Multi-Target Control Strategy of DFIG Using Virtual Synchronous Generator Based on Extended Power Resonance Control under Unbalanced Power Grid

被引:3
|
作者
Sun, Dan [1 ]
Wang, Yangming [1 ]
Jiang, Tianlong [1 ]
Wang, Xiaohe [1 ]
Sun, Jun [2 ,3 ]
Nian, Heng [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
[2] State Key Lab Smart Grid Protect & Control, Nanjing 211106, Peoples R China
[3] NARI Grp Corp, Nanjing 211106, Peoples R China
关键词
doubly fed induction generator (DFIG); virtual synchronous generator (VSG); extended power; unbalanced grid voltage; second-order generalized integrator (SOGI); FED-INDUCTION-GENERATOR; OPERATION;
D O I
10.3390/en13092232
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Virtual synchronous generator control is considered as an effective solution to optimize the frequency response characteristics of doubly fed induction generator. However, due to the insufficient control bandwidth of the original virtual synchronous generator, it has little control effect over the oscillating components of the power caused by the unbalanced grid voltage. Therefore, long-term unbalanced voltage will cause a series of problems, such as distortion of stator and rotor currents, as well as oscillations of power and electromagnetic torque, which seriously affect the power quality and the operating performance of the doubly fed induction generator. To solve these problems, the concept of extended power is introduced, and the second-order generalized integrator-based resonant controller is used to control the extended power and traditional power. Control targets of the extended power method are discussed and extended, so that the doubly fed induction generator system using extended power resonant control-based virtual synchronous generator control can realize three different control targets under the unbalanced grid condition. The three control targets are: balanced and sinusoidal stator current, sinusoidal stator current and constant active power, and sinusoidal stator current and constant reactive power and electromagnetic torque. The three control targets can also be flexibly switched according to the real-time requirements of the grid with unbalanced voltage. The simulation results verify the effectiveness of the control method.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Research on Direct Power Control Strategy Based on Voltage Controlled Virtual Synchronous Generator
    Xu, Haizhen
    Yu, Changzhou
    Mao, Fubin
    Hu, Taotao
    Wu, Zelin
    Wang, Qinglong
    [J]. ELECTRONICS, 2021, 10 (19)
  • [42] Virtual synchronous generator fuzzy control strategy based on auxiliary inertial power regulation
    Zhang Y.-N.
    Cai M.-L.
    Xiang F.-Z.
    Hu S.-L.
    [J]. Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2021, 25 (07): : 98 - 106
  • [43] A Control Strategy for Smooth Power Tracking of a Grid-Connected Virtual Synchronous Generator Based on Linear Active Disturbance Rejection Control
    Zhang, Yaya
    Zhu, Jianzhong
    Dong, Xueyu
    Zhao, Pinchao
    Ge, Peng
    Zhang, Xiaolian
    [J]. ENERGIES, 2019, 12 (15)
  • [44] A Novel Direct Power Control for DFIG With Parallel Compensator Under Unbalanced Grid Condition
    Gao, Shuning
    Zhao, Haoran
    Gui, Yonghao
    Zhou, Dao
    Terzija, Vladimir
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (10) : 9607 - 9618
  • [45] Modeling and improvement of direct power control of DFIG under unbalanced grid voltage condition
    Zandzadeh, Mohammad Jafar
    Vahedi, Abolfazl
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 59 : 58 - 65
  • [46] Direct power control on the DFIG wind turbine under unbalanced grid voltage conditions
    Guo, Xiaoming
    He, Yikang
    He, Benteng
    Hu, Jiabing
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2008, 32 (13): : 86 - 91
  • [47] Virtual Synchronous Generator Control Under Unbalanced Voltage Condition
    Zhang, Xiaobin
    Shen, Jia
    Huang, Chenxi
    Li, Chengkai
    Li, Yue
    Xiao, Sige
    [J]. 2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 901 - 906
  • [48] Power Decoupling Control Strategy in Virtual Synchronous Generator With Improved Reactive Power Loop Based on Adaptive Virtual Impedance
    Li X.
    Lu L.
    Cheng L.
    Wang J.
    Lü Z.
    Li W.
    Gu W.
    [J]. Dianwang Jishu/Power System Technology, 2019, 43 (10): : 3752 - 3760
  • [49] Virtual Synchronous Generator Control Strategy of Grid-Forming Matrix Converter for Renewable Power Generation
    Zhang, Jianwei
    Wang, Huidong
    Liu, Guangchen
    Tian, Guizhen
    Rivera, Marco
    Wheeler, Patrick
    [J]. IEEE ACCESS, 2024, 12 : 106672 - 106684
  • [50] Research on Control Strategy of VIENNA Rectifier under Unbalanced Power Grid
    Xing, Kaiting
    Huang, Xiping
    Chen, Guitao
    Sun, Xiangdong
    [J]. 2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 2228 - 2232