CdZnTe detector as an x-ray spectrometer

被引:1
|
作者
Miyajima, S [1 ]
Sakuragi, H [1 ]
Matsumoto, M [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Course Hlth Sci, Suita, Osaka 5650871, Japan
关键词
x-ray spectra; CdZnTe detector; tailing; carrier trapping; Hecht equation; EGS4;
D O I
10.1117/12.430925
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we evaluated a CdZnTe (CZT) detector as an x-ray spectrometer. The output of the semiconductor detector is basically distorted due to the processes of energy deposition, charge generation and pulse processing. In addition, the distortion due to the charge transport process must be taken into account when using a CZT detector. First, we calculated response functions of the CZT detector using the EGS4. In the code, the Hecht equation was utilized to deal with the trapping of charge carriers during charge transport. The parameters in the equation, mean free, path of charge carriers, were determined to make the calculated response functions the same as the measured response to mono-energetic gamma-rays. Secondly, we corrected x-ray spectra using the calculated response functions. The stripping method was employed in the correction procedure. The results indicate that a CZT detector is useful in x-ray spectrometry with the proper corrections.
引用
收藏
页码:148 / 155
页数:8
相关论文
共 50 条
  • [31] The X-ray spectrometer
    不详
    [J]. NATURE, 1915, 94 : 199 - 200
  • [32] Test of a High Throughput Detector on the X-ray Crystal Spectrometer of the EAST
    Lu Bo
    Shi Yuejiang
    Wang Fudi
    Wan Baonian
    Bitter, Manfred
    Hill, Kenneth W.
    Lee, Sang-gon
    Li Yingying
    Fu Jia
    Zhang Jizong
    Xu Jingcui
    Shen Yongcai
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2013, 15 (02) : 97 - 100
  • [33] Test of a High Throughput Detector on the X-ray Crystal Spectrometer of the EAST
    吕波
    石跃江
    王福地
    万宝年
    Manfred BITTER
    Kenneth W HILL
    Sanggon LEE
    李颖颖
    符佳
    张继宗
    徐经翠
    沈永才
    [J]. Plasma Science and Technology., 2013, 15 (02) - 100
  • [34] Shaping amplifier for soft X-ray spectrometer with a silicon drift detector
    Tuboltsev, Yu. V.
    Chichagov, Yu. V.
    Bogdanov, A. A.
    Kantor, M. Yu.
    Sidorov, A. V.
    [J]. ST PETERSBURG POLYTECHNIC UNIVERSITY JOURNAL-PHYSICS AND MATHEMATICS, 2023, 16 (01): : 438 - 443
  • [35] Characterising a Si(Li) detector element for the SIXA X-ray spectrometer
    Tikkanen, T
    Kraft, S
    Scholze, F
    Thornagel, R
    Ulm, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 390 (03): : 329 - 335
  • [36] X-RAY FLUORESCENT SPECTROMETER WITH LINEAR POSITION-SENSITIVE DETECTOR
    DOLGIH, VE
    CHERKASHENKO, VM
    KURMAEV, EZ
    GOGANOV, DA
    OVCHINNIKOV, EK
    YARMOSHENKO, YM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 224 (1-2): : 117 - 119
  • [37] AN X-RAY SPECTROMETER WITH A POSITION-SENSITIVE WIRE DETECTOR (PSD)
    EBEL, H
    MANTLER, M
    GURKER, N
    WERNISCH, J
    [J]. X-RAY SPECTROMETRY, 1983, 12 (01) : 47 - 49
  • [38] Test of a High Throughput Detector on the X-ray Crystal Spectrometer of the EAST
    吕波
    石跃江
    王福地
    万宝年
    Manfred BITTER
    Kenneth W. HILL
    Sang-gon LEE
    李颖颖
    符佳
    张继宗
    徐经翠
    沈永才
    [J]. Plasma Science and Technology, 2013, (02) : 97 - 100
  • [40] Large-area CdZnTe thick film based array X-ray detector
    Gao, Xiuying
    Sun, Hui
    Yang, Dingyu
    Wangyang, Peihua
    Zhang, Chaofu
    Zhu, Xinghua
    [J]. VACUUM, 2021, 183