Iso-NTCP dose escalation with image-guided adaptive radiation therapy (IGART) for localized carcinoma of the prostate

被引:0
|
作者
Song, W [1 ]
Schaly, B [1 ]
Bauman, G [1 ]
Battista, J [1 ]
Van Dyk, J [1 ]
机构
[1] London Hlth Sci Ctr, London Reg Canc Program, London, ON, Canada
关键词
D O I
10.1118/1.1997612
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the efficacy of various image‐guided target localization techniques to assist in the safe dose escalation for prostate cancer radiation therapy in the presence of geometric uncertainties. Method and Materials: Five prostate cancer patients were analyzed, retrospectively. All patients were planned with an 18MV six‐field conformal technique with a 10 mm margin and an initial prescription dose of 70 Gy in 35 fractions. For the dose escalation study, the prescription dose was increased from 50 Gy in 2 Gy increments until the rectum normal tissue complication probability (NTCP) reached the level equal to that of the plan NTCP (i.e., iso‐NTCP). The target localization techniques simulated were (1) laser alignment to external tattoo marks, (2) alignment to bony landmarks with daily portal images, and (3) alignment to the clinical target volume (CTV) with daily CT imaging. Techniques (1) and (3) were re‐simulated with a reduced margin of 5 mm to investigate further dose escalation. Results: The selection of the target localization technique was less critical on the treatment outcome when 10 mm margin was used. Reducing the margin size from 10 to 5 mm effectively decreased the NTCP by ∼60 % for all patients. For iso‐NTCP dose escalation, to our surprise, the average dose and TCP gain for the five patients were largest with the external tattoo technique (6.4 Gy and 7.5 %, respectively) followed by the daily CTV and the bony landmarks. The variability in gain across the five patients, however, was also largest with the tattoo registration technique and smallest with the daily CTV technique. Conclusion: Based on these data, the best dose escalation strategy is to combine margin reduction (for increased normal tissue sparing) with the use of the daily CTV technique to localize the target volume (for consistent dosimetric coverage and escalation). © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1935 / 1935
页数:1
相关论文
共 50 条
  • [21] Rectal dose variation during the course of image-guided radiation therapy of prostate cancer
    Chen, Lili
    Paskalev, Kamen
    Xu, Xiu
    Zhu, Jennifer
    Wang, Lu
    Price, Robert A.
    Hu, Wei
    Feigenberg, Steven J.
    Horwitz, Eric M.
    Pollack, Alan
    Ma, C. M. Charlie
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 198 - 202
  • [22] ASSESSMENT OF BIOCHEMICAL OUTCOME WITH INCREASING DOSE ESCALATION IN LOCALIZED PROSTATE CANCER (PCA) WITH PRECISION IMAGE-GUIDED RADIOTHERAPY (IGRT)
    Raziee, Hamid
    Murgic, Jure
    Pintilie, Melania
    Chung, Peter
    Menard, Cynthia
    Bayley, Andrew
    Warde, Padraig
    Gospodarowicz, Mary
    Bristow, Robert
    Catton, Charles
    Berlin, Alejandro
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S82 - S82
  • [23] Assessment of Biochemical Outcomes with Increasing Dose Escalation in Localized Prostate Cancer (PCa) Treated with Precision Image Guided Radiation Therapy (IGRT)
    Raziee, H.
    Murgic, J.
    Pintilie, M.
    Chung, P.
    Menard, C.
    Bayley, A.
    Gospodarowicz, M.
    Warde, P. R.
    Bristow, R. G.
    Catton, C. N.
    Berlin, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E228 - E229
  • [24] Multi-Fraction Dose Distributions for Image-Guided IMRT of Prostate: Impact on TCP and NTCP
    Battista, J.
    Johnson, C.
    Turnbull, D.
    Kempe, J.
    Bauman, G.
    Van Dyk, J.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [25] Dosimetric evaluation of image-guided radiation therapy for prostate cancer
    Shan, Guoping
    Hu, Wei
    Chen, Lili
    Price, Robert A.
    Ma, C-M Charlie
    [J]. MEDICAL DOSIMETRY, 2021, 46 (02) : 117 - 126
  • [26] Assessment of dose reconstruction errors in image-guided radiation therapy
    Zhong, Hualiang
    Weiss, Elisabeth
    Siebers, Jeffrey V.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03): : 719 - 736
  • [27] Late Genitourinary Toxicity Associated with Hypofractionated Adaptive Image-Guided Radiation Therapy for Prostate Cancer
    Agbahiwe, H. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S343 - S343
  • [28] Adaptive Image-Guided Radiation Therapy (AIGRT) for Hypo-Fractionated Prostate Cancer Treatment
    Li, T.
    Thongphiew, D.
    Zhu, X.
    Yin, F.
    Wu, Q.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Image-Guided Stereotactic Body Radiation Therapy for Clinically Localized Prostate Cancer: Preliminary Clinical Results
    Bolzicco, Giampaolo
    Favretto, Maria Silvia
    Scremin, Enrico
    Tambone, Carmelo
    Tasca, Andrea
    Guglielmi, Rosabianca
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (05) : 473 - 477
  • [30] THE RISK OF URINARY INCONTINENCE AFTER FIDUCIAL BASED IMAGE-GUIDED HIGH DOSE INTENSITY MODULATED RADIATION THERAPY FOR LOCALIZED PROSTATE CANCER
    Obedian, Edward
    Olsson, Carl A.
    Kapoor, Deepak A.
    Keane, John
    Zimberg, Shawn H.
    [J]. JOURNAL OF UROLOGY, 2009, 181 (04): : 762 - 762