Quantification of blood flow velocity of the internal carotid artery: a comparison between phase- Contrast MRI and Doppler Ultrasound

被引:0
|
作者
Safavi, Tahere Sadat [1 ]
Fatouraee, Nasser [1 ]
Soleimani, Effat [2 ]
机构
[1] Amirkabir Univ Technol, Dept Biomed Engn, Tehran, Iran
[2] Tarbiat Modares Univ, Dept Med Phys, Tehran, Iran
关键词
image processing; blood velocity profile; phase-contrast MRI; ultrasound; internal carotid artery;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Noninvasive techniques for quantifying the blood flow velocity profile of the internal carotid artery are clinically valuable. hi this study two modalities most frequently used for blood velocity estimation were compared. In the present study blood flow velocity waveform of the internal carotid artery of a healthy male subject was acquired using phase- contrast MRI and Doppler ultrasound modalities. The Doppler spectrum was denoised and maximum velocity envelope curve was extracted using an automatic MAT LAB program. Furthermore, the phase contrast MRI images were processes and the maximum velocity profile was extracted. The extremum values of two profiles as well as the area under the velocity curves were extracted and compared. Results of the present study showed that the overall pattern of the blood velocity waveforms obtained from two modalities were similar (R=0.84). However, Peak systolic, end diastolic and mean velocities resultant from two modalities have a difference of 7.48, 2.83 and 3.19 cm/s respectively. Our results demonstrated that there is a high correlation between blood velocities resulted from Doppler Ultrasound and Phase- contrast MRI and either techniques can he used for blood flow measurements in the internal carotid artery.
引用
收藏
页码:95 / 98
页数:4
相关论文
共 50 条
  • [21] Effect of Contrast Agents on Results of Doppler Ultrasound Measurement of Blood Flow Velocity
    Muravieva O.V.
    Bogdan O.P.
    Nafikova S.F.
    Muravieva, O.V. (olgak166@mail.ru), 1600, Springer Science and Business Media, LLC (50): : 44 - 49
  • [22] RELATIONSHIP BETWEEN CAROTID ARTERY DOPPLER FLOW VELOCITY AND EXTENT OF CORONARY ARTERY DISEASE
    Gunduz, Yasemin
    Akdemir, Ramazan
    Gunduz, Huseyin
    Varim, Perihan
    Ayhan, Lacin Tatli
    Cakar, Mehmet Akif
    Vatan, Mehmet Bulent
    Kilic, Harun
    PAKISTAN HEART JOURNAL, 2019, 52 (02): : 124 - 131
  • [23] COMPARISON OF CAROTID ARTERY BLOOD VELOCITY MEASUREMENTS BY VECTOR AND STANDARD DOPPLER APPROACHES
    Tortoli, Piero
    Lenge, Matteo
    Righi, Daniele
    Ciuti, Gabriele
    Liebgott, Herve
    Ricci, Stefano
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05): : 1354 - 1362
  • [24] PULSED DOPPLER - AN EVALUATION OF DIAMETER, BLOOD VELOCITY AND BLOOD-FLOW OF THE COMMON CAROTID-ARTERY IN PATIENTS WITH ISOLATED UNILATERAL STENOSIS OF THE INTERNAL CAROTID-ARTERY
    BENETOS, A
    SIMON, A
    LEVENSON, J
    LAGNEAU, P
    BOUTHIER, J
    SAFAR, M
    STROKE, 1985, 16 (06) : 969 - 972
  • [25] Intracerebral laser Doppler blood flow measurements compared to blood flow in porcine internal carotid artery
    Kirkeby, OJ
    Rise, IR
    JOURNAL OF CLINICAL NEUROSCIENCE, 1999, 6 (05) : 389 - 394
  • [26] Carotid Flow Volume Measurement in Doppler Ultrasound as a New Look at the Diagnosis of Internal Carotid Artery Stenosis
    Kaszczewski, Piotr
    Elwertowski, Micha
    Leszczynski, Jerzy
    Ostrowski, Tomasz
    Galazka, Zbigniew
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (05) : E162 - E162
  • [27] Intermittent drop in blood flow velocity in the internal carotid artery and its branches
    Samii, C
    Diehl, RR
    Berlit, P
    JOURNAL OF CLINICAL ULTRASOUND, 2002, 30 (02) : 98 - 102
  • [28] Differences between Doppler angle correction techniques for internal carotid artery velocity measurements
    Polak, JF
    Alessi, JM
    Mccauley, MA
    Bjorn, LA
    White, MC
    RADIOLOGY, 1998, 209P : 341 - 341
  • [29] FAILURE OF AUTOREGULATION OF CEREBRAL BLOOD-FLOW IN NEONATES STUDIED BY PULSED DOPPLER ULTRASOUND OF THE INTERNAL CAROTID-ARTERY
    JORCH, G
    JORCH, N
    EUROPEAN JOURNAL OF PEDIATRICS, 1987, 146 (05) : 468 - 472
  • [30] QUANTIFICATION OF CAROTID BLOOD-FLOW VELOCITY USING MR PHASE MAPPING
    FURST, G
    SITZER, M
    HOFER, M
    STEINMETZ, H
    HACKLANDER, T
    MULLER, E
    MODDER, U
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (05) : 688 - 696