Mohan, Rama K.
    Dasaram, B.
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2013, 90 (11) : 2081 - 2087
  • [26] Energy dispersive X-ray fluorescence analysis of samples of the Nigerian Zircons
    Siyanbola, WO
    Fasasi, AY
    Funtua, II
    Fasasi, MK
    Tubosun, IA
    Pelemo, DA
    Adesiyan, TA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 426 - 432
  • [27] Effect of the conditions of sample preparation for x-ray fluorescence analysis on the effect of microabsorption heterogeneity
    Smagunova, A. N.
    Potapov, L. A.
    Ondar, U. V.
    Pan'kov, S. D.
    Rozova, O. F.
    Polyakova, S. V.
    Kozlov, V. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (08) : 723 - 729
  • [28] Effect of the conditions of sample preparation for x-ray fluorescence analysis on the effect of microabsorption heterogeneity
    Smagunova, A.N.
    Potapov, L.A.
    Ondar, U.V.
    Pan'Kov, S.D.
    Rozova, O.F.
    Polyakova, S.V.
    Kozlov, V.A.
    Journal of Analytical Chemistry, 2008, 63 (08): : 723 - 729
  • [29] Effect of the conditions of sample preparation for x-ray fluorescence analysis on the effect of microabsorption heterogeneity
    A. N. Smagunova
    L. A. Potapov
    U. V. Ondar
    S. D. Pan’kov
    O. F. Rozova
    S. V. Polyakova
    V. A. Kozlov
    Journal of Analytical Chemistry, 2008, 63 : 723 - 729
  • [30] Simple procedure for nutrient analysis of coffee plant with energy dispersive X-ray fluorescence spectrometry (EDXRF)
    Tezotto, Tiago
    Favarin, Jose Laercio
    Neto, Ana Paula
    Gratao, Priscila Lupino
    Azevedo, Ricardo Antunes
    Mazzafera, Paulo
    SCIENTIA AGRICOLA, 2013, 70 (04): : 263 - 267