Determination of Polychlorinated Biphenyls in Marine Sediments by Ultrasound-Assisted Isolation and Dispersive Liquid-Liquid Microextraction and Gas Chromatography-Mass Spectrometry

被引:17
|
作者
Kuzukiran, Ozgur [1 ]
Yurdakok-Dikmen, Begum [2 ]
Filazi, Ayhan [2 ]
Sevin, Sedat [2 ]
Aydin, Farah Gonul [2 ]
Tutun, Hidayet [3 ]
机构
[1] Vet Control Cent Res Inst, Etlik, Turkey
[2] Ankara Univ, Dept Pharmacol & Toxicol, Fac Vet Med, Irfan Bastug St, TR-06110 Ankara, Turkey
[3] Mehmet Akif Ersoy Univ, Dept Pharmacol & Toxicol, Fac Vet Med, Burdur, Turkey
关键词
Gas chromatography-mass spectrometry; microextraction; polychlorinated biphenyls; sediments; ultrasound; POLYCYCLIC AROMATIC-HYDROCARBONS; PERSISTENT ORGANIC POLLUTANTS; EMULSIFICATION-MICROEXTRACTION; ORGANOCHLORINE PESTICIDES; WATER SAMPLES; EXTRACTION; PCBS; SOLIDIFICATION; DROPLET; SOXHLET;
D O I
10.1080/00032719.2016.1151890
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method is reported to determine polychlorinated biphenyls (PCBs) in marine sediments using ultrasound-assisted extraction and dispersive liquid-liquid microextraction with gas chromatography-mass spectrometry. To optimize the method, acetone, acetonitrile, and methanol were characterized for extraction from the sediments. Acetone provided the highest yield. A lower-density solvent system was utilized with isooctane and acetone, and the upper solvent was characterized by gas chromatography-mass spectrometry. The optimized procedure was validated. Sediments were fortified with PCBs 28, 52, 101, 118, 138, 153, and 180 at six concentrations from 0.25 to 8.0 ng g(-1) and used to prepare matrix-matched calibration curves. Samples were analyzed using this optimized procedure. The linearity was satisfactory in all cases, with correlation coefficients from 0.9989 to 0.9995. The limits of detection and quantification were from 0.021 to 0.057 ng g(-1) and 0.069 to 0.190 ng g(-1), respectively. The recovery values at three fortified concentrations were 90.07-100.4% and the relative standard deviations were less than 7.6%. The reported extraction method uses a low-density, low-toxicity solvent; a sample syringe as the extraction device; and does not require additional purification after extraction from sediment. The protocol is sensitive, convenient, and ecofriendly and was used to determine PCBs in marines with satisfactory results.
引用
收藏
页码:2525 / 2536
页数:12
相关论文
共 50 条
  • [41] Determination of Seven Antidepressants in Pericardial Fluid by Means of Dispersive Liquid-Liquid Microextraction and Gas Chromatography-Mass Spectrometry
    Cabarcos-Fernandez, P.
    Tabernero-Duque, M. J.
    Alvarez-Freire, I
    Bermejo-Barrera, A. M.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2022, 46 (02) : 146 - 156
  • [42] Comparison of hollow fiber liquid-phase microextraction and ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction for the determination of drugs of abuse in biological samples by gas chromatography-mass spectrometry
    Meng, Liang
    Zhang, Wenwen
    Meng, Pinjia
    Zhu, Binling
    Zheng, Kefang
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 989 : 46 - 53
  • [43] Determination of ultraviolet filters in water samples by vortex-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry
    Zhang, Yufeng
    Lee, Hian Kee
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1249 : 25 - 31
  • [44] Up-and-down-shaker-assisted dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry for the determination of fungicides in wine
    Chu, Shang-Ping
    Tseng, Wan-Chi
    Kong, Po-Hsin
    Huang, Chun-Kai
    Chen, Jung-Hsuan
    Chen, Pai-Shan
    Huang, Shang-Da
    [J]. FOOD CHEMISTRY, 2015, 185 : 377 - 382
  • [45] Screening method for rapid determination of polychlorinated biphenyls in transformer oil by liquid-liquid extraction and gas chromatography-mass spectrometry
    Toledo, Carla
    Valle, Luis
    Narvaez, Jessica
    Richter, Pablo
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2007, 18 (05) : 937 - 942
  • [46] Application of liquid-phase microextraction and gas chromatography-mass spectrometry for the determination of polychlorinated biphenyls in blood plasma
    Basheer, C
    Lee, HK
    Obbard, JP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) : 161 - 169
  • [47] Determination of polybrominated biphenyls in environmental water samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by high-performance liquid chromatography
    Wang, Xuemei
    Du, Tongtong
    Wang, Juan
    Kou, Haixia
    Du, Xinzhen
    [J]. MICROCHEMICAL JOURNAL, 2019, 148 : 85 - 91
  • [48] Simultaneous determination of cypermethrin and permethrin in pear juice by ultrasound-assisted dispersive liquid-liquid microextraction combined with gas chromatography
    Du, Jingjing
    Yan, Hongyuan
    She, Dandan
    Liu, Baomi
    Yang, Gengliang
    [J]. TALANTA, 2010, 82 (02) : 698 - 703
  • [49] Microwave-assisted extraction and dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry for isolation and determination of polycyclic aromatic hydrocarbons in smoked fish
    Ghasemzadeh-Mohammadi, Vahid
    Mohammadi, Abdorreza
    Hashemi, Maryam
    Khaksar, Ramin
    Haratian, Parivash
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1237 : 30 - 36
  • [50] Ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction for the simultaneous determination of 12 new antidepressants and 2 antipsychotics in whole blood by gas chromatography-mass spectrometry
    Chen, Xiujuan
    Zheng, Shuiqing
    Le, Jian
    Qian, Zheyuan
    Zhang, Runsheng
    Hong, Zhanying
    Chai, Yifeng
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 142 : 19 - 27