CORVUS IMRT film dosimetry using novel GafChromic EBT film

被引:0
|
作者
Trichter, F
Trichter, S
机构
[1] St Barnabas Hosp, Livingston, NJ USA
[2] Cornell Univ, New York Presbyterian Hosp, Weill Med Ctr, New York, NY USA
关键词
D O I
10.1118/1.1999758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the new EBT GafChromic film for IMRT relative and absolute film dosimetry and to investigate its application for IMRT QA. Method and Materials: EBT GafChromic film (ISP, Wayne, NJ) was compared with EDR2 (Eastman Kodak, Rochester, NY) for IMRT treatment planning QA. The IMRT QA procedure was described previously (1). The IMRT treatment plans were generated on a Corvus (Nomos, NAS, Cranberry Township, PA) treatment planning system for a 25 cm × 25cm × 25cm phantom, using a 23MV photon beam (Siemens, Primus 23). The planning isodose distribution was compared with the measured isodose distribution in the transverse plane that included the isocenter. Film dosimetry was performed using a Vidar VXR‐16 Dosimetry Pro scanner (Vidar, Herndron, VA) and RIT 113(Colorado Springs, CO) software. Contour MSKCC software was used for dose overlays. Results: The EBT film scanning intensity on the Vidar scanner depends on film scanning direction. The intensity difference is 13%–20% between scans of the same film rotated by 90°. For film dosimetry this requires the H&D curve films and QA films to be scanned in the same direction. The isocenter dose difference between dosimetry in each direction is up to 2%, mixing scanning directions can cause a dose difference of 30%. The difference in dose value at the isocenter between the plan and EBT film was 1.6%–5.1%. Conclusion: The EBT provides quantitative 2D dose measurements in high gradient rapidly changing IMRT fields and has dosimetry accuracy comparable with EDR2. The film scanning direction is critical for absolute dose evaluation. Conflict of Interest: The EBT film for this research was provided by ISP Corporation. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2167 / 2167
页数:1
相关论文
共 50 条
  • [1] A single dose calibration method for IMRT QA film dosimetry using Gafchromic® EBT film
    Baker, J.
    Telivala, T.
    Reinstein, L.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2152 - 2152
  • [2] Proton Beam Dosimetry Using Gafchromic EBT Film
    Zhao, Li
    Das, I.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Comparison of the radio chromatic EBT film Dosimetry with EBT2 (Gafchromic) for IMRT Verification
    Schwedas, M.
    Howitz, S.
    Wiezorek, T.
    Wendt, T. G.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 105 - 105
  • [4] Optimization of IMRT QA with EBT gafchromic film
    Schneider, F.
    Polednik, M.
    Wolff, D.
    Delana, A.
    Lohr, F.
    Wenz, F.
    Menegotti, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S712 - S712
  • [5] Evaluation of GAFCHROMIC® EBT film for CyberKnife® dosimetry
    Wilcox, Ellen E.
    Daskalov, George M.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 1967 - 1974
  • [6] Gafchromic EBT film dosimetry in proton beams
    Zhao, Li
    Das, Indra J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10): : N291 - N301
  • [7] Evaluation of gafchromic EBT film for prostate IMRT verification
    Aziz, T.
    Budgell, G. J.
    Mackay, R. I.
    [J]. CLINICAL ONCOLOGY, 2007, 19 (03) : S24 - S24
  • [8] Scanning orientation effects on Gafchromic EBT film dosimetry
    Butson M.J.
    Cheung T.
    Yu P.K.N.
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2006, 29 (3): : 281 - 284
  • [9] Dosimetry of gamma chamber blood irradiator using Gafchromic EBT film
    Vandana, S.
    Shaiju, V. S.
    Sharma, S. D.
    Mhatre, S.
    Shinde, S.
    Chourasiya, G.
    Mayya, Y. S.
    [J]. APPLIED RADIATION AND ISOTOPES, 2011, 69 (01) : 130 - 135
  • [10] Ion beam dosimetry using Gafchromic EBT3 film
    Hassan, M. G.
    El-Saftawy, A. A.
    Soliman, B. A.
    Abdelrahman, M. M.
    Abdelmageed, K. E.
    Hassouba, M. A.
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2024, 130 (06):